Laserfiche WebLink
SAN JOAQUIN Environmental Health Department <br /> —COUNTY <br /> CP26 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> NORCAL FUELS 13300 N WEST LN, STOCKTON July 13, 2026 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 4 23 CCR 16 2613(a)(4) and (b), 2650(a), (c), and (e) 2011012 - Facility has submitted and maintains a monitoring site <br /> plan <br /> OBSERVATION: Owner/Operator failed to submit and maintain a monitoring site plan for approval by the UPA. The <br /> monitoring site plan was: <br /> - not scaled <br /> REGULATION GUIDANCE: § 2650(c) Monitoring Site Plan —Owners or operators must submit a monitoring site plan for <br /> approval by the Unified Program Agency. The monitoring site plan must include, but is not limited to, the following: (1)A <br /> scaled diagram indicating the layout of the tank(s) and piping to the extent known, including containment sumps; (2) <br /> Locations of all release detection equipment; and (3) If applicable, each vacuum, pressure, or hydrostatic interstitial <br /> monitoring zone. <br /> CORRECTIVE ACTION: Submit and maintain a monitoring site plan. <br /> This is a (Minor)Violation. <br /> 5 23 CCR 16 2613(a)(6) and (b), 2650(a), (d), and (e) 2011013 - Facility has submitted a complete and accurate UST <br /> Response Plan <br /> OBSERVATION: Owner/Operator failed to submit a complete and accurate UST Response Plan. The UST Response <br /> Plan submitted in CERS does not have emergency contact information listed for Responsible Persons or a 24 hour <br /> phone number for a continuously staffed emergency operations center. <br /> REGULATION GUIDANCE: § 2650(d) Response Plan —Owners or operators must submit a response plan to the Unified <br /> Program Agency which demonstrates, to the satisfaction of the Unified Program Agency, that any unauthorized release <br /> will be removed from the secondary containment as soon as practical. This must be within a time consistent with the <br /> ability of the secondary containment to contain the hazardous substance but must not exceed 30 days. The response <br /> plan must include, but is not limited to, the following: (2) For methods of monitoring where the presence of the hazardous <br /> substance in the interstitial space cannot be determined directly, for example, where liquid level measurements are used <br /> as the basis for determination, the response plan must specify the proposed method(s)for determining the presence or <br /> absence of the hazardous substance if the indirect method indicates a possible unauthorized release of hazardous <br /> substance. <br /> CORRECTIVE ACTION: Submit a complete and accurate UST Response Plan. <br /> This is a Repeat(Class 2)Violation. <br /> 6 23 CCR 16 2613(a)(7) and (b), 2690(a)(5); HSC 6.7 25292.2 2011008-Submitted/maintained current Cert of Financial <br /> Responsibility/mech of financial assurance (TCR 11) <br /> OBSERVATION: Owner/Operator failed to submit and/or maintain a complete and current Certification of Financial <br /> Responsibility or other mechanism of financial assurance. The financial responsiblity documents in CERS and on site are <br /> outdated. The Certification of Financial Responsiblity and Letter from Chief Financial Officer Letter are dated 7/31/2024. <br /> REGULATION GUIDANCE: § 2613 (a)(7) Certification of Financial Responsibility in accordance with section 2809.1§ <br /> 2809.1 (a) Owners and operators must maintain evidence of all mechanisms used to demonstrate financial responsibility <br /> in accordance with the provisions of this article until the provisions of this article no longer require such maintenance. <br /> Such evidence must be maintained at the underground storage tank site or sites or the owner or operator's place of <br /> business. <br /> CORRECTIVE ACTION: Submit a complete and current Certification of Financial Responsibility, or other mechanism of <br /> financial assurance within 30 days. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 4 of 6 FA0003847 PR0231289 4672832 7/13/2026 <br /> CP26-UST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />