My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2026 12:25:39 PM
Creation date
3/20/2026 3:12:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0440005
PE
4433 - LANDFILL DISPOSAL SITE
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
201060013, 5
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
9999 AUSTIN RD MANTECA 95336
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Brendan P. Kenny, RG <br /> Corrective Action Program Update - 1 Q2026 <br /> April 13, 2026 <br /> Page 2 <br /> Gas Probe Observed Methane Concentration <br /> GP-lAD 3.6%by volume <br /> GP-lOD 54.0%by volume, <br /> GP-10M 56.3%by volume <br /> GP-10S 56.3%by volume <br /> GP-11M 3%by volume <br /> GP-11S 7.8%by volume <br /> On 9 February 2026, the following gas probes had VOC exceedances above 10 ppbv: <br /> Gas Probe Observed VOC Exceedances <br /> GP-lOD 1,900 ppbv <br /> GP-10M 1,900 ppbv <br /> GP-10S 2,800 ppbv <br /> GP-11S 4,500 ppbv <br /> Based on the requirements in the CAO and on the monitoring results, probes GP-IAD, GP-IOD, <br /> GP-1 OM, GP-1 OS, GP-11 M and GP-11 S will require annual TO-15 sampling due to methane <br /> concentrations exceeding 1 percent by volume and/or VOC concentrations exceeding 10 ppbv. <br /> The TO-15 sampling of these probe intervals will be conducted on an annual basis in accordance <br /> with the CAO and submitted as part of the Landfill Gas Extraction System Optimization Report. <br /> CONTROL SYSTEM PERFORMANCE MONITORING <br /> The site sends its LFG to two onsite flares for combustion and to the onsite landfill gas to energy <br /> (LFGTE)plant operated by Ameresco. SCS operated and monitored the GCCS including the flares <br /> in the first quarter of 2026. <br /> The average flow rates to FL-100 and FL-150 were 1,252 scfm and 1,565 scfin, respectively. The <br /> average methane content was 52.5%volume at flare FL-100 and 52.3% at flare FL-150. <br /> Flare FL-100 had a total run time of 742.57 hours and a total downtime of 1.43 hours in January <br /> 2026, a total run time of 671.38 hours and a total downtime of 0.62 hour in February 2026 and, a <br /> total run time of 743 hours and a downtime of 1 hour in March 2026. The total downtime during <br /> the quarter was 0.4%. During the first quarter of 2026, the maximum adjusted flow recorded at <br /> Flare FL-100 was 3,793 standard cubic feet per minute (scfin). <br /> Flare FL-150 had a total runtime of 741.33 hours and a total downtime of 2.67 hours in January <br /> 2026, a total run time of 671.4 hours and downtime of 0.6 hour in February 2026 and, a total <br /> runtime of 743 hours and down time of 1 hour in March 2026. The total downtime during the <br /> Q 1 Corrective Action Program Update-2026 <br /> engineers I scientists I innovators <br />
The URL can be used to link to this page
Your browser does not support the video tag.