Laserfiche WebLink
REVISIONS <br /> 0 <br /> W <br /> 0 <br /> 10 PRELIM LAYOUT 04/09/26 No <br /> 0 <br /> SYSTEM SPECIFICATIONS ZL <br /> PRELIM LAYOUT 12/19/25 <br /> z <br /> c� <br /> SYSTEM SIZE DC 4,824.06 kW a <br /> SYSTEM SIZE AC 4,000.00 kW (E) PPP 0 <br /> OLE � <br /> DC/AC RATIO 1 .21 POI COORDINATES TO PG&E 21 KV <br /> MODULE MANUFACTURER FIRST SOLAR 38.112687°, -121 .189649° FEEDER NAME: LOCKEFORD 2101 <br /> MODULE MODEL FS 753OA-TRI I <br /> MODULE RATING 530 W N67 EEG END : <br /> TOTAL MODULE QTY 9,102 POLE 0 <br /> to <br /> MODULES PER STRING 6 W <br /> TRANSFORMER J W <br /> TOTAL NO. OF STRINGS 1517 UTILITY 52R UTILITY comm. co <br /> INVERTER MODEL CPS SCH350KTL-DO/US-800 RECLOSER <br /> INVERTER RATING 350 kW 325 kW* OH MV SPAN 30, 3W POTENTIAL TRANSFORMER W c <br /> Lo <br /> INVERTER QTY 4 8 <br /> PCC UTILITYW a `"� <br /> STEP-UP TRANSFORMER (2)2.2MVA, 21 KV/800V POLE 1 - c CURRENT TRANSFORMER c <br /> CONNECTIONS AT TOP OF POLE 1 CUSTOMER Q w Z w O <br /> *INVERTER OUTPUT POWER SHALL BE FACTORY-SET WITH A MAXIMUM v� > W °Lu �'O <br /> LLJ <br /> NET OUTPUT LIMIT OF 325 KW UTILITY \ o Q` co v to p <br /> rn <br /> METER w Q GROUND, GND w 0 00 a <br /> UTILITY INFORMATION MO TIL Y C MM. Q �., O U LU <br /> M z <br /> UTILITY PG&E M1 LA S DA z CD SURGE ARRESTOR 'NNS Q vw <br /> mmm <br /> Oz ���� ZOLLz � <br /> INTERCONNECT VOLTAGE 21 kV Q <br /> MCOV z 0 <br /> M2 0 OM U Q 0 POLE FOR OVERHEAD LINE � � <br /> POLE Cl - D le cai) a <br /> MCOV Q ou 52R RECLOSER <br /> 0 0o ro H <br /> O m 00 C) <br /> Q Lo U <br /> Q U) Li <br /> Li <br /> CUSTOMER <cr) 00 <br /> a <br /> RECLOSER 52R 27 59 59G 810 81U XXXXA, XP <br /> _ �'C <br /> W N <br /> M-7679 R-PAC BREAKER > <br /> (NOTE 1 0) o u J .D <br /> � wCD <br /> o <br /> 50 51 51G _ z ~ 10 <br /> INVERTER <br /> POLE C2 N <br /> N <br /> UTILITY ACCESSIBLE WITH LOCK <br /> DISCONNECT MCOV I PROVISION AND VISIBLE BLADE INVERTERS <br /> AND RISER INERTIA LINEBOSS OAE O DISCONNECTING SWITCH cn <br /> z w <br /> OVERHEAD LINE o w z 0 <br /> UG MV CABLE 30, 4W z 0 o <br /> o c� cn cn <br /> UNDERGROUND LINE w z w �' <br /> c�wDQ <br /> (N) PV SWITCHGEAR #1 COMMUNICATION LINE PROJECT <br /> 2000A, 800V, 3�, 4W, NEMA3R, <br /> 350/325KW 800v <br /> INV- MAIN BREAKER W/ 0 ANSI DEVICE NUMBER <br /> (TY P. OF 6) METERING SECTION <br /> XFMR 1 <br /> ... AC 80OV/21kV TRANSFORMER <br /> BREAKER 350A, 3P 2200KVA PV MODULE <br /> w/ FUSE/DISCONNECT J <br /> FROM OTHER Z=7�, X/R=11.5 O <br /> SOURCE CIRCUITS (n <br /> 350A, 3P <br /> 2000A, 3P Y CURRENT WEAK <br /> PLANT LIMITING LINE (D co <br /> SCADA <br /> FROM ALL OTHER 0 350A, 3P LOAD <br /> I` M <br /> INVERTERS • BREAK W J a) Lo <br /> �OGFP W/ O co <br /> 00 <br /> 40A, 3P NOTES - <br /> TO o .+ Z <br /> 120/240/480V AUX Q <br /> PANELS FOR <br /> SCADA, TELECOM, 1 . AC MV CIRCUITS SHALL BE INSTALLED AND INTERCONNECTED WITH M N <br /> TRACKERS <br /> UTILITY, PER UTILITY SPECIFICATIONS. W <br /> � J <br /> 2. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE LATEST N <br /> (N) PV SWITCHGEAR #2 AHJ APPROVED EDITION OF NATIONAL ELECTRIC CODE. Lf) <br /> 2000A, 800V, 3 , 4W, NEMA3R, ■ ■ <br /> INV-01 � 3. ALL DC AND AC EQUIPMENT, WHERE APPLICABLE, SHALL BE LISTED O W Q � Z <br /> 350/325KW 800V MAIN BREAKER W/ AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY J <br /> METERING SECTION AND INSTALLED PER THE LISTING REQUIREMENTS, THE O Q Q O <br /> (TYP. OF 6) XFMR 2 MANUFACTURER'S INSTRUCTIONS & IN ACCORDANCE WITH NEC. Z W J U J J <br /> , . , AC 80OV/21 kV TRANSFORMER 4. RECLOSER CONTROL SETTINGS TO BE COORDINATED WITH UTILITY <br /> BREAKER350�, 3P w/ FUSE/DISCONNECT <br /> AND CONTRACTOR. SHEET TITLE <br /> FROM OTHER Z=7%, X/R=11.5 5. RELAY TO BE PROVIDED WITH 8-HOUR BATTERY BACK-UP. <br /> SOURCE CIRCUITS <br /> 350A, 3P 6. UTILITY RIG, METER, WEATHER STATION AND ASSOCIATED <br /> �� 2000AO-All , 3P Y CURRENT WEAK COMMUNICATIONS EQUIPMENT TO BE PROVIDED WITH BATTERY <br /> PLANT ( LIMITING LINE BACK-UP PER UTILITY REQUIREMENTS. G <br /> SCADA � I �I �7 E R R <br /> FROM ALL OTHER � 350A, 3P LOAD � 7. ALL BREAKERS AND DISCONNECT SWITCHES ARE CLOSED UNDER D A� RAM <br /> INVERTERS BREAK NORMAL OPERATING CONDITIONS UNLESS OTHERWISE NOTED. <br /> 0o��O-AOG FP <br /> 8. THIS DRAWING REPRESENTS A CONCEPTUAL INTERCONNECTION <br /> AUX 40A, 3P SCHEME. THE INTENT IS TO COMMUNICATE PROJECT SPECIFIC <br /> TO 120/240/480V <br /> EQUIPMENT, SIZE AND NEGOTIATE THE INTERCONNECTION DETAILS <br /> PANELS FOR WITH THE UTILITY. THIS DRAWING HAS NOT BEEN ISSUED FOR <br /> SCADA, TELECOM, CONSTRUCTION PURPOSES. THE DEVELOPER OR CONTRACTOR IS <br /> TRACKERS RESPONSIBLE FOR ENSURING A SYSTEM DESIGN IS COMPLETE AND <br /> APPROVED BY AN APPROPRIATELY LICENSED ENGINEER PRIOR TO <br /> PROCUREMENT AND CONSTRUCTION. <br /> SCALE: AS SHOWN <br /> 9. INVERTERS ARE IEEE 1547 COMPLIANT AND UL 1741 SA LISTED <br /> DRAWN:LR <br /> DATE: 04/09/26 <br /> � S RDD D RD D ARAM <br /> NOT DOD CONSTRUCT0N , DOD O D SCUSS0 0 Yo E 100 <br /> SHEET 2 OF 2 <br /> THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF SEQUOIA ENGINEERING AND DESIGN ASSOCIATES AND MAY NOT BE USED OR REPRODUCED WITHOUT WRITTEN PERMISSION. <br />