D.17. SHIPPING/TRANSPORTATION HAZMAT/DANGEROUS GOODS ❑Applicable — Not Applicable, Not Anticipated
<br /> MODE(S)OF TRANSPORT: ❑Road ❑Rail ❑Air ❑Sea ❑Inland Waterway ❑International
<br /> IMPORTANT:Ensure that each individual who will be involved in shipping/transportation of hazardous material is current with required training(awareness,function-
<br /> specific,safety,security)in accordance with applicable regulatory authority(DOT,FAA,IATA,TDG),and ensure adherence to applicable regulations.
<br /> HSE Program Documents:HSE SOP-235a:Hazardous Materials Shipping(US-only)
<br /> Site-Specific Notes&Clarifications:
<br /> PART E-AIR MONITORING, WORKER EXPOSURE MONITORING
<br /> E.1. AIR MONITORING Applicable ® Not Applicable, Not Anticipated
<br /> Site-Specific Notes,Clarifications:
<br /> AIR-TESTING PARAMETERS-Select site-specific testing parameters;list associated equipment in Part C.2,Safety Equipment List.
<br /> ❑VOCs E ❑02(Oxygen)—oxygen meter
<br /> El Particulates-total dust meter
<br /> ❑PID(Photoionization detector): X eV ❑LEL(Lower Explosive Level)-LEL meter ❑%Methane—methane meter
<br /> ❑FID(Flame ionization detector) ❑112S(Hydrogen Sulfide)-H2S detector • ❑Calibration kit for each parameter
<br /> ❑Colorimetric indicator tubes-describe above El CO(Carbon monoxide)-CO detector El Other:
<br /> SUBSTANCE-SPECIFIC(PRE-SET)ACTION LEVELS-Sustained breathing zone action levels sustained general work-area levels for LEL).
<br /> 1.9.5-23% E Acceptable to continue work w_ith_out 02-focused respiratory protection.
<br /> Oz <19.5% rSTOP WORK,ventilate to raise 02 to>19.5%for re-entry. For persistent hazard,contact Corp.HSE Dept.
<br /> ❑ (Oxygen) --------------- -- ------------------- --- - -- -- - -- - - --------------------------------------------------------------------------------------------------------------------------------------
<br /> >23.0% STOP WORK,ventilate to lower 02 to<23%for re-entry. For persistent hazard,contact Corp.HSE Dept.
<br /> IMPORTANT: Confirm sufficient oxygen is present(min.8-12%)to ensure accurate LEL readings.
<br /> LEL(Lower <10%LEL r Acceptable to continue working in work area;continue to monitor LEL.
<br /> Explosive Limit) STOP WORK. Implement controls(reposition workers,ventilate,contain/eliminate source,etc.);resume
<br /> >10%LEL work ONLY when LEL readings are<10%,sustained.
<br /> <1 ppm Acceptable to continue work without H2S-focused respiratory protection.
<br /> .
<br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit
<br /> 1-10 ppm exposures to<1ppm,or use APR*with VOC/acid-gas cartridges(yellow);do not exceed MUC*for respirator
<br /> HzS
<br /> ❑ type;confirm acceptability of respirator usage with HSE Dept.
<br /> (Hydrogen Sulfide) } ------------ -- -- --- ------- ------ ----- ---------
<br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit
<br /> >10 ppm E exposures to<10ppm(with respirator),or<lppm(without respirator). For persistent levels>10 ppm,STOP
<br /> WORK,contact task lead,PM or HSE Dept.
<br /> CO <25 ppm Acceptable to continue work without CO-focused respiratoryprotection.
<br /> ❑ (Carbon >25 ppm r Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit
<br /> Monoxide) exposures to<25ppm. For persistent levels>25ppm,STOP WORK,contact PM and/or HSE Dept.
<br /> <69 I In this Air Quality Index(AQI)range,it's acceptable to continue work without respiratory protection.
<br /> ---------------------------------------
<br /> >69-<100 Voluntary use of N95 respirator is appropriate.
<br /> r Distribute N95 respirators to all personnel
<br /> WILDFIRE Provide work and/or rest areas in enclosed buildings.
<br /> F-1 SMOKE Relocate work indoors,or to an outdoor location with a lower AQI;
<br /> I >101-<500 Changing work schedules so outdoor work can occur when the AQI is lower;
<br /> (AQI for PM 2.5) Providing portable HEPA filters in enclosed areas;
<br /> Reduce the amount of work that involves physical exertion,and provide additional rest periods.
<br /> Consider rescheduling fieldwork to a date/time when the AQI is likely to be lower.
<br /> >500 r STOP WORK,or use APR*with approval of HSE Dept.
<br /> ❑ <OTHER> r----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
<br /> SITE-DERIVED ACTION LEVELS-Sustained breathing zone action levels;derived based on site contaminants;REVIEW WITH CORP.HSE DEPT.REQUIRED.
<br /> <X ppm Acceptable to continue work without VOC-focused respiratory protection.
<br /> >„ m Implement controls(reposition workers,ventilation,containment,eliminate source,etc.) to lower VOC
<br /> VOCS : pp exposures to less than specified action level,or use APR*with approval of Corp.HSE Dept.
<br /> (Volatile Organic Use APR*with VOC cartridges(yellow or black);do not exceed MUC**for respirator type;confirm
<br /> Compounds) X to X ppm
<br /> i procedures for respirator usage with HSE Dept:
<br /> >X ppm STOP WORK. Implement controls,for persistent levels greater than action contact PM and/or HSE Dept.
<br /> AIRBORNE -----------<X Mg/
<br /> m3 Acceptable pp --
<br /> table to continue work without articulate-focused respiratory protection.
<br /> ---------- ----------------- ----- ----------------------------------------------------- ------------------------------------ --------- - -----------------------------------------------
<br /> ❑
<br /> DUST > mg/m3 i Implement controls(water spray,reposition workers,ventilation,containment,etc.)to lower dust levels to
<br /> less than specified action level,or use APR*with approval of HSE Dept.
<br /> aGeosyntec° Project/Task Name: Well Maintenance THA ver.
<br /> consultants THA Date:4/17/25 Page 16
<br />
|