Laserfiche WebLink
Ultimate Load by Standard FGS Anchor System Component for Selected Tank Diameter <br />Strap ult_load 25000lbf Turnbuckleult_load 26000lbf <br />IDtk 120 in <br />Wire_Ropeult_load 23000lbf Eye_Boltult_load 26000lbf <br />Set the allowable anchor point load at the FGS standard design values. This design anchor point <br />tension load value will meet or exceed a 3 to 1 FS for each individual anchoring system <br />component. <br />Allowable Anchor Point <br />Tension Load <br />Loada_allow 1261lbf IDtk 48in=if <br />5405lbf IDtk 72in=if <br />7508lbf IDtk 72in!if <br />1261lbf otherwise <br /> <br />Loada_allow 7508lbf <br />Anchor Strap Locations can be input below in any order in any row <br />The option is provided to input the anchor strap locations as 1) the distance from the tank end <br />OR 2) as the spacing between locations. <br />Method that will be <br />used to input <br />anchor locations <br />Aninput  Aninput "From Tank End" <br />Input Anchor Loc ations Fr om Tank End <br />Tank Buoyancy, Rotten Robbie No 69, <br />Manteca CA, dwg 17366-001, 10ft DWT <br />Date Printed: 9/7/2023 Page 31 of 46