My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SNEDEKER
>
809
>
2200 - Hazardous Waste Program
>
PR0527608
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2026 6:51:55 PM
Creation date
2/5/2026 11:44:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0527608
PE
2220 - SM HW GEN <5 TONS/YR
FACILITY_ID
FA0018706
FACILITY_NAME
CANARY RENEWABLES CORP
STREET_NUMBER
809
STREET_NAME
SNEDEKER
STREET_TYPE
AVE
City
STOCKTON
Zip
95203
APN
16203007
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
809 C SNEDEKER AVE STOCKTON 95203
Suite #
C
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STI SP001 Monthly Inspection Checklist <br /> General Ins ection Information: <br /> Inspection Date: 12/20/22 12/20/25 (36 months from inspection date) <br /> Retain Until Date: <br /> Prior Inspection Date: 1 1/18/22 Inspector Name: Patrick Samson <br /> —�_ <br /> Tanks Inspected(ID#'s): T-611 T-612 T-615 T-616, T-617, T-618, T-619 <br /> Inspection Guidance: <br /> ➢ For equipment not included in this Standard,follow the manufacturer recommended inspection/testing schedules and <br /> procedures. <br /> 1- The periodic AST Inspection is intended for monitoring the external AST condition and its containment structure.This visual <br /> inspection does not require a Certified Inspector. It shall be performed by an owner's inspector who is familiar with the site and <br /> can identify changes and developing problems. <br /> ➢ Upon discovery of water in the primary tank, secondary containment area, interstice, or spill container, remove promptly or take <br /> other corrective action. Before discharge to the environment, inspect the liquid for regulated products or other contaminants and <br /> disposed of it properly. <br /> ➢ (*) designates an item in a non-conformance status. This indicates that action is required to address a problem. <br /> ➢ Non-conforming items important to tank or containment integriit require evaluation by an engineer experienced in AST design, a <br /> Certified Inspector, or a tank manufacturer who will determine the corrective action. Note the non-conformance and <br /> corresponding corrective action in the comment section. <br /> ➢ Retain the completed checklists for 36 months. <br /> ➢ In the event of severe weather(snow, ice,wind storms)or maintenance(such as painting)that could affect the <br /> operation of critical components(normal and emergency vents,valves), an inspection of these components is required <br /> as soon as the equipment is safely accessible after the event. <br /> Item Task Status Comments <br /> 1.0 T nk Containment <br />` 1.1 Containment Check for water, iYes* o ❑N/A <br />�J structure debris, cracks or fire <br /> hazard <br /> 1.2 Primary tank Check for water Yes* o <br /> 1.3 Containment Operable and in a Wes ❑No* ❑N/A <br /> drain valves closed position <br /> 1.4 Pathways and Clear and es []No* �,N/A <br /> entry gates/doors <br /> operable <br /> 2.0 Leak Detection <br /> 2.1 Tank Visible signs of Yes* o <br /> leakage <br /> 2.2 Secondary Visible signs of ❑Yes* INo <br /> Containment leakage from tank <br /> into secondary <br /> containment <br /> 2.3 Surrounding soil Visible signs of i iYes* o ❑N/A <br /> leakage <br /> 2.4 Interstice Visible signs of i iYes* rMo ❑N/A <br /> leakage <br /> 3.0 Tank Equipment <br /> 3.1 Valves a. Check for leaks. ,es* i o CiN/A <br /> b. Tank drain valves es* nNo i iN/A <br /> must be kept locked. <br /> 3.2 Spill a. Inspect for debris, Yes* []No N/A <br /> containment residue, and water in <br /> boxes on fill the box and remove. <br /> b. Drain valves must ❑Yes" []NoN/A <br /> pipe be operable and <br /> closed. <br /> AST INSPECTION STANDARD <br /> 1 SEPTEMBER 2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.