My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
1420
>
2300 - Underground Storage Tank Program
>
PR0231736
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2026 8:06:38 PM
Creation date
11/7/2025 10:04:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231736
PE
2361 - UST FACILITY
FACILITY_ID
FA0002562
FACILITY_NAME
SUTTER TRACY COMMUNITY HOSPITAL
STREET_NUMBER
1420
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23308101
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1420 N TRACY BLVD TRACY 95376
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: I Facility Address: Date: <br /> Sutter Vallev Hospitals dba Sutter Tracv Communit 11420 N Tracv BLVD, Tract/ TNovember 13, 2025 <br /> 21 2637, 2638(e), 2643(g) 2030064-CUPA was notified within 48 hours prior to testing ❑OUT ❑ R ❑COS <br /> 22 2640(e), 2644.1 2030068- Initial or triennial ELD testing conducted on UST system 1 000'of public ❑OUT ❑ R ❑COS <br /> well <br /> 23 2635(e)(8) 2060001 -As-built plans for new installations and/or with the permit application ❑OUT ❑ R ❑COS <br /> have been submitted <br /> 24 2632(c), 2634(d), 2636(f) 2030003- Leak detection system maintains continuous monitoring that activates ❑OUT ❑ R ❑COS <br /> an audible and visual alarm <br /> 25 2631(g), 2632(c)(2) 2030016-Annular space of USTs are continuously monitored with an audible and ❑OUT ❑ R ❑COS <br /> visual alarm system (TCR 9d) <br /> 26 2636(f)(4) 2030017- Piping out of UDC is fail-safe/shut down, UDC leak shuts off pump/flow, ❑OUT ❑ R ❑COS <br /> or tightness test(TCR 9d) <br /> 27 2666(b)(2), 2636(f)(1) 2030018-DW press piping is monitored with an audible/visual alarm or stops flow ❑OUT ❑ R ❑COS <br /> at UDC(TCR 9d) <br /> 28 2638(a), 26416) 2030043-Leak detection equipment properly installed, calibrated, operated, and ❑OUT ❑ R ❑COS <br /> maintained (TCR 9d) <br /> 29 2636(a)(1), 25291(b) 2060005- UST system constructed with a mon system capable of detecting entry ❑OUT ❑ R ❑COS <br /> into secondary containment <br /> 30 2630(d), 2641(a) 2060015-Leak detection equipment located so leak is detected at the earliest ❑OUT ❑ R ❑COS <br /> possible opportunity(TCR 9d) <br /> 31 25299(a)(9) 2030062-Leak detection equipment has not been tampered with or disabled (TCR ❑OUT ❑ R ❑COS <br /> 9d) <br /> 32 2636(f), 2666(c), 2666(f) 2030075-E Gen System LLD detects 3 gph leak&restricts/shuts off flow or ❑OUT ❑ R ❑COS <br /> activates and/vis alarm (TCR 9d) <br /> 33 25290.2(d) 2060022-System has a mon system capable of detecting entry of haz sub or ❑OUT ❑ R ❑COS <br /> water into secondary containment <br /> 34 2638(f), 2641 Q) 2030034-Tag/sticker on affixed monitoring equipment being certified, repaired, or ❑OUT ❑ R ❑COS <br /> replaced <br /> 35 25290.1(e) 2030065- Interstitial space of the UST is under constant VPH monitoring (TCR 9d) ❑OUT ❑ R ❑COS <br /> 36 25290.1(d) 2060023-System has a mon system that can detect entry of haz sub liquid/vapor, ❑OUT ❑ R ❑COS <br /> or water into sec contain <br /> 37 2635, 2636(b), 2662, 2030009-Cathodic protection is installed/maintained as required, including ❑OUT ❑ R ❑COS <br /> 2712 required documentation (TCR 9c) <br /> 38 2643(b)(3) 2030005-SW tank continuous in tank leak detection test is functioning properly ❑OUT ❑ R ❑COS <br /> (TCR 9d) <br /> 39 2643(b)(1) 2030006- Monthly 0.2 gph ATG test is being conducted and copies of test results ❑OUT ❑ R ❑COS <br /> are available(TCR 9d) <br /> 40 2060002-SW UST system has monitoring system capable of detecting releases ❑OUT ❑ R ❑COS <br /> (TCR 9d) <br /> 41 2647, 2648,2712(b)(4) 2030022-Groundwater and/or vadose zone monitoring conducted, or site ❑OUT ❑ R ❑COS <br /> assessment maintained (TCR 9d) <br /> 42 2643(c), 2661(f) 2030052-.2 gph mthly or.1 gph yrly tests performed on piping, and .1 gph w/in 30 ❑OUT ❑ R ❑COS <br /> days of repair(TCR 9d) <br /> 43 2636, 2643(c)(1), 2666(f) 2060012- LLD installed on pressurized piping system (TCR 9d) ❑OUT ❑ R ❑COS <br /> 44 2643(c)(1), 2666(c) 2030027-LLD on SW press piping tests hrly, detects 3 gph leak, shuts down ❑OUT ❑ R ❑COS <br /> pump if leak or LLD fails (TCR 9d) <br /> 45 2636(f)(2) 2030025- LLD on DW press piping monitors hrly, detects a 3.0 gph leak, and ❑OUT ❑ R ❑COS <br /> restricts/shuts off flow(TCR 9d) <br /> 46 2636(a)(3), 2641(b) 2030053-SW Safe Suction piping drains back into storage tank, one check valve ❑OUT ❑ R ❑COS <br /> and inspections conducted <br /> 47 25290.1(c3), 25290.2(c3) 2030008-Secondary containment installed after July 1, 2003 is free of water ❑OUT ❑ R ❑COS <br /> 48 2630(d), 2641(a) 2030040-Secondarily contained piping allows liquid to flow into the sump in the ❑OUT ❑ R ❑COS <br /> event of a leak(TCR 9d) <br /> EHD-CUPA Inspection Report IS02 Page 2 of 5 FA0002562 PR0231736 4576491 11/13/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.