My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1014
>
2300 - Underground Storage Tank Program
>
PR2500513
>
INSTALL_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2025 8:24:03 AM
Creation date
8/28/2025 4:40:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2025
RECORD_ID
PR2500513
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0004333
FACILITY_NAME
Rotten Robbie #69
STREET_NUMBER
1014
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
Manteca
Zip
95337
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1014 S AIRPORT WAY Manteca 95337
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
448
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SASASASASASASASASASASASASASASASASASASASASASTSTSTSTSTSTSSSS SS SS SS SS <br />W WWW <br />WW W W W W W W W W <br />W WWEEEEEEEWWWWWSS <br />NO PARKINGNO PARKINGEV CHARGING <br />ONLY <br />EV CHARGING <br />ONLY <br />EV CHARGING <br />ONLY CLEAN AIRCLEAN AIREV CHARGING <br />ONLY NO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANE <br />NO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANE20K U20K D12K SFS1.1 <br />TANKS AND LINES <br />SITE PLAN <br />20 TANKS AND LINES SITE PLAN <br />1" = 20'-0"SCALE: <br />PIPING GENERAL NOTES <br />FUEL KEY NOTES <br />FUEL LINE LEGEND <br />5 <br />2 <br />3 <br />1 <br />GENERAL TANK & LINE NOTES <br />THESE PLANS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO BE AN <br />EXACT REPRESENTATION OF THE FINAL PRODUCT. PLANS ARE TO BE FOLLOWED <br />AS APPROVED BY THE EHD. IF MODIFICATION ARE REQUIRED, THE GENERAL <br />CONTRACTOR SHALL NOTIFY ARCHITECT/EDH BEFORE PROCEEDING. <br />INSTALL NEW DOUBLE WALL PIPING FROM 3-UST TANKS - 1-20,000 GAL 87 <br />UNLEADED; 1-20,000 GAL DIESEL; 1-12,000 91 UNLEADED <br />ALL AUTO FUEL PRODUCT LINES (2") AND SECONDARY CONTAINMENT (3" PIPING <br />SHALL BE 100% METHANOL COMPATIBLE), U.N.O. ON PLAN. SMITH RED THREAD IIA <br />IS SPECIFIED. SEE PIPING NOTES FOR ADHESIVES. ALL VENTS UP TO GRADE <br />SHALL BE 100% METHANOL COMPATIBLE. ALL NEW PIPING TO BE INSTALLED PER <br />MANUFACTURER'S SPECIFICATIONS. SLOPE PIPING 1/4" PER FOOT BACK TO TANKS. <br />INSTALL 4"/3" DOUBLE WALLED VAPOR RECOVERY LINES FROM DISPENSERS. <br />SLOPE 1/4" PER FOOT 87 GAS TANK. <br />4 <br />6 CFC 2305.3 REQUIRES SPILLS TO BE PREVENTED FROM FLOWING INTO BUILDINGS. <br />THE FINISH FLOOR OF THE BUILDING IS 1' MIN HIGHER THAN ALL FUELING OPERATION <br />LOCATIONS. <br />INSTALL 3"/2"" DOUBLE WALLED VENT LINES FROM TANKS TO VENT STACK. SLOPE <br />1/4" PER FOOT BACK TO TANK. <br />DIESEL <br />VAPOR RECOVERY <br />VENT LINE <br />87 UNLEADED <br />91 UNLEADED <br />SEE SHEET FS2.0 FOR EQUIPMENT LIST <br />NOTE: <br />1.ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE <br />MANUFACTURER'S INSTALLATION SPECIFICATIONS AND INSTRUCTIONS. <br />2.FIBERGLASS PIPING SHALL BE LIMITED TO THE FOLLOWING: <br />SMITH FIBERGLASS RED THREAD IIA FOR PRODUCT, VENT AND VAPOR LINES, <br />USING ONLY DS8000 SERIES ADHESIVES TO JOIN PRIMARY PRODUCT AND <br />SECONDARY CONTAINMENT PIPE AND ALCOHOLS AND FITTINGS FOR <br />ALCOHOL-GASOLINE MIXTURES. WHEN JOINING SECONDARY CONTAINMENT <br />FITTINGS, A SPECIAL FILLER FROM SMITH FIBERGLASS PRODUCTS MUST BE <br />ADDED TO THE DS8000 SERIES ADHESIVES. <br />A)SMITH FIBERGLASS SYSTEMS: <br />3.ALL PIPING SYSTEMS SHALL BE TESTED AS FOLLOWS: SEE <br />SCOPE OF WORK ITEM 8 SHEET F1.0. <br />MIN. AMOUNT OF <br />PEA GRAVEL <br />ABOVE THE TOP <br />OF THE PIPE <br />MINIMUM <br />BURIAL <br />DEPTH <br />SURFACE <br />CONDITION <br />PIPE <br />SIZE <br />PIPE <br />MANUFACTURER <br />SMITH FIBERGLASS <br />RED THREAD IIA <br />12" <br />8" <br />5" <br />14" <br />9" <br />7" <br />14" <br />10" <br />7" <br />17" <br />12" <br />9" <br />20" <br />13" <br />11" <br />20" <br />14" <br />11" <br />2" <br />3" <br />4" <br />4.PIPING TO BE INSTALLED WITH THE MINIMUM DEPTHS LISTED <br />BELOW. ALL CROSSOVERS OF PIPING SHALL HAVE 6" MINIMUM <br />BETWEEN PIPES. <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, CONCRETE <br />(4" MINIMUM) <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, CONCRETE <br />(4" MINIMUM) <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, CONCRETE <br />(4" MINIMUM) <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />MOUNT EMERGENCY FUEL SHUT-OFF SWITCH, +48" ON CANOPY <br />COLUMN. PROVIDE SIGN PER DETAIL 9/FS4.0 <br />TLS 450 <br />MSB <br />FUEL ELECTRICAL PANELS <br />VENT LINES <br />FUEL LINES <br />CASHIER FUEL CONTROLS <br />LOCATION OF FIRE EXTINGUISHER IN SURFACE MOUNTED CABINET. MUST <br />BE WITHIN 75' OF ALL DISPENSERS AND FILLS. FIRE EXTINGUISHER SHALL <br />BE 2-A:20-B:C RATED. CFC 2305.5 <br />FUEL DISPENSER WARNING SIGN, TO BE VISIBLE WITHIN 10' OF EACH <br />DISPENSER. THESE STICKERS ARE LOCATED ON EACH DISPENSER. SEE <br />DETAIL 11,17/FS4.0 <br />20K UST FOR DIESEL TANK <br />20K UST FOR 87 REGULAR UNLEADED GAS TANK <br />12K UST FOR 91 PREMIUM UNLEADED GAS TANK <br />TANK OVER FILL ALARM AND RESET BUTTON SEE DETAIL 12 / FS3.1 <br />VENT SUMP AND RACK WITH CANISTER SEE DETAIL 12 / FS5.0 <br />AUTO DRIVE SLAB, SEE DETAIL 2/FS4.0 <br />EMERGENCY SHUT-OFF SWITCH SEE DETAIL 12 / FS3.1 <br />8" CONCRETE TANK SLAB, SEE DETAIL 13/FS4.0 <br />16 <br />SHEET NUMBER: <br />SHEET CONTENTS: <br />PROJECT NUMBER:PROJECT DATE: <br />CONSULTANTS: <br />REVISIONS: <br />18-046 12-24-2020 <br />DEVELOPER: <br />CONTRACTOR: <br />PROJECT: <br />PROFESSIONAL SEALS: <br />1014 S. Airport Road <br />Manteca, California <br /> 95336 <br />1 <br />2 <br />Robinson Oil Corporation <br />955 Martin Ave. <br />Santa Clara, CA 95050 <br />Sacramento, CA 95827 <br />PH:(916) 455-6500 FAX:(916) 455-8100 <br />3090 Fite Circle, #104 <br />K12 Architects, Inc <br />CONVENIENCE STORE & <br />FUELING CANOPY <br />MANTECA <br />3 <br />4 <br />PLAN CHECK JAN. 12, 2023 <br />OWNER CHANGE MARCH 17, 2023 <br />PLAN CHECK AUGUST 17, 2023 <br />PLAN CHECK MARCH 29, 2024 <br />PLAN CHECK hzmt MAY 10, 2024 <br />5 PLAN CHECK hzmt MAY 31, 2024 <br />6 PLAN CHECK hzmt AUGUST 7, 2024 <br /> November 06, 2024 <br />8 PLAN CHECK hzmt OCT. 26, 2024 <br />7 PLAN CHECK hzmt SEPT. 26, 2024 <br />1 <br />24 <br />3 <br />5 <br />6 <br />7 <br />8 <br />9 <br />1011 <br />12 <br />13 14 <br />15R100'-0"3 <br />3 <br />3 <br />3 <br />3 <br />17 <br />4 <br />17 <br />0 20'40'60' <br />AUTO FUEL <br />ISLAND <br />5R100'-0"14'-0"6 <br />6 <br />6 <br />NOTE: <br />SEE DETAIL 16 / FS3.1 FOR TYPICAL PIPING CROSS OVER 6 <br />6 <br />7
The URL can be used to link to this page
Your browser does not support the video tag.