My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2758
>
2300 - Underground Storage Tank Program
>
PR0541416
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2026 9:28:44 PM
Creation date
8/20/2025 11:39:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0541416
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0023733
FACILITY_NAME
SUNWEST CHEVRON
STREET_NUMBER
2758
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
Lodi
Zip
95242
APN
16646031
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2758 W Kettleman LN Lodi 95242
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />COUNTY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />12758 TOctober <br />Date: <br />SUNWEST CHEVRON <br />W KETTLEMAN LN, LODI <br />16, 2025 <br />19 <br />CA Code of Regulations <br />2010005 - ELD testing results sent to the board and the CUPA within 60 days of <br />❑ OUT ❑ R ❑ COS <br />2644.1(a)(5) <br />completion of the test <br />20 <br />CA Code of Regulations <br />2030056 - SIR Report submitted to the CUPA every 12 months <br />❑ OUT ❑ R ❑ COS <br />2646.10) <br />21 <br />CA Code of Regulations <br />2030064 - CUPA was notified within 48 hours prior to testing <br />❑ OUT ❑ R ❑ COS <br />2637, 2638(e), 2643(g) <br />22 <br />CA Code of Regulations <br />2030068 - Initial or triennial ELD testing conducted on UST system 1 000'of public <br />❑ OUT ❑ R ❑ COS <br />2640(e), 2644.1 <br />well <br />23 <br />CA Code of Regulations <br />2060001 - As -built plans for new installations and/or with the permit application <br />❑ OUT ❑ R ❑ COS <br />2635(e)(8) <br />have been submitted <br />24 <br />CA Code of Regulations <br />2030003 - Leak detection system maintains continuous monitoring that activates <br />❑ OUT ❑ R ❑ COS <br />2632(c), 2634(d), 2636(f) <br />an audible and visual alarm <br />25 <br />CA Code of Regulations <br />2030016 - Annular space of USTs are continuously monitored with an audible and <br />❑ OUT ❑ R ❑ COS <br />2631(g), 2632(c)(2) <br />visual alarm system (TCR 9d) <br />26 <br />CA Code of Regulations <br />2030017 - Piping out of UDC is fail-safe/shut down, UDC leak shuts off pump/flow, <br />❑ OUT ❑ R ❑ COS <br />2636(f)(4) <br />or tightness test (TCR 9d) <br />27 <br />CA Code of Regulations <br />2030018 - DW press piping is monitored with an audible/visual alarm or stops flow <br />❑ OUT ❑ R ❑ COS <br />2666(b)(2), 2636(f)(1) <br />at UDC (TCR 9d) <br />28 <br />CA Code of Regulations <br />2030043 - Leak detection equipment properly installed, calibrated, operated, and <br />■ OUT ❑ R ❑ COS <br />2638(a), 26410) <br />maintained (TCR 9d) <br />29 <br />CA Health and Safety <br />2060005 - UST system constructed with a mon system capable of detecting entry <br />❑ OUT ❑ R ❑ COS <br />Code 2636(a)(1), 25291 <br />into secondary containment <br />(b) <br />30 <br />CA Code of Regulations <br />2060015 - Leak detection equipment located so leak is detected at the earliest <br />❑ OUT ❑ R ❑ COS <br />2630(d), 2641(a) <br />possible opportunity (TCR 9d) <br />31 <br />CA Health and Safety <br />2030062 - Leak detection equipment has not been tampered with or disabled (TCR <br />❑ OUT ❑ R ❑ COS <br />Code 25299(a)(9) <br />9d) <br />32 <br />CA Code of Regulations <br />2030075 - E Gen System LLD detects 3 gph leak & restricts/shuts off flow or <br />❑ OUT ❑ R ❑ COS <br />2636(f), 2666(c), 2666(f) <br />activates and/vis alarm (TCR 9d) <br />33 <br />CA Health and Safety <br />2060022 - System has a mon system capable of detecting entry of haz sub or <br />❑ OUT ❑ R ❑ COS <br />Code 25290.2(d) <br />water into secondary containment <br />34 <br />CA Code of Regulations <br />2030034 - Tag/sticker on affixed monitoring equipment being certified, repaired, or <br />❑ OUT ❑ R ❑ COS <br />2638(f), 26410) <br />replaced <br />35 <br />CA Health and Safety <br />2030065 - Interstitial space of the UST is under constant VPH monitoring (TCR 9d) <br />■ OUT ❑ R ❑ COS <br />Code 25290.1(e) <br />36 <br />CA Health and Safety <br />2060023 - System has a mon system that can detect entry of haz sub liquid/vapor, <br />❑ OUT ❑ R ❑ COS <br />Code 25290.1(d) <br />or water into sec contain <br />37 <br />CA Code of Regulations <br />2030009 - Cathodic protection is installed/maintained as required, including <br />❑ OUT ❑ R ❑ COS <br />2635, 2636(b), 2662, <br />required documentation (TCR 9c) <br />2712 <br />38 <br />CA Code of Regulations <br />2030005 - SW tank continuous in tank leak detection test is functioning properly <br />❑ OUT ❑ R ❑ COS <br />2643(b)(3) <br />(TCR 9d) <br />39 <br />CA Code of Regulations <br />2030006 - Monthly 0.2 gph ATG test is being conducted and copies of test results <br />❑ OUT ❑ R ❑ COS <br />2643(b)(1) <br />are available (TCR 9d) <br />40 <br />CA Health and Safety <br />2060002 - SW UST system has monitoring system capable of detecting releases <br />❑ OUT ❑ R ❑ COS <br />Code <br />(TCR 9d) <br />41 <br />CA Code of Regulations <br />2030022 - Groundwater and/or vadose zone monitoring conducted, or site <br />❑ OUT ❑ R ❑ COS <br />2647, 2648, 2712(b)(4) <br />assessment maintained (TCR 9d) <br />42 <br />CA Code of Regulations <br />2030052 - .2 gph mthly or .1 gph yrly tests performed on piping, and .1 gph w/in 30 <br />❑ OUT ❑ R ❑ COS <br />2643(c), 2661(f) <br />days of repair (TCR 9d) <br />43 <br />CA Code of Regulations <br />2060012 - LLD installed on pressurized piping system (TCR 9d) <br />❑ OUT ❑ R ❑ COS <br />2636, 2643(c)(1), 2666(f) <br />44 <br />CA Code of Regulations <br />2030027 - LLD on SW press piping tests hrly, detects 3 gph leak, shuts down <br />❑ OUT ❑ R ❑ COS <br />2643(c)(1), 2666(c) <br />pump if leak or LLD fails (TCR 9d) <br />EHD - CUPA Inspection Report IS02 Page 2 of 5 FA0023733 PRO541416 4564779 10/16/2025 <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.