My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2026 4:04:13 PM
Creation date
9/26/2025 1:41:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231952
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2905 W BENJAMIN HOLT DR STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN aOAQUIN Environmental Health Department <br /> COUNTY— <br /> Greatness#rows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION #94275" 12905 W BENJAMIN HOLT DR STOCKTON December 15 2025 <br /> 10 2638(c), 2638(d) 2030074-Annual Monitoring System Certification Form to the CUPA within 30 days of completion of <br /> the test <br /> OBSERVATION: According to work orders and test results found on site, a monitoring system certification for the S1 (87 <br /> product) sensor replacement was performed on 9/10/25. A test report has not been submitted to the EHD or the <br /> California Environmental Reporting System (CERS). <br /> REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the test. <br /> CORRECTIVE ACTION: Immediately provide this report to the EHD. <br /> This is a (Minor)Violation. <br /> 28 2638(a), 26410) 2030043- Leak detection equipment properly installed, calibrated, operated, and maintained (TCR 9d) <br /> OBSERVATION: <br /> 1) The panel programming (labeling)for vacuum sensors does not match the labeling on the "vacuum smart sensor <br /> table" provided with the monitoring site plan, nor the set up of the sensors on site. Each vent line was observed being <br /> monitored by its own smart sensor. The panel has S19 labeled as "all vents". The vent sump is not identified. The <br /> individual vent piping for the three products is not listed on any other sensors. According to the "vacuum smart sensor <br /> table" S19 is "supreme vent line-vent sump". <br /> 2)All vent lines were observed being monitored by separate vacuum sensors in their individual STP sumps. They were <br /> also observed manifolded together by a fitting inside the vent sump, indicating each vent line is connected to three <br /> separate vacuum sensors. The Veeder-Root vacuum sensor manual indicates "one each is required" of secondary piping <br /> vacuum monitoring kits for piping monitoring. <br /> REGULATION GUIDANCE: All monitoring equipment shall be installed, calibrated, operated, and maintained in <br /> accordance with manufacturer's instructions, and certified for operability, proper operating condition, and proper <br /> calibration. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed and certified contractor to ensure vacuum zones are <br /> properly monitored, under permit and inspection by EHD if necessary. Ensure that all leak detection equipment is <br /> properly programmed and maintained at all times. <br /> This is a Repeat (Class 2)Violation. <br /> 35 25290.1(e) 2030065- Interstitial space of the UST is under constant VPH monitoring (TCR 9d) <br /> OBSERVATION: <br /> 1) The S4 (87 STP sump)vacuum sensor failed when tested. <br /> 2) The S1 (87 product)vacuum sensor was in no vacuum alarm from 8/14/25 until 9/10/25, and was incapable of <br /> detecting a leak during this time. According to the work order and test result on site, the sensor was replaced on 9/10/25, <br /> clearing the alarm. <br /> REGULATION GUIDANCE: The interstitial space of the UST shall be maintained, as designed, under constant vacuum <br /> or pressure such that a breach in the primary or secondary containment is detected before the hazardous substance is <br /> released into the environment. <br /> CORRECTIVE ACTION: The S4 sensor was replaced and retested during the inspection. Ensure all sensors are <br /> maintained functional and capable of detecting a breach in the primary or secondary containment before the hazardous <br /> substance is released to the environment. <br /> This is a Repeat (Class 2)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 5 of 7 FA0003712 PR0231952 4588104 1/28/2026 <br /> CP22-U aST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.