My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2026 4:04:13 PM
Creation date
9/26/2025 1:41:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231952
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2905 W BENJAMIN HOLT DR STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN aOAQUIN Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION #94275* 12905 W BENJAMIN HOLT DR STOCKTON December 15 2025 <br /> 77 2712(f) 2030073-Facility has corrected cited violations within 30 days of receiving report ■OUT ❑ R ❑COS <br /> 78 2650(e), 2652 2030077-Owner/Operator notified/prepared report upon discovery of ❑ OUT ❑ R ❑ COS <br /> unauthorized release (TCR 9d) <br /> 79 2717.1(g) 2030045-Red Tag information is legible and has not been removed or tampered ❑ OUT ❑ R ❑ COS <br /> with <br /> 80 2717.1(f); HSC 25292.3 2030044-Facility did not deposit/allow deposit of petroleum or a hazardous ❑ OUT ❑ R ❑ COS <br /> (c) substance into a red tagged UST <br /> 81 25292.3(c)(1)(C) 2030079-Facility did not dispense petroleum or a hazardous substance from a ❑ OUT ❑ R ❑ COS <br /> UST that has been red tagged <br /> 82 2670(b)(e)(f), 2671 2030063-Facility is in compliance with temporary closure requirements ❑ OUT ❑ R ❑ COS <br /> 83 25298(c); CCR 2670, 2030038-UST system properly closed and complies with permanent closure ❑ OUT ❑ R ❑ COS <br /> 2672 requirements <br /> 84 25392.4(d),25292.5(c) 2030066-Repaired/retested any leaks found when ELD testing a UST within ❑ OUT ❑ R ❑ COS <br /> 1,000 feet of a public water well <br /> 85 2631(a); HSC 25290.1(c) 2060027-Tank system primary containment is constructed, operated, and ❑ OUT ❑ R ❑ COS <br /> maintained product-tight. <br /> 86 2631.1, 2660(m) 2060024-UST system is made of or lined with materials that are compatible with ❑ OUT ❑ R ❑ COS <br /> the substance stored. <br /> 87 2631(c), 2662(d) 2060021 -Striker plate installed and positioned correctly. ❑ OUT ❑ R ❑ COS <br /> 88 2631(b&d), 2666(b&e) 2060007-Primary and secondary containment designed and constructed to an ❑ OUT ❑ R ❑ COS <br /> engineering specification. <br /> 89 25290.1(j) 2060008-Enhanced leak detection testing performed before the tank is placed in ❑ OUT ❑ R ❑ COS <br /> use <br /> 90 2666(b)(2) 2060029-SW piping has been upgraded to continuously monitored DW piping ❑ OUT ❑ R ❑ COS <br /> when replacement or repair needed <br /> 91 25291(e) 2010-Administration/Documentation-General ❑ OUT ❑ R ❑ COS <br /> 92 - 2015-Administrative/Documentation-General Local Ordinance ❑ OUT ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 5 2632(d), 2641(h) 2030041 -A current facility plot plan is maintained and has been submitted <br /> OBSERVATION: An accurate UST Monitoring Site Plan (map)was not submitted. The map showed two monitoring <br /> panels -only one panel was located on site. The location of the panel in the back room as identified on the map is not in <br /> the correct location. A list of vacuum zones was included with the map, which did not match the panel vacuum zone <br /> programming/labeling and did not include the diesel vent piping. <br /> REGULATION GUIDANCE: A monitoring site plan (map) must include: 1) a scaled diagram indicating the layout of the <br /> tank(s), sumps, and piping to the extent known; 2) locations of all release detection equipment; and 3) if applicable, each <br /> vacuum, pressure, or hydrostatic interstitial monitoring zone. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> **Please note, the UST Monitoring Site Plan (map) requirements have changed, effective January 1, 2026. In order to <br /> ensure the map submitted meets current requirements, the requirements listed under'Regulation Guidance' above are <br /> based on 2026 regulations. <br /> This is a (Minor)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 4 of 7 FA0003712 PR0231952 4588104 1/28/2026 <br /> CP22-U aST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.