My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024-2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACACIA
>
525
>
4500 – Medical Waste Program
>
PR0450001
>
COMPLIANCE INFO_2024-2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2026 2:16:44 PM
Creation date
3/24/2026 2:03:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4500 – Medical Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024-2026
RECORD_ID
PR0450001
PE
4522 - ACUTE CARE FACILITY
FACILITY_ID
FA0002864
FACILITY_NAME
DAMERON HOSPITAL
STREET_NUMBER
525
Direction
W
STREET_NAME
ACACIA
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13715304
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
525 W ACACIA ST STOCKTON 95203
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C. Maintenance <br />9 <br />Note: Strict programming of the control electronics oj all San-I-Pak units prevents the discharge of <br />unslerilized waste. San-l-Pak employs parametric motoring, which is superior to Biological Tests. <br />The computer has a built-in steam table that enables constant comparison of vessel temperature with <br />vessel pressure. Other fail-safes such as time to vacuum, vacuum level, time to temperature, droop <br />control and vent time exceed conventional testing. In the unusual occurrence of any discrepancy in <br />the programmed parameters, the process will be halted and then after correction cycle must be <br />restarted. <br />Maintenance of the autoclaves is performed consistent with the autoclave manufacturer’s <br />recommendations, which include the following schedule of maintenance activities and planned <br />frequency. <br />1710 Incubator -Getinge model <br />Dox Matrix Printer-Model-CBM-9IO-Type 11 <br />Serial Number-SW20127000 <br />The biological ampoule contained within the AccuFast Biological Test Pack, which Includes a paper <br />strip containing G. stearothermophilus inside an ampoule of specially formulated growth medium, <br />should be incubated at approximately 60°C. for 10 hours. After incubation, the ampoule visually <br />indicates growth or no growth of the indicator spore. No color change (any growth) equals complete <br />sterilization. Sterilization failure is noted by positive growth of the bacteria which turns the medium <br />color from purple (PASS) to yellow (FAIL). <br />color change is not a true confirmation of fail or pass as the incubator visual change is the true <br />indication of pass and fail for each load. <br />Controls H
The URL can be used to link to this page
Your browser does not support the video tag.