My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKHEED
>
1941
>
2300 - Underground Storage Tank Program
>
PR0231891
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2026 8:17:33 PM
Creation date
9/19/2025 10:37:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231891
PE
2361 - UST FACILITY
FACILITY_ID
FA0003674
FACILITY_NAME
BANK OF STKN AIRPORT HANGAR #3
STREET_NUMBER
1941
Direction
E
STREET_NAME
LOCKHEED
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1941 E LOCKHEED CT STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A N MO N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> BANK OF STKN AIRPORT HANGAR#3 1941 E LOCKHEED CT, STOCKTON September 26, 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 10 CA Code of Regulations 2638(c), 2638(d) 2030074-Annual Monitoring System Certification Form to the CUPA within <br /> 30 days of completion of the test <br /> OBSERVATION: Annual monitoring system certification and leak detector testing was performed on October 2, 2024, <br /> and a test report was submitted on February 17, 2025. <br /> REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed in <br /> a timely manner. <br /> This is a (Minor)Violation. <br /> 13 CA Code of Regulations 2637.1(d), 2637.1(e) 2010017 - Spill bucket testing results submitted to the UPA within 30 <br /> days of testing <br /> OBSERVATION: Annual spill container testing was performed on October 2, 2024, and a test report was submitted on <br /> February 17, 2025. <br /> REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed in <br /> a timely manner. <br /> This is a (Minor)Violation. <br /> 14 CA Code of Regulations 2637.2(d&e), 2665(a&b) 2010018 - Overfill prevention equipment inspection report form <br /> submitted to the UPA within 30 days <br /> OBSERVATION: An overfill prevention equipment inspection was performed on October 2, 2024, and a test report was <br /> submitted on February 17, 2025. <br /> REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed in <br /> a timely manner. <br /> This is a Repeat(Class 2)Violation. <br /> 50 CA Code of Regulations 2635, 2637.1, 2665, 2712 2060020 - Spill buckets meet requirements, have been tested as <br /> required, and records kept for 36 mths (TCR 9a) <br /> OBSERVATION: The Jet Fuel spill container failed when tested. <br /> REGULATION GUIDANCE: All spill containers shall have a minimum capacity of five gallons and be capable of <br /> containing a spill or overfill until it is detected or cleaned up. <br /> CORRECTIVE ACTION: Immediately discontinue deposition of petroleum into this tank until the component is repaired or <br /> replaced by a properly licensed, trained, and certified contractor under permit and inspection of the EHD. If the spill <br /> container can't be replaced immediately, there is a possibility that the Jet Fuel UST system may be red tagged to prevent <br /> fuel inputs. <br /> This is a (Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 5 of 6 FA0003674 PR0231891 4556503 9/26/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.