7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2026 2:17:16 PM
Creation date
1/15/2026 7:41:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231819
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003732
FACILITY_NAME
GAVINKO PETROLEUM*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
7700 MORELAND ST STOCKTON 95212
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report <br />Date: <br />October 16, 2025 <br />Facility Address: <br />7700 MORELAND ST, STOCKTONGAVINKO PETROLEUM* <br />Facility Name: <br />Environmental Health DepartmentAMENDED <br />1/8/2026 <br />77 2712(f)2030073 - Facility has corrected cited violations within 30 days of receiving report o OUT o R o COS <br />78 2650(e), 2652 2030077 - Owner/Operator notified/prepared report upon discovery of <br />unauthorized release (TCR 9d) <br />o OUT o R o COS <br />79 2717.1(g)2030045 - Red Tag information is legible and has not been removed or tampered <br />with <br />o OUT o R o COS <br />80 2717.1(f); HSC 25292.3 <br />(c) <br />2030044 - Facility did not deposit/allow deposit of petroleum or a hazardous <br />substance into a red tagged UST <br />o OUT o R o COS <br />81 25292.3(c)(1)(C)2030079 - Facility did not dispense petroleum or a hazardous substance from a <br />UST that has been red tagged <br />o OUT o R o COS <br />82 2670(b)(e)(f), 2671 2030063 - Facility is in compliance with temporary closure requirements o OUT o R o COS <br />83 25298(c); CCR 2670, <br />2672 <br />2030038 - UST system properly closed and complies with permanent closure <br />requirements <br />o OUT o R o COS <br />84 25392.4(d), 25292.5(c)2030066 - Repaired/retested any leaks found when ELD testing a UST within <br />1,000 feet of a public water well <br />o OUT o R o COS <br />85 2631(a); HSC 25290.1(c)2060027 - Tank system primary containment is constructed, operated, and <br />maintained product-tight. <br />o OUT o R o COS <br />86 2631.1, 2660(m)2060024 - UST system is made of or lined with materials that are compatible with <br />the substance stored. <br />o OUT o R o COS <br />87 2631(c), 2662(d)2060021 - Striker plate installed and positioned correctly.o OUT o R o COS <br />88 2631(b&d), 2666(b&e)2060007 - Primary and secondary containment designed and constructed to an <br />engineering specification. <br />o OUT o R o COS <br />89 25290.1(j)2060008 - Enhanced leak detection testing performed before the tank is placed in <br />use <br />o OUT o R o COS <br />90 2666(b)(2)2060029 - SW piping has been upgraded to continuously monitored DW piping <br />when replacement or repair needed <br />o OUT o R o COS <br />91 25291(e)2010 - Administration/Documentation - General o OUT o R o COS <br />92 -2015 - Administrative/Documentation - General Local Ordinance o OUT o R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item #Remarks <br />3 2632(d)(1), 2634(d) 2010013 - Facility has submitted a complete and accurate UST Monitoring Plan. <br />OBSERVATION: The monitoring plan is not approved by the EHD. <br />1.) For the Premium and Regular Tanks -> In the monitoring plan the "ELLD Model" is listed as 84-84-01, this is incorrect. <br />The correct model is 848480-001or it can be listed as 8484 to represent the series name. <br />2.) For all 3 tanks -> In the monitoring plan, the names listed under "Personnel Responsibilities" are the names of the <br />former owners, please update. <br />REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting System <br />(CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br />This is a Repeat (Class 2) Violation. <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 4 of 7EHD - CUPA Inspection Report IS03 <br />CP22 - UST FULL <br />1/8/2026FA0003732 PR0231819 4565085
The URL can be used to link to this page
Your browser does not support the video tag.