My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2800 - Aboveground Petroleum Storage Program
>
PR0527630
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 3:01:48 PM
Creation date
9/10/2025 2:56:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0527630
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint Stockton Switch
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
AVE
City
Stockton
Zip
95204
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
3807 Coronado AVE Stockton 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aboveground Petroleum Storage Act Program Inspection Report <br />Date: <br />August 19, 2025 <br />Facility Address: <br />3807 Coronado AVE, StocktonSprint United Managemnt Co. <br />Facility Name: <br />Environmental Health Department <br />57 Code of Fed Regulations 112.7(e), 112.8(c)(6) 4010021 - Written Inspection/testing procedures kept, inspection/testing <br />records signed, kept for 3 years <br />OBSERVATION: The facility failed to keep written procedures and records of inspections and tests, including integrity <br />tests, for at least three years. Copies of inspection and testing records for November 2023 through August 2025 were not <br />found on site. The inspection records observed on site documented monthly inspections conducted by T-Mobile <br />personnel. The facility could not provide written records of monthly inspections conducted using the checklist included in <br />the SPCC Plan and Data Center Operations Manager Juan Aguilera stated he has not conducted monthly inspection. <br />REGULATION GUIDANCE: 112.7(e), Conduct inspections and tests required by this part in accordance with written <br />procedures that you or the certifying engineer develop for the facility. You must keep these written procedures and a <br />record of the inspections and tests, signed by the appropriate supervisor or inspector, with the SPCC Plan for a period of <br />three years. Records of inspections and tests kept under usual and customary business practices will suffice for <br />purposes of this paragraph. 112.8(c)(6) Test or inspect each aboveground container for integrity on a regular schedule <br />and whenever you make material repairs. <br />CORRECTIVE ACTION: Inspections and tests must be conducted in accordance with the written procedures developed <br />in the Spill Prevention, Control, and Countermeasure (SPCC) Plan. Records of these inspections and tests must be <br />signed by the appropriate supervisor or inspector and kept on-site with the SPCC Plan for three years. Immediately <br />locate a copy of all inspection and testing records for the last three years, maintain them on-site, and submit copies to the <br />EHD. <br />This is a Repeat (Class 2) Violation. <br />61 Code of Fed Regulations 112.8(c)(8)(v) 4030022 - Liquid level sensing devices regularly tested to ensure proper <br />operation <br />OBSERVATION: Liquid level sensing devices for the required 8,000-gallon and 5,000-gallon ASTs have not been tested. <br />The monthly Visual Inspection Log included in Appendix B addresses leak detection systems including fuel gauges and <br />leak detection. No records of monthly inspections past October 2023 were available during the inspection and Data <br />Center Operations Manager Juan Aguilera stated monthly inspections have not been conducted. <br />REGULATION GUIDANCE: (c)(8)(v) You must regularly test liquid level sensing devices to ensure proper operation. <br />CORRECTIVE ACTION: Liquid level sensing devices must be installed in accordance with CFR 112.8 and shall be <br />regularly tested to ensure proper operation. Immediately conduct all necessary testing of the 8,000-gallon and 5,000- <br />gallon tanks liquid level sensing devices to ensure proper operation, Submit test results to the EHD. <br />This is a (Class 2) Violation. <br />63 Code of Fed Regulations 112.8(c)(10) 4030021 - Visible discharges promptly corrected and any accumulation of oil in <br />diked areas promptly removed. <br />OBSERVATION: The facility failed to promptly correct visible discharges of oil from including but not limited to seams, <br />gaskets, piping, pumps, valves, rivets, and bolts. <br />-Oily staining was observed on the ground under the oil drain of generator 4 <br />-Oily staining was observed under generator 3 and in the southeast corner of the room adjacent to the generator. <br />-Oily staining was observed inside the generator 1 containment room above the 8,000-gallon capacity diesel tank. Data <br />Center Operations Manager Juan Aguilera stated he has already put in a work order for an active leak from the system. <br />REGULATION GUIDANCE: (c)(10) Promptly correct visible discharges which result in a loss of oil from the container, <br />including but not limited to seams, gaskets, piping, pumps, valves, rivets, and bolts. You must promptly remove any <br />accumulations of oil in diked areas. <br />CORRECTIVE ACTION: Immediately fix leaks, remove stains, and manage all wastes according to the California Code <br />of Regulations Title 22 hazardous waste regulations, submit proof of correction to the EHD. <br />This is a (Class 2) Violation. <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 7 of 9EHD - CUPA Inspection Report IS02 8/25/2025FA0003819 PR0527630 4539855
The URL can be used to link to this page
Your browser does not support the video tag.