PUE Program Standards Compendium Volume 3 <br /> Restricted Materials and Permitting <br /> Guidance for 9,3-D Enforcement, Continued <br /> Example If Blocks 1 and 2 overlap,for both blocks the setback distance from <br /> setbacks for occupied structures is 500 ft,determined from: <br /> overlapping - 15 acres from Block 1 +Block 2 combined <br /> applications, - 332 lbs./ac from Block 2,higher than Block 1 <br /> (continued) - Setback from Table 3a,Field Fumigation Requirements document <br /> (Block 1),larger than Table 5b,Field Fumigation Requirements <br /> document(Block 2) <br /> If all overlapping application blocks use the same fumigation method and the <br /> same application rate,such as when a large field is broken up and fumigated <br /> sequentially over several days,the setback distance is determined using the <br /> combined acreage. <br /> If an NOI for a 1,3-D application scheduled for a later date overlaps with a <br /> previous application,the NOI must be denied if the combined acreage <br /> exceeds the distance specified by the setback table or the earlier application <br /> cannot accommodate the changes caused by the later application(i.e.,the <br /> combined acreage cannot comply with the setback distance and maximum <br /> acreage specified by the setback table). <br /> Continued on next page <br /> J-11 <br /> Appendix J—1,3-Dichloropropene(Field Soil Fumigation) <br /> Recommended Permit Conditions and Enforcement Guidance(10-07-2025) <br />