COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4405
>
2200 - Hazardous Waste Program
>
PR0521599
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2026 11:40:19 AM
Creation date
2/7/2026 10:16:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0521599
PE
2220 - SM HW GEN <5 TONS/YR
FACILITY_ID
FA0007787
FACILITY_NAME
7-ELEVEN INC #41341
STREET_NUMBER
4405
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11024013
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
4405 PACIFIC AVE STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANsJOAQUIN Environmental Health Department <br /> COUNTY— <br /> Small Quantity Hazardous Waste Generator Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 7-ELEVEN INC#41341 14405 PACIFIC AVE, STOCKTON June 13, 2025 <br /> 48 CA Code of Regulations 66262.34(d)(2) 3010022 - Posted emergency information next to the telephone <br /> OBSERVATION: Modified contingency plan information was not posted at the facility. <br /> REGULATION GUIDANCE: The business operator must post the following information next to telephones or in areas <br /> directly involved in the generation and accumulation of hazardous waste: the name and emergency telephone number of <br /> the emergency coordinator, the location of fire extinguishers and spill control material, and the telephone number of the <br /> fire department unless the facility has a direct alarm. <br /> CORRECTIVE ACTION: Immediately post the modified contingency plan information or keep a copy of a complete <br /> consolidated emergency response/contingency plan on-site. Provide a statement to the San Joaquin County <br /> Environmental Health Department that the correction is complete. <br /> This is a Repeat(Class 2)Violation. <br /> 50 CA Code of Regulations 66262.34(d)(2) 3030032 - Facility equipped with all required emergency equipment <br /> OBSERVATION: The facility is not equipped with the following equipment: <br /> -A spill kit was not observed. The employees stated that they previously had absorbent but they used it and ran out <br /> several weeks ago. <br /> -Hazardous waste storage drums were not observed on site. The employees stated they were stolen several weeks ago <br /> and that the manager plans to discuss it with the district manager but has not yet done so. <br /> REGULATION GUIDANCE: All facilities shall be equipped with the following, unless it can be demonstrated to the <br /> Department that none of the hazards posed by waste handled at the facility could require a particular kind of equipment <br /> specified below: <br /> (a) an internal communications or alarm system capable of providing immediate emergency instruction (voice or signal) <br /> to facility personnel; <br /> (b) a device, such as a telephone (immediately available at the scene of operations)or a hand-held two-way radio, <br /> capable of summoning emergency assistance from local police departments, fire departments, or State or local <br /> emergency response teams; <br /> (c) portable fire extinguishers, fire control equipment(including special extinguishing equipment, such as that using foam, <br /> inert gas, or dry chemicals), spill control equipment, and decontamination equipment; and <br /> (d)water at adequate volume and pressure to supply water hose streams, or foam producing equipment, or automatic <br /> sprinklers, or water spray systems . <br /> CORRECTIVE ACTION: Immediately install the following equipment: spill kits and hazardous waste storage containers. <br /> Provide a corrective action statement and supporting documentation to the San Joaquin County Environmental Health <br /> Department within 30 days. <br /> This is a (Class 2)Violation. <br /> 51 CA Code of Regulations 66262.34(d)(2) 3030034 -Tests and maintains all required safety equipment at the facility <br /> OBSERVATION: The eyewash station fluids observed on site are expired. <br /> REGULATION GUIDANCE: All facility communications or alarm systems, fire protection equipment, spill control <br /> equipment, and decontamination equipment, where required, shall be tested and maintained as necessary to assure its <br /> proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the eyewash station into proper working order by repair, replacement or testing. Provide <br /> a corrective action statement to the San Joaquin County Environmental Health Department within 30 days. <br /> This is a (Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 5 of 6 FA0007787 PRO521599 4517104 6/13/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.