Laserfiche WebLink
Non-Water Release Corrective Action Plan <br />North County Recycling Center and Sanitary Landfill <br />AU24.1294.00 | Non-Water Release Corrective Action Plan Update 12 <br />October 2024 <br />• The presence of carbon monoxide (CO) in the gas collected by the landfill gas collection <br />system at levels that exceed 1,000 parts per million (ppm) <br />• Substantial settlement over a short period of time <br />• Smoke emanating from the gas extraction system or landfill <br />• Combustion residue in landfill gas extraction wells and/or headers <br />• Increase in gas temperature in the extraction system (above 140° Fahrenheit) <br />• Temperatures in excess of 170° Fahrenheit in the waste <br />Note that the County measures the concentration of CO at each well using portable detection <br />equipment on a monthly basis. <br />CalRecycle consider levels of CO in excess of 1,000 ppm to be a positive indication of an active <br />underground landfill fire. Levels of CO between 100 and 1,000 ppm are viewed as suspicious <br />and require further air and temperature monitoring. Levels between 10 and 100 ppm may be <br />an indication of a fire but active combustion is not present. To date, CO has not been detected <br />at the NCRCSL over 100 ppm at any well. <br />Due to the landfill gas extraction systems at the NCRCSL, subsurface fires are considered a <br />reasonably foreseeable casual event and therefore mitigation measures were evaluated as part <br />of this NWRCAP. <br />4.3.2 Wildfires <br />Wildfires have been documented to destroy or damage landfill monitoring systems, vegetation, <br />and irrigation systems. The potential damage to a landfill caused by wildfires can vary <br />significantly depending on the facility location, surrounding terrain, local weather conditions, <br />and protective measures (such as fire breaks). <br />CalRecycle’s BMP guidelines recognize the Department of Forestry and Fire Protection (Cal Fire) <br />and local fire agencies for potential fire hazards. Landfills located within or adjacent to <br />moderate/medium or high/very high fire hazard zones should be evaluated for potential <br />damage due to wildfire. Based on a current review of Cal Fire’s Fire Hazard Severity Zone map <br />for San Joaquin County, there have been no updates to the map. The current map shows that <br />the NCRCSL falls under the responsibility of the local fire jurisdiction (see Figure 4) and is within <br />an un-zoned area of fire hazard severity. Also, the landfill is surrounded by irrigated agricultural <br />land and fuel for a wildlands fire is minimal. <br />Due to the location of the NCRCSL, and designation of un-zoned fire hazard severity, wildfires <br />are not considered a reasonably foreseeable causal event for this facility. <br />4.4 Flooding Impacts <br />CalRecycle’s BMPs require evaluation of the landfill in relation to the 500-year flood zone,