Laserfiche WebLink
.................................................................. ...................................................................................................................................................................................................... <br /> STORAGE/TRANSPORT OF ❑Transport chemicals only in sealed containers,secured to prevent shifting/breakage during travel. <br /> CHEMICALS/HAZMAT ❑Store chemicals only in sealed containers;overnight storage in squirt/spray bottles prohibited. <br /> ❑Non-Emergency(Routine) ElStore flammable/combustible liquids in chemical storage cabinets,or other appropriate storage arrangement. <br /> Chemical Storage Risk of personal ❑For liquids,provide secondary containment during storage. <br /> contact and/or incidental release ❑Segregate incompatible chemicals during storage. <br /> El HAZMAT Transport ElFor incidental release/spill;maintain spill kit suitable for low flammability/toxicity/quantity/volatility release. <br /> ❑DOT/TDG/IATA-Regulated transport:see D.17."Hazmat/Dangerous Goods Shipping/Transportation. <br /> ❑Risk of Emergency Spill/Release ❑For emergency spills:describe spill/release hazard and response plan/procedure above,and indicate <br /> ❑CFTAS(Chemical Facility Anti- emergency response contact in Part B,"Emergency Response and First Aid." <br /> Terrorism Standards)Applicability: ❑Locate emergency gear(eyewash,fire extinguisher,spill kit,safety signage)near storage area,as applicable. <br /> On-site overnight storage of non- ❑For CFTAS-applicable chemical storage,a safety and chemical management plan must be prepared and <br /> waste chemical product at quantity reviewed by a HSE Professional before bringing material to the site.(Does not apply to materials brought on to <br /> >25 gal(115L)or 2250 lbs.(115 kg) E the site for daily work purposes and transported away at the end of each day) <br /> ® COMPRESSED GAS CYLINDERS X Secure cylinders upright,caps on when not in use. <br /> X Flammable X Handle with care;use and store cylinders in a manner and location to prevent damage. <br /> ❑Non-flammable ®Propane cylinders not in use must be stored outdoors in a cage or similar secure ventilated enclosure. <br /> ❑Toxic ❑Ensure acetylene cylinders are NOT secured to steel arc welding bench. <br /> ❑Asphyxiant ❑Segregate oxygen and fuel gases by distance(20')or fire-rated barrier. <br /> ❑Oxygen ❑Control ignition sources. <br /> ❑"No smoking"signage at cylinder storage area for flammable gases. <br /> FLAMMABLE/COMBUSTIBLE ❑Use proper fuel safety can(metal fuel container with self-closing spout and flame arrestor preferred). <br /> LIQUIDS ❑Control/remove ignition sources near storage and use areas. <br /> ❑Grounding and bonding where appropriate. <br /> ❑Ensure a Type B or ABC fire extinguisher is readily available. <br /> ACIDS,CAUSTICS,OTHER ❑Use appropriate protection for eyes/face(goggles/face shield)and skin(gloves,sleeves,apron). <br /> CORROSIVES ❑Use eyewash,deluge shower,drench hose,hand washing(with water),as appropriate. <br /> ❑For severe eye hazards(due to high corrosivity,large quantity),15-min.eyewash required. <br /> TOXIC ❑For toxic substances,use/store in a manner to control exposure hazards(inhalation,ingestion,skin contact, <br /> skin absorption);use active ventilation and/or PPE as appropriate. <br /> ® EMISSIONS FROM FUEL X Position outdoor personnel upwind of exhaust source. <br /> COMBUSTION,HOT PROCESSES X Avoid"idling"of equipment when not in use. <br /> ❑Gasoline E ❑Use passive ventilation(air infiltration/air currents)to disperse atmospheric hazards in breathing zone. <br /> ❑Diesel E ❑Use dilution ventilation(blowers/fans)to provide fresh air to work area and dissipate atmospheric hazards. <br /> ❑Propane/Natural Gas ❑Use exhaust ventilation(hood/duct/exhaust stack/blower)to capture/divert exhaust from work area. <br /> ❑Welding/cutting/hot work ❑Use respiratory protection for high levels of smoke,exhaust particulates,soot. <br /> ®Vehicle/equipment exhaust ❑Conduct air monitoring as appropriate;see Part E,"Air Monitoring,Worker Exposure Monitoring." <br /> ❑Other <br /> OTHER HAZARDS r ❑Describe other hazardous substances and safety measures under"Site-Specific Notes&Clarifications,"above. <br /> HSE Program Documents: HSE STD-125:Personal Protective Equipment Program,HSE STD-130:Respiratory Protection Program HSE STD-145:Safety Training <br /> Program,HSE STD-150:Globally Harmonized System for Hazard Communication.HSE SOP-460:Field Site Exposure Monitoring <br /> D.15. SITE CONTAMINANTS, CHEMICAL WASTES Applicable Not Applicable, Not Anticipated <br /> D.16. RADIATION HAZARDS (Other than Sunlight) ❑ Applicable ® Not Applicable, Not Anticipated <br /> D.17, SHIPPING/TRANSPORTATION HAZMAT/DANGEROUS GOODS Applicable Not Applicable, Not Anticipated <br /> PART E-AIR MONITORING, WORKER EXPOSURE MONITORING <br /> E.1. AIR MONITORING Applicable Not Applicable, Not Anticipated <br /> Site-Specific Notes,Clarifications: <br /> AIR-TESTING PARAMETERS-Select site-specific testing parameters;list associated equipment in Part C.2,Safety Equipment List. <br /> ®VOCs E ❑02(Oxygen)—oxygen meter <br /> El Particulates-total dust meter <br /> ®PID(Photoionization detector): X eV ❑LEL(Lower Explosive Level)-LEL meter ❑%Methane—methane meter <br /> ❑FID(Flame ionization detector) ❑H2S(Hydrogen Sulfide)—H2S detector • ❑Calibration kit for each parameter <br /> ❑Colorimetric indicator tubes—describe above ❑CO(Carbon monoxide)—CO detector ❑Other: <br /> SUBSTANCE-SPECIFIC(PRE-SET)ACTION LEVELS-Sustained breathing zone action levels sustained general work-area levels for LEL). <br /> 02 19.5-23% Acceptable to continue work without 02-focused respiratory protection. <br /> El (Oxygen) <19.5% E STOP WORK,ventilate to raise 02 to>19.5%for re-entry. For persistent hazard,contact Corp.HSE Dept. <br /> aGeosyntec° Project/Task Name:Well Install,Development,and Destruction THA ver. <br /> ConsUltlnts THA Date: 04/17/2025 Page 13 <br />