My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601204
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCUST TREE
>
14400
>
2600 - Land Use Program
>
SU-2601204
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/1/2026 9:17:51 AM
Creation date
5/6/2026 12:00:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU-2601204
PE
2625 - CONDITIONAL USE MINOR (C)
STREET_NUMBER
14400
Direction
N
STREET_NAME
LOCUST TREE
STREET_TYPE
RD
City
LODI
Zip
95240
APN
06315016
CURRENT_STATUS
Closed - Issued
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
N RD LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SPECIFICATIONS <br /> REVISIONS ° <br /> SYSTEM SIZE DC 4,824.06 kW 15 PRELIM LAYOUT 08/29/26 0 <br /> 0 <br /> E KETTLEMAN LN SYSTEM SIZE AC 4,000.00 kW N <br /> 16 PRELIM LAYOUT 09/19/26 <br /> A <br /> DC/AC RATIO 1.21 I <br /> 0 <br /> # MODULE MANUFACTURER FIRST SOLAR } <br /> MODULE MODEL FS-7530A-TR1 0 <br /> MODULE RATING 530 W 0 <br /> O <br /> TOTAL MODULE QTY 9,102 <br /> MODULES PER STRING 6 <br /> Y TOTAL NO. OF STRINGS 1,517 <br /> INVERTER MODEL CPS SCH250K-T-US-600 <br /> INVERTER RATING 250 kW W to <br /> INVERTER QTY — 16 mi ui <br /> STEP-UP TRANSFORMER (2)2.2MVA, 21 KV/600V M <br /> RACKING ATI HSAT In <br /> RACKING <br /> ' <br /> 16.0 #84 MODULE TRACKER 61 <br /> I W o <br /> #66 MODULE TRACKER 38 r <br /> ACCESS B #42 MODULE TRACKER 35 W w o <br /> TILT ANGLE 0° z 0 L qp <br /> INTER-ROW SPACING 9.22' W N v w a <br /> PITCH 16.77' 1r <br /> IEEE <br /> � 0cow <br /> GCR 45% Lu cU n <br /> SITE AREA INSIDE FENCE 18.51 Ac ���� 0 Z M Z <br /> m■■L �- a !-Lu <br /> ,•�` 0 z 0 3: <br /> LEGEND cn 5- <br /> ATI <br /> ATI 84 MODULE TRACKER o cO � o <br /> � 4 U <br /> LLJ <br /> ATI 66 MODULE TRACKER <br /> POI COORDINATES: 38.112687°, -121.189649° Cf) v 0 <br /> FEEDER NAME: LOCKEFORD 2101 <br /> ATI 42 MODULE TRACKER � w N C <br /> w � q) <br /> POWER STATION - (1) MV TRANSFORMER, (1) DAS, > " <br /> POLE-0 o _j .c) <br /> (1)WEATHER STATION [If w O <br /> UTILITY SCADA RECLOSER c� <br /> STRING INVERTER Q J <br /> POLE-1 — o < <br /> UTILITY REVENUE METER16' WIDE SITE ACCESS ROAD N <br /> POINT OF COMMON COUPLING (PCC) <br /> N <br /> WELL COORDINATES: 38.112500°,-121.188472° (E) PUBLIC ROAD <br /> POLE15.0' PROPERTY THE EXACT LOCATION WILL BE CONFIRMED BY ;4 0 <br /> CUSTOMER RECLOSER OVE BOUNDARY TO FENCE SITE SURVEY TBD PROPERTY LINE z LL <br /> OVE c#0Q Ll W Z Q <br /> RISER WITH AC DISCONNECT SWITCH — — — °VE OVEN �� PROJECT SITE SECURITY FENCE o cn cn <br /> °�E <br /> � _ 0 <br /> 30.0'PROPERTY w z w cn <br /> BOUNDARY TO MODULECo Q <br /> SETBACK <br /> PROJECT <br /> (E) OH LINES <br /> / o <br /> / \\ Mv Mv MV CABLE <br /> / \ EXISTING STRUCTURE <br /> 50.0'SETBACK FROM / \ °m Q <br /> OVERHEAD LINE g \ VEGETATION BUFFER J <br /> / \\ 0 WELL O <br /> cl) <br /> o��` � — m <br /> SII <br /> GENERAL NOTESco <br /> Z ti M <br /> \ 1. REFER TO SINGLE LINE DIAGRAM FOR DETAILS. W <br /> o co <br /> W <br /> I 2. INSTALLATION TO COMPLY WITH NEC 2023 ARTICLE 690 AND ALL APPLICABLE Z r <br /> 16.0' I / LOCAL, STATE AND NATIONAL CODES OR REGULATIONS. r <br /> 0 Y L 3. EQUIPMENT SHALL BE LABELED PER NEC 690 AND UTILITY REGULATIONS. 0Lu Ll r <br /> HUJI M N <br /> \ /100.0' SETBACK <br /> 4. 16'ACCESS ROADS SHALL BE DESIGNED TO ACCOMMODATE ALL Q <br /> CONSTRUCTION, OPERATIONS, MAINTENANCE, AND UTILITY TRAFFIC J 1 <br /> FROM THROUGHOUT THE SITE. <br /> N <br /> U EXISTING STRUCTURE ■, Lo <br /> 5. DIMENSIONS TO PROPERTY LINES AND EXISTING FEATURES ARE . . <br /> � b APPROXIMATE PENDING SURVEY. O W M z <br /> z <br /> 6. THIS DRAWING REPRESENTS A CONCEPTUAL INTERCONNECTION SCHEME. J Q <br /> r THE INTENT IS TO COMMUNICATE PROJECT SPECIFIC EQUIPMENT, SIZE ANDJ J J <br /> NEGOTIATE THE INTERCONNECTION DETAILS WITH THE UTILITY. THIS z Lu <br /> PARCEL APN :06315016 DRAWING HAS NOT BEEN ISSUED FOR CONSTRUCTION PURPOSES. THE <br /> DEVELOPER OR CONTRACTOR IS RESPONSIBLE FOR ENSURING A SYSTEM SHEET TITLE <br /> II 10.0' 10.0'VEGETATION BUFFER DESIGN IS COMPLETE AND APPROVED BY AN APPROPRIATELY LICENSED <br /> ENGINEER PRIOR TO PROCUREMENT AND CONSTRUCTION. <br /> ACCESS A <br /> I <br /> _ - PERMIT SET <br /> 16.8' <br /> 16.0' <br /> 30.0' SETBACK FROM <br /> PROPERTY LINE <br /> SCALE: AS SHOWN <br /> DRAWN:LR <br /> DATE: 09/19/26 <br /> ARRAY LOCATION <br /> PV-100PV- 10 0 <br /> SCALE.1 -150 NOT FOR CONSTRUCTION , FOR IA DISCUSSION ONLY . <br /> SHEET 1 OF 2 <br /> THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY QE SEQUOIA ENGINEERING AND DESIGN ASSOCIATES AND MAY NOT BE USED OR REPRODUCED WITHOUT WRITTEN PERMISSION. <br />
The URL can be used to link to this page
Your browser does not support the video tag.