WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1904
>
2900 - Site Mitigation Program
>
PR0543660
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2026 1:21:57 PM
Creation date
8/25/2025 2:26:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0543660
PE
2960 - RWQCB LEAD AGENCY CLEAN UP SITE
FACILITY_ID
FA0024809
FACILITY_NAME
OXYCHEM STOCKTON
STREET_NUMBER
1904
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16302041
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
1904 W CHARTER WAY STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geosyntec <br /> consultants <br /> 4.3.2 Monitoring Well Construction <br /> Monitoring wells MW-5C and MW-7C will be constructed in accordance with standards <br /> presented in the San Joaquin County Well Standards. Each well will be constructed in the <br /> same general configuration as the well it is intended to replace.A schematic diagram depicting <br /> the anticipated construction details for wells MW-5C and MW-7C is presented on Figure 3. <br /> Once the hollow stem auger reaches final depth at each boring, the monitoring wells will be <br /> constructed through the hollow stem auger casing. One foot of sand will be placed at the <br /> bottom of the borehole below the well screen. MW-5C and MW-7C will both be constructed <br /> using 4-inch diameter, flush-threaded Schedule 80 polyvinyl chloride (PVC) casing, bottom <br /> caps and well screen (0.020-inch factory-slotted). Both wells will be screened within the <br /> shallow groundwater zone;well MW-5C will be screened from approximately 10 ft bgs to 25 <br /> ft bgs,and well MW-7C will be screened from approximately 12 ft bgs to 27 ft bgs. However, <br /> Geosyntec will specify the exact screen elevations during the installation,and may adjust these <br /> intervals based on the observed depths of coarse-grained materials and the depths of the <br /> underlying fine-grained clayey material assumed to represent the bottom of the shallow zone. <br /> To reduce the potential for cracking or root incursions at well joints, 10-foot sections of PVC <br /> riser and screen will be used where feasible to reduce the total number of joints, and the <br /> exterior of the joints may be reinforced using stainless steel clamps. <br /> Graded silica sand pack(#2/16 or similar) will be tremie-filled into the annular space across <br /> the screened interval of each monitoring well, extending two feet above the top of the screen. <br /> After the filter pack is installed and prior to placement of the bentonite seal,each well will be <br /> pre-developed by surging to settle the filter pack. During and after pre-development, a <br /> weighted tape will be used to monitor sand settlement. If settlement of the filter pack is <br /> observed, then additional filter pack material will be added to extend the filter pack two feet <br /> above the top of the well screen. A minimum of two feet of bentonite pellets will then be <br /> placed on top of the sand pack and hydrated a minimum of one-half hour before introducing <br /> additional backfill (i.e., grout) to provide a seal above the filter pack. Above the bentonite <br /> seal, a bentonite and neat cement grout mixture will be added using tremie pipe to fill the <br /> remainder of the borehole annulus to ground surface in accordance with applicable SJCEHD <br /> requirements. The borehole grout seal will be inspected after a 24-hour period and additional <br /> grout added, if needed, until firm grout is present at the ground surface. <br /> Both wells will be completed in accordance with SJCEHD requirements, and Geosyntec will <br /> coordinate with SJCEHD for inspection of well construction and grouting activities. A <br /> waterproof locking cap will be installed over each monitoring well within an appropriately- <br /> sized, traffic-rated, well box set in concrete. Additionally, the elevation and location of the <br /> north side of each well box and top of the PVC well casing will be surveyed by Morrow <br /> OxyChem-Stockton MW Replacement Work Plan 7.18.25 5 2025.07.18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.