My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1014
>
2300 - Underground Storage Tank Program
>
PR2500513
>
INSTALL_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2025 8:24:03 AM
Creation date
8/28/2025 4:40:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2025
RECORD_ID
PR2500513
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0004333
FACILITY_NAME
Rotten Robbie #69
STREET_NUMBER
1014
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
Manteca
Zip
95337
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1014 S AIRPORT WAY Manteca 95337
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
448
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20K U20K D12K S16 <br />NO PARKINGCLEAN AIRCLEAN AIRNO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANE <br />2 <br />4 <br />3 <br />5 <br />6 <br />7 <br />1 <br />9 <br />1011 <br />12 <br />1314 <br />15 <br />8 <br />AUTO FUEL <br />ISLAND <br />FS1.220TANKS AND LINES SITE PLAN <br />1" = 10'-0"SCALE: <br />PIPING GENERAL NOTES <br />FUEL KEY NOTES <br />FUEL LINE LEGEND <br />DIESEL <br />VAPOR RECOVERY <br />VENT LINE <br />87 UNLEADED <br />91 UNLEADED <br />SEE SHEET FS2.0 FOR EQUIPMENT LIST <br />NOTE: <br />1.ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE <br />MANUFACTURER'S INSTALLATION SPECIFICATIONS AND INSTRUCTIONS. <br />2.FIBERGLASS PIPING SHALL BE LIMITED TO THE FOLLOWING: <br />SMITH FIBERGLASS RED THREAD IIA FOR PRODUCT, VENT AND VAPOR LINES, <br />USING ONLY DS8000 SERIES ADHESIVES TO JOIN PRIMARY PRODUCT AND <br />SECONDARY CONTAINMENT PIPE AND ALCOHOLS AND FITTINGS FOR <br />ALCOHOL-GASOLINE MIXTURES. WHEN JOINING SECONDARY CONTAINMENT <br />FITTINGS, A SPECIAL FILLER FROM SMITH FIBERGLASS PRODUCTS MUST BE <br />ADDED TO THE DS8000 SERIES ADHESIVES. <br />A)SMITH FIBERGLASS SYSTEMS: <br />3.ALL PIPING SYSTEMS SHALL BE TESTED AS FOLLOWS: SEE <br />SCOPE OF WORK ITEM 8 SHEET F1.0. <br />MIN. AMOUNT OF <br />PEA GRAVEL <br />ABOVE THE TOP <br />OF THE PIPE <br />MINIMUM <br />BURIAL <br />DEPTH <br />SURFACE <br />CONDITION <br />PIPE <br />SIZE <br />PIPE <br />MANUFACTURER <br />SMITH FIBERGLASS <br />RED THREAD IIA <br />12" <br />8" <br />5" <br />14" <br />9" <br />7" <br />14" <br />10" <br />7" <br />17" <br />12" <br />9" <br />20" <br />13" <br />11" <br />20" <br />14" <br />11" <br />2" <br />3" <br />4" <br />4.PIPING TO BE INSTALLED WITH THE MINIMUM DEPTHS LISTED <br />BELOW. ALL CROSSOVERS OF PIPING SHALL HAVE 6" MINIMUM <br />BETWEEN PIPES. <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, CONCRETE <br />(4" MINIMUM) <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, CONCRETE <br />(4" MINIMUM) <br />UNPAVED <br />PAVED, ASPHALT <br />(4" MINIMUM) <br />PAVED, CONCRETE <br />(4" MINIMUM) <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />MOUNT EMERGENCY FUEL SHUT-OFF SWITCH, +48" ON CANOPY <br />COLUMN. PROVIDE SIGN PER DETAIL 9/FS4.0 <br />TLS 450 <br />MSB <br />FUEL ELECTRICAL PANELS <br />VENT LINES <br />FUEL LINES <br />CASHIER FUEL CONTROLS <br />LOCATION OF FIRE EXTINGUISHER IN SURFACE MOUNTED CABINET. MUST <br />BE WITHIN 75' OF ALL DISPENSERS AND FILLS. FIRE EXTINGUISHER SHALL <br />BE 2-A:20-B:C RATED. CFC 2305.5 <br />FUEL DISPENSER WARNING SIGN, TO BE VISIBLE WITHIN 10' OF EACH <br />DISPENSER. THESE STICKERS ARE LOCATED ON EACH DISPENSER. SEE <br />DETAIL 11 & 17/FS4.0 <br />20K UST FOR DIESEL TANK <br />20K UST FOR 87 REGULAR UNLEADED GAS TANK <br />12K UST FOR 91 PREMIUM UNLEADED GAS TANK <br />TANK OVER FILL ALARM AND RESET BUTTON SEE DETAIL 12 / FS3.1 <br />VENT SUMP AND RACK WITH CANISTER, SEE DETAIL 12 / FS5.0 <br />AUTO DRIVE SLAB, SEE DETAIL 2/FS4.0 <br />EMERGENCY SHUT-OFF SWITCH AND SIGN, SEE DETAIL 12 / FS3.1 <br />SHEET NUMBER: <br />SHEET CONTENTS: <br />PROJECT NUMBER:PROJECT DATE: <br />CONSULTANTS: <br />REVISIONS: <br />18-046 12-24-2020 <br />DEVELOPER: <br />CONTRACTOR: <br />PROJECT: <br />PROFESSIONAL SEALS: <br />1014 S. Airport Road <br />Manteca, California <br /> 95336 <br />1 <br />2 <br />Robinson Oil Corporation <br />955 Martin Ave. <br />Santa Clara, CA 95050 <br />Sacramento, CA 95827 <br />PH:(916) 455-6500 FAX:(916) 455-8100 <br />3090 Fite Circle, #104 <br />K12 Architects, Inc <br />CONVENIENCE STORE & <br />FUELING CANOPY <br />MANTECA <br />3 <br />4 <br />PLAN CHECK JAN. 12, 2023 <br />OWNER CHANGE MARCH 17, 2023 <br />PLAN CHECK AUGUST 17, 2023 <br />PLAN CHECK MARCH 29, 2024 <br />PLAN CHECK hzmt MAY 10, 2024 <br />5 PLAN CHECK hzmt MAY 31, 2024 <br />6 PLAN CHECK hzmt AUGUST 7, 2024 <br /> November 06, 2024 <br />8 PLAN CHECK hzmt OCT. 26, 2024 <br />7 PLAN CHECK hzmt SEPT. 26, 2024 <br />ENLARGED FUEL <br />SYSTEM SITE PLAN100' R100' R3 <br />3 <br />0 10'20'30' <br />5 <br />6 <br />6 <br />6 <br />NOTE: <br />SEE DETAIL 16 / FS3.1 FOR TYPICAL PIPING CROSS OVER 6 <br />6 <br />7
The URL can be used to link to this page
Your browser does not support the video tag.