Laserfiche WebLink
REVISIONS <br /> 0 <br /> w <br /> 15 PRELIM LAYOUT 08/29/26 0 <br /> 0 <br /> 16 PRELIM LAYOUT 09/19/26 1 <br /> SYSTEM SPECIFICATIONS I <br /> c� <br /> SYSTEM SIZE DC 4,824.06 kW <br /> SYSTEM SIZE AC 4,000.00 kW POI o <br /> (E) POLE u <br /> DC/AC RATIO 1 .21 POI COORDINATES TO PG&E 21 KV <br /> MODULE MANUFACTURER FIRST SOLAR 38.112687°, -121.189649° FEEDER NAME: LOCKEFORD 2101 <br /> MODULE MODEL ES-7530A-TRI <br /> MODULE RATING 530 W -67' EEG END : <br /> TOTAL MODULE QTY 9,102 POLE 0 <br /> Wto <br /> MODULES PER STRING 6 <br /> TRANSFORMER mi W <br /> TOTAL No. OF STRINGS 1517 UTILITY 52R UTILITY m <br /> INVERTER MODEL CPS SCH250K-T-US-600 RECLOSER COMM. co <br /> INVERTER RATING 250 kW OH MV SPAN 30, 3W POTENTIAL TRANSFORMER W c <br /> INVERTER QTY 16 _ PCC UTILITY W a <br /> STEP-UP TRANSFORMER �(2)2.2MVA, 21 KV/600V POLE 1 CUSTOMER CURRENT TRANSFORMER O w <br /> CONNECTIONS AT TOP OF POLE 1 o w w 0 <br /> W � � agq <br /> UTILITY INFORMATION UTILITY p Q- U to <br /> O <br /> METER UTILITY COMM. Lu Lu U} GROUND, GND Lu O T- a <br /> UTILITY PG&E MO � <br /> INTERCONNECT VOLTAGE 21 kV A a SURGE ARRESTOR a vw <br /> PLANT SCADA } ANN ui 0 Z M Z <br /> M1 z C7 �mN Z lww <br /> MCOV Il ISO COMM. Z ,•:` Q <br /> M2 u� g 0 POLE FOR OVERHEAD LINE <br /> POLE Cl — a I* cA a <br /> Q 0 52R RECLOSER <br /> MCOV I Q U o m 00 o <br /> U <br /> QFUSE [-- 6' <br /> CUSTOMER U =) Q <br /> cn v 0 <br /> RECLOSER 52R / 27 59 59G 810 81U XXXXA, XP <br /> w N <br /> M-7679 R-PAC w w 6' <br /> (NOTE 10) o- BREAKER o u J ID <br /> � w 'o <br /> 50 51 51G — z ~ C <br /> INVERTER O <br /> Ln <br /> POLE C2 — N <br /> N <br /> UTILITY ACCESSIBLE WITH LOCK <br /> DISCONNECT MCOV PROVISION AND VISIBLE BLADE INVERTERS <br /> AND RISER INERTIA LINEBOSS OAE O DISCONNECTING SWITCH <br /> z Li <br /> Li <br /> OVERHEAD LINE V) o w z <br /> UG MV CABLE 30, 4W D z 0 o <br /> o cn cn <br /> cn <br /> UNDERGROUND LINE w z w <br /> caw®Q <br /> (N) PV SWITCHGEAR #1 COMMUNICATION LINE PROJECT <br /> 2500A, 600V, 3�, 4W, NEMA3R, <br /> INV-01 MAIN BREAKER W/ O ANSI DEVICE NUMBER <br /> 250KW 600V METERING SECTION <br /> (TYP. OF 8) <br /> -- -- -- — XFMR 1 <br /> . . AC �I 60OV/21kV TRANSFORMER <br /> BREAKER 350A, 3P 2200KVA PV MODULE <br /> w/ FUSE/DISCONNECT j <br /> FROM OTHER Z=7%, X/R=11.5 O <br /> SOURCE CIRCUITS �/� <br /> 350A, 3P V <br /> — ANTI-PID: ON� /� Al I Y CURRENT WEAK <br /> -- -- - -- -- 2500A, 3P <br /> PLANT (�" LIMITING LINE O O <br /> SCADA ■' co <br /> FROM ALL OTHER 0 350A, 3P LOAD Z M <br /> INVERTERS • �� BREAK W a) <br /> �0 GFP Lu O co <br /> I i II NOTES : <br /> � Z � 00 <br /> 40A, 3P <br /> TO 120/240/480V AUX <br /> PANELS FOR (� <br /> SCADA, TELECOM, 1. AC MV CIRCUITS SHALL BE INSTALLED AND INTERCONNECTED WITH <br /> TRACKERS — UTILITY, PER UTILITY SPECIFICATIONS. uj Q M <br /> cn J <br /> 2. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE LATEST AHJ N <br /> APPROVED EDITION OF NATIONAL ELECTRIC CODE. <br /> (N) PV SWITCHGEAR #2 ., Lo <br /> 2500A, 600V, 3�, 4W, NEMA3R, ■ ■ ■ ■ <br /> INV-09 3. ALL DC AND AC EQUIPMENT, WHERE APPLICABLE, SHALL BE LISTED AND W 0 <br /> 250KW 600V MAIN BREAKER W/ LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AND J <br /> (TYP. OF 8) METERING SECTION INSTALLED PER THE LISTING REQUIREMENTS, THE MANUFACTURER'S O Q Q O <br /> __ __ _ _ _ _ _'l IIlk XFMR 2 INSTRUCTIONS & IN ACCORDANCE WITH NEC. Z W J U J J <br /> BREAKER 350A 3P �I 60OV/21kV TRANSFORMER 4. RECLOSER CONTROL SETTINGS TO BE COORDINATED WITH UTILITY AND. . . N <br /> w/ FUSE/DISCONNECT CONTRACTOR. SHEET TITLE <br /> FROM OTHER I 7� q� 7- I � I Z=7%, X/R=11.5 <br /> 5. RELAY TO BE PROVIDED WITH 8-HOUR BATTERY BACK-UP. <br /> SOURCE CIRCUITS I 350A, 3P I <br /> 6. UTILITY RIG, METER, WEATHER STATION AND ASSOCIATED <br /> -- -- -- - -- /"-� 2500A, 3P I Y 0 CURRENT WEAK COMMUNICATIONS EQUIPMENT TO BE PROVIDED WITH BATTERY BACK-UP <br /> PLANT 0 O-Alo LIMITING LINE PER UTILITY REQUIREMENTS. <br /> � � I I I I <br /> SCADA FROM ALL OTHER 0 7. ALL BREAKERS AND DISCONNECT SWITCHES ARE CLOSED UNDER NORMAL <br /> INVERTERS 350�� LOAD SINGLE LINE <br /> BREAK — —� OPERATING CONDITIONS UNLESS OTHERWISE NOTED. <br /> �0 GFP <br /> 8. THIS DRAWING REPRESENTS A CONCEPTUAL INTERCONNECTION SCHEME. <br /> DIAGRAM <br /> TO 120/240/480V AUX 40A, 3P THE INTENT IS TO COMMUNICATE PROJECT SPECIFIC EQUIPMENT, SIZE <br /> �� AND NEGOTIATE THE INTERCONNECTION DETAILS WITH THE UTILITY. THIS <br /> PANELS FOR DRAWING HAS NOT BEEN ISSUED FOR CONSTRUCTION PURPOSES. THE <br /> SCADA, TELECOM, <br /> TRACKERS DEVELOPER OR CONTRACTOR IS RESPONSIBLE FOR ENSURING A SYSTEM <br /> � -- -- -� -- -- -� <br /> DESIGN IS COMPLETE AND APPROVED BY AN APPROPRIATELY LICENSED <br /> ENGINEER PRIOR TO PROCUREMENT AND CONSTRUCTION. <br /> 9. INVERTERS ARE IEEE 1547 COMPLIANT AND UL 1741 SA LISTED SCALE: AS SHOWN <br /> 10. RECOMMENDED RECLOSER: G&W VIPER DRAWN:LR <br /> RECOMMENDED CONTROLLER: BECKWITH M-7679.R-PAC DATE: 09/19/26 <br /> � SINGLE LINE DIAGRAM <br /> CONSTRUCTION , E- 101 <br /> E-101 NOTFOR FOR IA DISCUSSION ONLY . <br /> SHEET 2 OF 2 <br /> THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF SEQUOIA ENGINEERING AND DESIGN ASSOCIATES AND MAY NOT BE USED OR REPRODUCED WITHOUT WRITTEN PERMISSION. <br />