My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3081
>
2900 - Site Mitigation Program
>
PR0541231
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2026 9:53:04 AM
Creation date
2/27/2026 9:19:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0541231
PE
2959 - DTSC LEAD AGENCY SITE
FACILITY_ID
FA0023619
FACILITY_NAME
FORMER QUALITY CLEANERS TRACY CORNERS SHOPPING CENTER
STREET_NUMBER
3081
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418041
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
3081 N TRACY BLVD TRACY 95376
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
549
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The instruments and equipment will receive routine preventative maintenance. At a minimum, all <br /> instruments (including backup) will be inspected for usable condition and calibration status prior to each <br /> field use. <br /> 10.0 INSPECTION/ACCEPTANCE OF SUPPLIES AND CONSUMABLES <br /> Prior to acceptance, all supplies and consumables will be inspected by the contractor's assigned personnel <br /> to ensure that they are in satisfactory condition, are free of defects, and are free of potential sources of <br /> contamination with chemical compounds of interest. If defects are noted, the item will be replaced. The <br /> FPM or designated environmental personnel will inspect all supplies and consumables provided by <br /> subcontractors, including laboratories. <br /> 11.0 NON-DIRECT MEASUREMENTS <br /> Non-direct measurements include information from logbooks, site documents, photographs, topographic <br /> maps, and data from other sources that may be used to augment the dataset collected under this project <br /> and to assist in decision-making. The logbooks, data sheets, photographs, and topographic maps <br /> generated or utilized by the environmental contractor will be documented as specified in this QA/QC Plan. <br /> Information from external sources will be evaluated for any limitation on the data use and will be <br /> incorporated into project documents with concurrence of the project team, including DTSC. These sources <br /> will be identified in any project reporting documents and these documents will include relevant <br /> information on any such sources, including the original generator, associated QC, and limitations on use. <br /> 12.0 DATA MANAGEMENT <br /> Each data package and associated QA/QC information received from the State-certified analytical <br /> laboratory will be reviewed to confirm that data quality objectives have been met. The parameters to be <br /> reviewed will include: <br /> • Sample holding times; <br /> • Blank data; <br /> • Field duplicate data; <br /> • Surrogate recovery data; <br /> • MS/MSD data; and <br /> • Remarks provided by the laboratory. <br /> The sample holding times will be reviewed to ensure that the requested analyses were completed within <br /> the specified holding times for those analyses. The analytical results of field and/or laboratory blank <br /> samples that were analyzed will be checked for evidence of potential contamination. Accuracy of the <br /> reported results will be evaluated by checking the surrogate recoveries, and the MS/MSD spike recoveries <br /> against the specified QC criteria for the method. The precision of the reported results will be evaluated by <br /> checking the results of the MS/MSD, field duplicate and laboratory duplicate samples. <br /> Quality Assurance/Quality Control Plan <br /> Tracy Corners Shopping Center <br /> 3225 North Tracy Boulevard <br /> Tracy,California 95376 <br /> Partner Project Number SM14-129814 <br /> Docket Number HAS-VCA 14/15-108 <br /> August 15,2016 <br /> Page 13 <br />