My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601204
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCUST TREE
>
14400
>
2600 - Land Use Program
>
SU-2601204
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2026 7:44:27 AM
Creation date
5/6/2026 12:00:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU-2601204
PE
2625 - CONDITIONAL USE MINOR (C)
STREET_NUMBER
14400
Direction
N
STREET_NAME
LOCUST TREE
STREET_TYPE
RD
City
LODI
Zip
95240
APN
06315016
CURRENT_STATUS
Closed - Issued
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
14400 N LOCUST TREE RD LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SPECIFICATIONS <br /> REVISIONS ° <br /> SYSTEM SIZE DC 4,824.06 kW 10 PRELIM LAYOUT 04/09/26 0 <br /> 0 <br /> E KETTLEMAN LN SYSTEM SIZE AC 4,000.00 kW MMM� Ag <br /> PRELIM LAYOUT 12/19/25 <br /> DC/AC RATIO 1 .21 z <br /> MODULE MANUFACTURER FIRST SOLAR <br /> MODULE MODEL FS-7530A-TR1 0 <br /> MODULE RATING 530 W 0 <br /> O <br /> TOTAL MODULE QTY 9,102 <br /> MODULES PER STRING 6 <br /> TOTAL NO. OF STRINGS 1517 <br /> INVERTER MODEL CPS SCH350KTLDO/US-800 <br /> INVERTER RATING 350 kW 325 kW* W to <br /> INVERTER QTY 4 8 <br /> STEP-UP TRANSFORMER (2)2.2MVA, 21 KV/800V I W <br /> RACKING ATI HSAT <br /> # 84 MODULE TRACKER 61 <br /> � W o <br /> # 66 MODULE TRACKER 38CLr <br /> # 42 MODULE TRACKER 35 W � o <br /> TILT ANGLE 0° Z O w I <br /> INTER-ROW SPACING 9.2' W N v a <br /> PITCH 16.8' � 0 � 0 <br /> OCR 45% w c) 'r- a <br /> 2Lon3� <br /> SITE AREA INSIDE FENCE 18.51 Ac ANNA S Z M Z <br /> *INVERTER OUTPUT POWER SHALL BE FACTORY-SET WITH A MAXIMUM NET Moot z W w 1Lu <br /> 3� <br /> OUTPUT LIMIT OF 325 KW ,•0-` 0 z O 3: <br /> '4vaia � <br /> LEGEND <br /> - - 0cOr) E <br /> 0 m 0 0 <br /> � Ln U <br /> ATI 84 MODULE TRACKER L � <br /> IEPOI <br /> COORDINATES: 38.112687', -121 .189649' Cf) v o <br /> FEEDER NAME: LOCKEFORD 2101 ATI 66 MODULE TRACKER <br /> � � � � <br /> I [If w N C <br /> ATI 42 MODULE TRACKER > LLJ M <br /> v <br /> UTILITY SCADA RECLOSER FITPOWER STATION - (1 ) MV TRANSFORMER, � L�J .o <br /> (1 ) DAS, (1 ) WEATHER STATION z <br /> QQ <br /> POLE-1 _pw STRING INVERTER 7mi 3 <br /> = UTILITY REVENUE METER N <br /> POINT OF COMMON COUPLIING (PCC) N <br /> 12' WIDE SITE ACCESS GRAVEL ROAD <br /> POLE-C1 WELL COORDINATES: 38.112500°,-121 .188472° <br /> 15.0'PROPERTY THE EXACT LOCATION WILL BE CONFIRMED BY (E) PUBLIC ROAD c� <br /> CUSTOMER RECLOSER BOUNDARY TO FENCE SITE SURVEY TBD z w <br /> OVE E <br /> POLE-C2 OVEVE PROPERTY LINE o w z u <br /> z0 <br /> RISER WITH AC DISCONNECT SWITCH - - - OVE OVE OVE—�� c#0 o 5 � C/5- - - _ 30.O'PROPERTY v PROJECT SITE SECURITY FENCE c�woQ <br /> / F - BOUNDARY TO MODULE - - <br /> SETBACK PROJECT <br /> OVE (E) OH LINES <br /> / IJ \ - Mv My- MV CABLE <br /> i 10.0' VEGETATION �+ <br /> 50.0'SETBACK FROM / I� BUFFER °m EXISTING STRUCTURE Q <br /> I <br /> OVERHEAD LINE � I,,�� <br /> _ VEGETATION BUFFER J <br /> O <br /> / oo< x ° O WELL co <br /> m <br /> � � O G <br /> C� <br /> I I � � OC o0 <br /> GENERAL NOTES W J �� <br /> Lo <br /> > 1 . REFER TO SINGLE LINE DIAGRAM FOR DETAILS. W co <br /> g <br /> Z Oo <br /> 12.0' / 2. NSTALLATION TO COMPLY WITH NEC 2023 ARTICLE 690 AND ALL Q r r <br /> V APPLICABLE LOCAL, STATE AND NATIONAL CODES OR REGULATIONS. <br /> 0 r <br /> w M 3. EQUIPMENT SHALL BE LABELED PER NEC 690 AND UTILITY W M N <br /> REGULATIONS. <br /> (n J Q r <br /> u100.0' SETBACK FROM 4. 12' ACCESS ROADS SHALL BE DESIGNED TO ACCOMMODATE ALL N <br /> EXISTING STRUCTURE CONSTRUCTION, OPERATIONS, MAINTENANCE, AND UTILITY TRAFFIC !, Lo <br /> o x THROUGHOUT THE SITE. W . . <br /> O Fm Z <br /> z5. DIMENSIONS TO PROPERTY LINES AND EXISTING FEATURES ARE J <br /> APPROXIMATE PENDING SURVEY. O Q O <br /> I ZWJ0JJ <br /> 6, THIS DRAWING REPRESENTS A CONCEPTUAL INTERCONNECTION SCHEME. <br /> PARCEL APN :06315016 1 THE INTENT IS TO COMMUNICATE PROJECT SPECIFIC EQUIPMENT, SIZE <br /> 17 I>ol AND NEGOTIATE THE INTERCONNECTION DETAILS WITH THE UTILITY. THIS SHEET TITLE <br /> oo DRAWING HAS NOT BEEN ISSUED FOR CONSTRUCTION PURPOSES. THE <br /> DEVELOPER OR CONTRACTOR IS RESPONSIBLE FOR ENSURING A <br /> L LJ SYSTEM DESIGN IS COMPLETE AND APPROVED BY AN APPROPRIATELY <br /> oo LICENSED ENGINEER PRIOR TO PROCUREMENT AND CONSTRUCTION. <br /> I <br /> PERM T SET <br /> = J 9.2` 16.8' <br /> 30.0' SETBACK FROM <br /> PROPERTY LINE <br /> SCALE: AS SHOWN <br /> -— DRAWN:LR <br /> DATE: 04/09/26 <br /> ARRAY EOCAT OR N <br /> 99NOT PV - 100 <br /> scA�E � � S � 0O O O � C � � 0 0 `� o <br /> SHEET 1 OF 2 <br /> THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF SEQUOIA ENGINEERING AND DESIGN ASSOCIATES AND MAY NOT BE USED OR REPRODUCED WITHOUT WRITTEN PERMISSION. <br />
The URL can be used to link to this page
Your browser does not support the video tag.