Laserfiche WebLink
Stockton Propeller Sampling and Analysis Plan <br /> 2.4 Sensitive Receptors <br /> According to the Department of Water Resources (DWR) Well Completion Report Map <br /> (https://www.arcgis.com/apps/webappviewer/index.htm I?id=18107858Oa214cO986e2da28f8623b37) <br /> there are numerous wells within approximately one (1) mile radius of the SPI facility as shown in Table 3 <br /> below.These numbers are an overestimate of the number of wells within one (1) mile of the facility as <br /> these are the total number of wells within the surrounding Public Land Survey System (PLSS) Sections. <br /> Exact numbers for a one (1) mile radius cannot currently be determined using the DWR Well Completion <br /> Report Map. <br /> Table 3. Estimated Number of Wells Near the SPI Facility <br /> Township, Number of Number of Number of Min Depth Average Depth <br /> Range& Domestic Wells Production Wells Public Wells (ft bgs) (ft bgs) <br /> Section <br /> 2N7E30 (site) 40 8 2 129 212 <br /> 2N7E29 53 11 0 176 249 <br /> 2N7E32 19 9 2 131 225 <br /> 2N7E31 7 3 3 150 192 <br /> 2.5 Depth to Groundwater <br /> According the Department of Water Resources (DWR)Sustainable Groundwater Management Act <br /> (SGMA) Data Viewer(https://sgma.water.ca.gov/webgis/?appid=SGMADataViewer#currentconditions), <br /> the depth to groundwater in the vicinity of the site was approximately 65 ft below ground surface (BGS) <br /> in the spring of 2021. Refer to Figure 4. <br /> Blankinship&Associates, Inc. Page 10 of 20 September 23, 2022 <br /> NES, Inc. <br />