Laserfiche WebLink
SHEET NUMBER: <br />SHEET CONTENTS: <br />PROJECT NUMBER:PROJECT DATE: <br />CONSULTANTS: <br />REVISIONS: <br />18-046 12-24-2020 <br />DEVELOPER: <br />CONTRACTOR: <br />PROJECT: <br />PROFESSIONAL SEALS: <br />1014 S. Airport Road <br />Manteca, California <br /> 95336 <br />1 <br />2 <br />Robinson Oil Corporation <br />955 Martin Ave. <br />Santa Clara, CA 95050 <br />Sacramento, CA 95827 <br />PH:(916) 455-6500 FAX:(916) 455-8100 <br />3090 Fite Circle, #104 <br />K12 Architects, Inc <br />CONVENIENCE STORE & <br />FUELING CANOPY <br />MANTECA <br />3 <br />4 <br />PLAN CHECK JAN. 12, 2023 <br />OWNER CHANGE MARCH 17, 2023 <br />PLAN CHECK AUGUST 17, 2023 <br />PLAN CHECK MARCH 29, 2024 <br />PLAN CHECK hzmt MAY 10, 2024 <br />5 PLAN CHECK hzmt MAY 31, 2024 <br />6 PLAN CHECK hzmt AUGUST 7, 2024 <br /> November 06, 2024 <br />8 PLAN CHECK hzmt OCT. 26, 2024 <br />7 PLAN CHECK hzmt SEPT. 26, 2024 <br />GENERAL FUEL SYSTEM NOTES <br />CONTRACTOR SHALL HAVE THE FOLLOWING LICENSES AT A MINIMUM: <br />GENERAL ENGINEERING "A" <br />HAZARDOUS MATERIAL SUBSTANCE HANDLING <br />CONTRACTOR SHALL HAVE AND MAINTIAN THE FOLLOWING INSURANCE: <br />PERMITS <br />EXCAVATE AS NECESSARY FOR THE INSTALLATION OF NEW SUMPS AND PIPING. <br />INSTALL EQUIPMENT AS LISTED IN EQUIPMENT LIST. <br />PIPING SYSTEMS SHALL BE TESTED AS FOLLOWS: <br />ALL CONDUIT SHALL BE 3/4"(MIN). MIN. BURIAL DEPTH OF 24" <br />1. <br />2. <br />3. <br />4. <br />5. <br />A. <br />B. <br />6. <br />7. <br />8. <br />1. <br />2. <br />3. <br />4. <br />SCOPE OF WORK <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />12. <br />13. <br />14. <br />15. <br />A. <br />B. <br />C. <br />D. <br />A.STEEL PIPING: <br />A.PETROLEUM PIPING TEST PROCEDURE: <br />1. <br />2.CONFIRM TESTING PROCEDURE WITH LOCAL AGENCIES PRIOR TO TESTING. <br />3.PRIMARY TESTING: <br />(1) <br />(2)BEFORE APPLYING PRESSURE, VERIFY THE FOLLOWING HAVE BEEN COMPLETED: <br />*VERIFY SHEAR VALVES ARE CLOSED. <br />*VERIFY THE BALL VALVE CLOSEST TO THE TURBINE IS CLOSED. <br />* <br />(3)PROCEDURES TO FOLLOW WHEN APPLYING PRESSURE: <br />* <br />* <br />* <br />* <br />*SYSTEM SHOULD BE KEPT AT 20 PSI FOR DURATION OF <br />CONSTRUCTION AND SHALL BE CHECKED FREQUENTLY. <br />4.SECONDARY TESTING: <br />(1) <br />5.VENTS, VAPOR, AND TANK RISER TESTING: <br />(1)UPON COMPLETION OF VAPOR RECOVERY PIPING, TEST SYSTEM AS FOLLOWS: <br />(a) <br />6.DUE TO WEATHER CONDITIONS, PRESSURES MAY RISE OR FALL OVER A <br />PERIOD OF TIME. PRESSURES SHALL BE MONITORED AT REGULAR INTERVALS <br />7.VENT AND VAPOR RECOVERY PIPING WITH PHASE II RECOVERY. <br />(1) <br />8.UPON COMPLETION OF THE FUELING SYSTEM, THE FOLLOWING ITEMS ARE REQUIRED: <br />(1)ST-27 TEST. <br />(2)ST-30 TEST. <br />(3)A over L TEST (IF REQUIRED). <br />(4)PLACED IN SERVICE REPORT. <br />(5) <br />(6)ALL METERS SEALED. <br />(7)TANK AND LINE TEST (3rd PARTY). <br />(8)FUEL SYSTEM CHECK TEST. <br />(9)AS BUILT DRAWINGS. <br />(10)MONITORING SYSTEM FINAL WITH APPROPRIATE AGENCY APPROVALS. <br />* <br />* <br />TO PREVENT FALSE READINGS. <br />ALL BLACK IRON PIPING TO BE PAINTED GREY.11. <br />INSTALL MONITORING SYSTEM WITH LIQUID SENSORS IN EACH TANK ANNULAR SPACE. INSTALL MONITOR <br />CONTROL PANEL IN NEW BUILDING AS DIRECTED BY OWNER. INSTALL LIQUID LEVEL PROBES IN TANKS. <br />SEE SITE ELECTRICAL PLAN FOR TANK CONDUIT CONFIGURATION. WHEN A LEAK IS DETECTED, AN <br />AUDIO/ VISUAL ALARM WILL GO ON. LEAK DETECTION @ SUMP WILL CAUSE SUMP SHUT DOWN LEAK <br />DETECTION @ DISPENSER SUMP WILL CAUSE DISPENSER SHUT DOWN. AUDIO/ VISUAL ALARM WILL GO <br />OFF IF ANNULAR SPACE MONITOR OR SUMP. MONITORING SYSTEM SHALL BE INSTALLED TO PERMIT <br />CONDITIONS. MONITORING SYSTEM TO BE INSTALLED TO THE SAME STANDARD FOR COMMUNICATIONS <br />AS REQUIRED BY OWNER. <br />INSTALL NEW CONCRETE TANK MAT AND OTHER CONCRETE AS INDICATED ON SITE PLAN. DRIVE SLAB <br />SHALL BE PER BUOYANCY CALCS. <br />INSTALL DISPENSERS AND CONSOLES AS INDICATED ON SITE PLAN AND DESCRIBED IN THE EQUIPMENT <br />LIST. <br />THE ABOVE MENTIONED LIST IS FOR REFERENCE ONLY. CITY, COUNTY, OR OTHER <br />GOVERNING AGENCIES, MAY HAVE OTHER REQUIREMENTS THAT MUST BE ADHERED TO. IT <br />IS THE CONTRACTORS RESPONSIBILITY TO CONFIRM AND MEET ALL REQUIREMENTS. <br />CONTRACTOR IS RESPONSIBLE FOR VENT AND VAPOR RECOVERY PIPING SYSTEM <br />PASSING ANY LOCALLY IMPOSED TEST REQUIREMENTS. <br />METER CALIBRATION, CONFIRMED AND ADJUSTED. (RESULTS MUST BE SENT TO WEIGHTS <br />& MEASURES WITHIN 24 HOURS OF COMPLETION) <br />UPON COMPLETION OF PRIMARY PIPING AND BEFORE GLUING. SECONDARY HAS <br />TO BE INSTALLED PRIOR TO GLUING OF PRIMARY. PRESSURE TESTING NOT TO <br />EXCEED THE MAXIMUM WORKING PRESSURE OF FUEL PIPING COMPONENTS. <br />IMPACT VALVES ARE RATED AT 50PSI TESTING TO BE ACCORDING TO PIPE <br />MANUFACTURER'S INSTRUCTIONS. <br />CONTRACTOR SHALL PROVIDE OWNER 48 HOUR NOTICE FOR TESTING <br />AND COMPLY WITH PERMIT CONDITIONS FOR LOCAL INSPECTORS.. <br />UPON COMPLETION OF SECONDARY PIPING AND BEFORE PLACEMENT OF ANY <br />BACKFILL, TEST SECONDARY PIPING AS REQUIRED BY PIPE MANUFACTURER. <br />THERE MUST BE TWO (2) GAUGES (0-100 PSI) PER PRODUCT BEING <br />TESTED. <br />MAKE SURE PERSONNEL ARE KEPT AWAY FROM PIPING SYSTEM DURING ANY <br />TIME INITIAL PRESSURIZATION IS BEING APPLIED. <br />APPLY PRESSURE IN 15-20 PSI INTERVALS UNTIL REACHING A MAXIMUM OF 60 <br />PSI. <br />MARK CRITICAL PRESURES ON GAUGES WITH ELECTRICAL TAPE AT THE <br />BEGINNING OF EACH TEST. <br />AFTER PROVING SYSTEM TIGHTNESS, APPLY 50 PSI PRESSURE, HOLD FOR ONE <br />MINUTE, THEN RELEASE PRESSURE. REPEAT PRESSURIZATION CYCLE A MINIMUM <br />OF (5) TIMES. <br />UPON COMPLETION OF THE ABOVE TESTS, KEEP PRESSURE AT 50 PSI FOR A <br />MINIMUM OF (3) HOURS. OBSERVE PRESSURE GAUGES FOR ANY LOSS. <br />THIS SITE IS PREVIOUSLY UNDEVELOPED AND HAS NO FUEL CONTAMINATION. <br />CONTRACTOR EMPLOYEES SHALL HAVE COMPLETED "APPROPRIATE <br />MANUFACTURERS PIPES TRAINING" (CERTIFICATE REQUIRED). CONTRACTOR SHALL <br />COMPLETE THE "PIPING SYSTEMS INSTALLATION CHECKLIST FOR UNDERGROUND <br />PETROLEUM PIPES" AND SHALL FURNISH THE OWNER WITH COPIES OF ALL <br />APPROPRIATE CERTIFICATES. <br />CONTRACTOR SHALL HAVE BEEN TRAINED BY "TANK MANUFACTURER FOR TANK <br />INSTALLATION" CONTRACTOR SHALL COMPLETE THE "TANK INSTALLATION CHECKLIST" <br />(SUPPLIED TO CONTRACTOR BY MANUFACTURER DURING TANK DELIVERY) AND SHALL <br />FURNISH A COPY OF THIS DOCUMENT TO THE OWNER. <br />CONTRACTOR SHALL DEVELOP A SPECIFIC SITE SAFETY PLAN PRIOR TO THE START OF <br />WORK. CONTRACTOR SHALL CONDUCT WEEKLY JOB SITE SAFETY MEETINGS WITH IT'S <br />EMPLOYEES. <br />CONTRACTOR SHALL SUBMIT PROOF OF ALL REQUIRED INSURANCE TO THE <br />OWNER AND SHALL NAME "ALLIED FUELS " AS "ALSO INSURED." <br />COMPREHENSIVE GENERAL LIABILITY, INCLUDING CONTRACTOR'S PROTECTIVE <br />LIABILITY, COMPLETED OPERATIONS LIABILITY, AND CONTRACTUAL LIABILITY, <br />WITH A COMBINED SINGLE LIMIT OF NOT LESS THAN $1,000,000 PER <br />OCCURRENCE FOR BODILY INJURY AND PROPERTY DAMAGE. <br />EMPLOYEES LIABILITY WITH A MINIMUM LIMIT OF LIABILITY OF $1,000,000 FOR <br />EACH OCCURRENCE. <br />AUTOMOBILE LIABILITY COVERING USE OF ALL OWNED HIRED VEHICLES WITH <br />A COMBINED SINGLE LIMIT OF SINGLE UNIT OF LIABILITY OF NOT LESS THAN <br />$1,000,000 PER OCCURRENCE FOR BODILY INJURY AND PROPERTY DAMAGE. <br />GENERAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, AND <br />SERVICES NECESSARY FOR OR REASONABLY INCIDENTAL TO THE SATISFACTORY <br />COMPLETION OF ALL WORK SHOWN ON, CALLED FOR, OR REQUIRED BY THE <br />DRAWINGS. <br />ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT 2016 <br />CALIFORNIA FIRE, BUILDING, ELECTRICAL AND MECHANICAL CODES, CCR TITLE <br />23,DIVISION 3, CHAPTER 16, ARTICLE 3; AND CALIFORNIA AIR RESOURCES BOARD <br />REQUIREMENTS. <br />ALL EXCAVATIONS SHALL BE PERFORMED IN COMPLIANCE WITH OSHA AND STATE <br />REGULATIONS. THE CONTRACTOR IS REFERRED TO THE OSHA BOOKLET, "EXCAVATING <br />AND TRENCHING OPERATIONS, FOR SAFE WORK PRACTICES GUIDE" FOR PERFORMING <br />EXCAVATION WORK. <br />UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL PROVIDE THE <br />OWNER WITH "AS BUILT" DRAWINGS OF ALL ITEMS INSTALLED BY THE CONTRACTOR. <br />"AS BUILTS" SHALL BE COMPLETED ON-SITE. <br />CONTRACTOR SHALL PROVIDE A WORK SCHEDULE TO THE OWNER BEFORE <br />COMMENCING ANY CONSTRUCTION WORK. <br />CONTRACTOR SHALL COORDINATE ALL INSPECTIONS AND APPROVALS AND <br />SHALL OBTAIN, AT THE COMPLETION OF THE PROJECT, ALL CERTIFICATES <br />REQUIRED TO OPERATE THE FACILITY. <br />FENCE OFF FUEL SYSTEM WORK AREA WITH 6' HIGH CHAIN LINK FENCE. AT THE <br />END OF EACH WORK DAY SECURE FENCING PANELS TOGETHER. <br />THE OWNER SHALL PROVIDE FOR TRANSPORTATION AND DISPOSAL OF EXCAVATED SOIL <br />AFTER COMPLETION OF ANY NECESSARY REMEDIATION, INCLUDING AERATION. <br />INSTALL NEW PETROLEUM PRODUCT, VENT & VAPOR LINES PER SITE PLAN, STANDARD <br />TANK DRAWINGS, AND PER PIPING GENERAL NOTES ON SHEET FS-1. <br />ALL PIPING OTHER THAN FIBERGLASS SHALL BE <br />BLACK IRON (GALVANIZED PIPE IS NOT <br />ALLOWED). ALL BELOW GRADE PIPING SHALL BE <br />FRP, NO EXCEPTIONS. <br />NEW HIRT VENT SYSTEM, INSTALL PER MANUFACTURER'S <br />INSTRUCTIONS. <br />DO NOT SUBJECT THE EVR APPROVED EQUIPMENT TO PRESSURES HIGHER THAN THE <br />MANUFACTURERS RECOMMENDATIONS. <br />(b)TANKS TO BE TESTED PER MANUFACTURER'S WRITTEN INSTRUCTIONS AS TO NOT VOID THE <br />WARRANTY. <br />FS1.0 <br />A.ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE <br />MANUFACTURER'S INSTALLATION SPECIFICATIONS AND INSTRUCTIONS SEE <br />NOTES BELOW. <br />B.FIBERGLASS PIPING SHALL BE LIMITED TO THE FOLLOWING: <br />SMITH FIBERGLASS RED THREAD IIA FOR PRODUCT, VENT AND VAPOR LINES, <br />USING ONLY DS8000 SERIES ADHESIVES TO JOIN PRIMARY PRODUCT AND <br />SECONDARY CONTAINMENT PIPE AND ALCOHOLS AND FITTINGS FOR <br />ALCOHOL-GASOLINE MIXTURES. WHEN JOINING SECONDARY <br />CONTAINMENT FITTINGS, A SPECIAL FILLER FROM SMITH FIBERGLASS <br />PRODUCTS MUST BE ADDED TO THE DS8000 SERIES ADHESIVES. <br />1.)UNDERGROUND PIPING: SMITH FIBERGLASS SYSTEMS: <br />MIN. AMOUNT OF <br />PEA GRAVEL <br />ABOVE THE TOP <br />OF THE PIPE <br />MINIMUM <br />BURIAL <br />DEPTH <br />SURFACE <br />CONDITION <br />PIPE <br />SIZE <br />PIPE <br />MANUFACTURER <br />SMITH FIBERGLASS <br />RED THREAD IIA <br />12" <br />8" <br />5" <br />14" <br />9" <br />7" <br />14" <br />10" <br />7" <br />17" <br />12" <br />9" <br />20" <br />13" <br />11" <br />20" <br />14" <br />11" <br />2" <br />3" <br />4" <br />E. <br />16.PIPING MANUFACTURER AND INSTALLATION REQUIREMENTS <br />DRAWING INDEX <br />MANTECA <br />1014 S. AIRPORT ROAD <br />MANTECA , CA 95336 <br />fuel system <br />C.ABOVE GROUND PIPING FOR FUELS: <br />1.) BLACK IRON AND BLACK IRON FITTINGS. SINGLE WALL. <br />GALVANIZED PIPE IS NOT PERMITTED. <br />D. <br />MANTECA, CALIFORNIA <br />FUELING SYSTEM <br />FS1.0 FUEL SYSTEM COVER SHEET & GENERAL NOTES <br />FS1.1 TANKS AND LINES SITE PLAN <br />FS1.2 ENLARGED FUEL SYSTEM SITE PLAN <br />FS2.0 EQUIPMENT LISTS <br />FS3.0 TANK SECTIONS <br />FS3.1 TANK SECTIONS <br />FS4.0 DETAILS <br />FS5.0 DIESEL TANK SUMPS, VENT DETAILS <br />FS6.0 TANK AND LINE WET HOLE DETAILS <br />FS7.0 MONITORING SYSTEM <br />FS4.1 87 AND 91 TANK SUMP DETAILS <br />CALIFORNIA FIRE CODE NOTES <br />PRIOR TO FINAL, DOCUMENTATION FROM THE SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH <br />DEPARTMENT HAZARDOUS MATERIAL DIVISION INDICATING THAT THE UNDERGROUND <br />FLAMMABLE/COMBUSTIBLE LIQUIDS STORAGE TANKS HAVE BEEN APPROVED SHALL BE PROVIDED <br />NOTE: <br />THE TANK AND THE TANK SUMPS HAVE CALCIUM CHLORIDE IN <br />THE INTERSTITIAL SPACE. <br />THE DISPENSER SUMPS AND VENT SUMPS HAVE PROPYLENE <br />GLYCOL IN THE INTERSTITIAL SPACE <br />CONTRACTOR TO LABEL FILL PORTS WITH TYPE OF FILL. <br />CODES <br />THESE DRAWINGS HAVE BEEN PREPARED USING: THE 2022 CALIFORNIA BUILDING CODE, <br />CALIFORNIA FIRE CODE, CALIFORNIA ELECTRICAL CODE, CALIFORNIA MECHANICAL CODE, <br />CALIFORNIA PLUMBING CODE, CALIFORNIA ENERGY CODE, AND CALIFORNIA GREEN BUILDING <br />STANDARDS CODE(S) AND ORDINANCES. ALL WORK SHALL COMPLY WITH CURRENT <br />ACCESSIBILITY REQUIREMENTS. <br />NOTE: PERSONS INSTALLING PIPING MUST BE CERTIFIED AS HAVING <br />BEEN TRAINED BY THE PIPING MANUFACTURER. <br />PIPING TO BE INSTALLED WITH THE MINIMUM DEPTHS LISTED BELOW. ALL <br />CROSSOVERS OF PIPING SHALL HAVE 6" MINIMUM BETWEEN PIPES. <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, <br />CONCRETE (4" <br />MINIMUM) <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, <br />CONCRETE (4" <br />MINIMUM) <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, <br />CONCRETE (4" <br />MINIMUM) <br />SCALE: N.T.S. <br />SITE <br />1 <br />3 <br />3 <br />3 <br />FS7.1 MONITORING SYSTEM <br />5 <br />FUEL SYSTEM COVER <br />SHEET & GENERAL <br />NOTES <br />6