PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003732
FACILITY_NAME
GAVINKO PETROLEUM*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
7700 MORELAND ST STOCKTON 95212
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN AMENDED Environmental Health Department <br /> COUNTY— 1/8/2026 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GAVINKO PETROLEUM* 17700 MORELAND ST, STOCKTON TlOctober 16, 2025 <br /> 77 2712(f) 2030073-Facility has corrected cited violations within 30 days of receiving report ❑ OUT ❑ R ❑ COS <br /> 78 2650(e), 2652 2030077-Owner/Operator notified/prepared report upon discovery of ❑ OUT ❑ R ❑ COS <br /> unauthorized release (TCR 9d) <br /> 79 2717.1(g) 2030045-Red Tag information is legible and has not been removed or tampered ❑ OUT ❑ R ❑ COS <br /> with <br /> 80 2717.1(f); HSC 25292.3 2030044- Facility did not deposit/allow deposit of petroleum or a hazardous ❑ OUT ❑ R ❑ COS <br /> (c) substance into a red tagged UST <br /> 81 25292.3(c)(1)(C) 2030079-Facility did not dispense petroleum or a hazardous substance from a ❑ OUT ❑ R ❑ COS <br /> UST that has been red tagged <br /> 82 2670(b)(e)(f), 2671 2030063- Facility is in compliance with temporary closure requirements ❑ OUT ❑ R ❑ COS <br /> 83 25298(c); CCR 2670, 2030038-UST system properly closed and complies with permanent closure ❑ OUT ❑ R ❑ COS <br /> 2672 requirements <br /> 84 25392.4(d), 25292.5(c) 2030066-Repaired/retested any leaks found when ELD testing a UST within ❑ OUT ❑ R ❑ COS <br /> 1,000 feet of a public water well <br /> 85 2631(a); HSC 25290.1(c) 2060027-Tank system primary containment is constructed, operated, and ❑ OUT ❑ R ❑ COS <br /> maintained product-tight. <br /> 86 2631.1, 2660(m) 2060024- UST system is made of or lined with materials that are compatible with ❑ OUT ❑ R ❑ COS <br /> the substance stored. <br /> 87 2631(c), 2662(d) 2060021 -Striker plate installed and positioned correctly. ❑ OUT ❑ R ❑ COS <br /> 88 2631(b&d), 2666(b&e) 2060007-Primary and secondary containment designed and constructed to an ❑ OUT ❑ R ❑COS <br /> engineering specification. <br /> 89 25290.10) 2060008-Enhanced leak detection testing performed before the tank is placed in ❑ OUT ❑ R ❑ COS <br /> use <br /> 90 2666(b)(2) 2060029-SW piping has been upgraded to continuously monitored DW piping ❑ OUT ❑ R ❑COS <br /> when replacement or repair needed <br /> 91 25291(e) 2010-Administration/Documentation-General ❑ OUT ❑ R ❑ COS <br /> 92 - 2015-Administrative/Documentation-General Local Ordinance ❑ OUT ❑ R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 3 2632(d)(1), 2634(d) 2010013 - Facility has submitted a complete and accurate UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not approved by the EHD. <br /> 1.) For the Premium and Regular Tanks-> In the monitoring plan the "ELLD Model" is listed as 84-84-01, this is incorrect. <br /> The correct model is 848480-001 or it can be listed as 8484 to represent the series name. <br /> 2.) For all 3 tanks-> In the monitoring plan, the names listed under"Personnel Responsibilities" are the names of the <br /> former owners, please update. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting System <br /> (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 4 of 7 FA0003732 PR0231819 4565085 1/8/2026 <br /> CP22-UST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.