Laserfiche WebLink
1.2.2 Sample Containers and Preservatives <br /> The laboratory will provide sample containers prior to sampling events. The containers <br /> will be pre-cleaned to meet USEPA standards and will not be rinsed in the field prior to <br /> sample collection. <br /> 1.3 Pre-Sampling Procedures <br /> Several steps will be conducted before samples are collected from the wells. These steps <br /> will ensure that instruments are functioning and properly calibrated, and that the <br /> necessary equipment has been supplied for efficient and accurate sampling. <br /> 1.3.1 Inventory <br /> The sampler will verify that the correct equipment is ready to be shipped to the field site, <br /> and that it is clean(decontaminated).The sampler will verify that the appropriate personal <br /> protective equipment and ancillary supplies (e.g., paper towels, decontamination <br /> solution) are ready to be shipped to the field site. The appropriate protective equipment <br /> will be reviewed during a morning tailgate meeting. The field supervisor or project <br /> manager will be contacted if there are discrepancies. <br /> 1.3.2 Calibration <br /> The field probes will be calibrated consistent with the manufacturer's specifications and <br /> the following requirements before sampling and at the start of each field day: <br /> 1. The pH probe will be calibrated using three points (pH = 4, 7, 10) using fresh <br /> calibration solutions; <br /> 2. The DO meter will be calibrated to moist air(100% saturation) and; <br /> 3. The ORP meter will be calibrated using calibration solutions; and <br /> 4. Specific conductance will be calibrated using calibration solutions. <br /> The sampler will record the calibration data on the field calibration record provided in <br /> this SOP or a similar field form. Instruments will be recalibrated as necessary(e.g.,when <br /> calibration checks indicate incorrect operation)to ensure accurate measurements, and all <br /> checks and recalibrations will be recorded on field calibration forms. If readings are <br /> suspect the calibration will be checked. <br />