My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3081
>
2900 - Site Mitigation Program
>
PR0541231
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2026 9:53:04 AM
Creation date
2/27/2026 9:19:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0541231
PE
2959 - DTSC LEAD AGENCY SITE
FACILITY_ID
FA0023619
FACILITY_NAME
FORMER QUALITY CLEANERS TRACY CORNERS SHOPPING CENTER
STREET_NUMBER
3081
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418041
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
3081 N TRACY BLVD TRACY 95376
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
549
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6.3 Proposed Vapor Intrusion Assessment <br /> A vapor intrusion assessment will consist of indoor and outdoor air samples and soil gas samples <br /> from sub-slab probes and a five-foot deep soil gas probe that will be collected during the same <br /> sampling event. <br /> 6.3.1 Proposed Indoor Air Sampling Methods <br /> Indoor air sampling is part of the step-wise approach of the assessment of intrusion of subsurface <br /> vapors into buildings as promulgated in the October 2011 DTSC technical document titled Final <br /> Guidance for the Evaluation and Mitigation of Subsurface Vapor Intrusion in Indoor Air (Vapor <br /> Intrusion Guidance). The proposed indoor air sampling will be conducted at the Quality Cleaners, <br /> the Fred Loya Insurance office (3085 North Tracy Boulevard and the adjacent tenant west of <br /> Quality Cleaners)and the Comcast store(3115 North Tracy Boulevard and the adjacent tenant east <br /> of Quality Cleaners). <br /> At least two weeks prior to indoor air sampling, on-site managers of the three suites will be <br /> contacted in person to inspect the suites for potential sources of VOCs, schedule the testing and to <br /> explain the testing procedures. Also,written instructions will be provided. The instructions should <br /> state that use of certain consumer products is discouraged due to potential biasing of the sampling <br /> results. <br /> After performing the inspections, Partner will place two six-liter Summa canisters in each of the <br /> three suites in locations diagrammatically shown on Figure 5. It is the intent of this task to include <br /> the number of indoor air samples that will be appropriate for the internal configuration and use of <br /> each suite. Indoor air samples will be collected in primary work areas as well as possible vapor <br /> entry locations(e.g.,utility entrances in the stockroom or floor drains found in restrooms or boiler <br /> rooms). The canisters will be placed at a height of three to five feet above the floor. The actual <br /> locations of the indoor air samples will be based on the inspections that will occur at least two weeks <br /> in advance of the field sampling event and the proposed locations will be conveyed to DTSC staff <br /> for concurrence. <br /> A single canister will be located to the southwest exterior(anticipated upwind location)of the target <br /> suites to assess target compounds in outdoor air. The canisters will have flow regulators set to allow <br /> the air samples to be collected over a 24-hour period. <br /> In accordance with the Vapor Intrusion Guidance, soil gas should be sampled at a frequency that <br /> allows detection of seasonal variation and other temporal changes and to determine long-term <br /> stability of constituent concentrations. Therefore, a follow-up sampling for indoor air will be <br /> tentatively scheduled for approximately six months after the initial indoor sampling is <br /> Sampling and Analysis Workplan <br /> Tracy Corners Shopping Center <br /> 3225 North Tracy Boulevard <br /> Tracy,California 95376 <br /> Partner Project Number SM14-129814 <br /> Docket Number HAS-VCA 14/15-108 <br /> August 15,2016 <br /> Page 22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.