My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601296_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VAN ALLEN
>
20795
>
2600 - Land Use Program
>
SU-2601296_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/27/2026 11:34:52 AM
Creation date
5/27/2026 11:23:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU-2601296
PE
2601 - SOIL SUITABILITY OR NITRATE LOADING STUDY
STREET_NUMBER
20795
Direction
S
STREET_NAME
VAN ALLEN
STREET_TYPE
RD
City
ESCALON
Zip
95320
APN
24512014
CURRENT_STATUS
In Review
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
20795 S VAN ALLEN RD ESCALON 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL GENERAL REQUIREMENTS <br /> ELECTRICAL SYMBOL LEGEND 1 . ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2025 CEC, CMC, CRC, AND TITLE 24 STANDARDS. <br /> 2. LOAD CENTERS SHALL NOT BE INSTALLED IN BATHROOMS OR CLOSETS. MINIMUM CLEARANCE: 30"W x 36"D. <br /> 110V CONVENIENCE OUTLET 3. ALL GROUNDING SHALL BE INSTALLED IN ACCORDANCE WITH CEC ARTICLE 250-50. <br /> 110V GFCI OUTLET 4. LIGHTING CIRCUITS SHALL NOT EXCEED LOAD LIMITS PER CODE. <br /> ° a a z 5. OUTLETS SHALL BE INSTALLED NOT LESS THAN 15" ABOVE FINISHED FLOOR. <br /> jo 110V WEATHERPROOF OUTLET 6. SWITCHES AND CONTROLS SHALL BE INSTALLED NOT GREATER THAN 48" ABOVE FINISHED FLOOR PER CRC R328.1 .2. <br /> a <br /> SINGLE POLE SWITCH POWER & RECEPTACLES CASAVISION LLC <br /> sys SINGLE POLE SWITCH W/VACANCY 1 . ALL 15- AND 20-AMP RECEPTACLES SHALL BE TAMPER-RESISTANT. <br /> a <br /> SENSOR 2. RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG ANY WALL IS MORE THAN & FROM AN OUTLET. WALLS 2' OR 6507 PACIFIC AVE, #281 <br /> 3040 SL 0 <br /> vm DIMMER SWITCH LONGER REQUIRE AN OUTLET. STOCKTON, CA 95207 <br /> 3. RECEPTACLES IN BATHROOMS, GARAGES, OUTDOORS, UNFINISHED BASEMENTS, AND WITHIN 6' OF SINKS SHALL BE GFCI F. 209-696-8551 <br /> 100 AMP <br /> 3 THREE -WAY SWTICH PROTECTED. CASAVISIONDESIGN@GMAIL.COM <br /> (E) 100A GARAGE PANEL TO REMAIN. 4. ALL 120V, 15- AND 20-AMP BRANCH CIRCUITS SUPPLYING HABITABLE AREAS SHALL BE AFCI PROTECTED PER CEC 210.12. <br /> FED FROM WELL HOUSE SERVICE. 0 RECESSED LIGHT 5. RECEPTACLE SPACING SHALL COMPLY WITH CEC 210.52 (6712' RULE). <br /> 0 CEILING MOUNTED LIGHT FIXTURE 6. PROVIDE ONE GFCI PROTECTED OUTLET WITHIN 36" OF EACH BATHROOM BASIN, LOCATED ON ADJACENT WALL OR PARTITION. <br /> 7. AT LEAST ONE RECEPTACLE SHALL BE INSTALLED IN LAUNDRY AREA, DESIGNATED FOR LAUNDRY EQUIPMENT ONLY. <br /> CEILING LIGHT FIXTURE W/FAN 8. A DEDICATED 20A CIRCUIT IS REQUIRED FOR BATHROOM OUTLETS. THIS CIRCUIT MAY NOT SUPPLY LIGHTS OR OTHER H <br /> EQUIPMENT OUTSIDE THE SAME BATHROOM. <br /> WALL MOUNTED LIGHT 9. OWNER/CONTRACTOR TO VERIFY FINAL DEVICE LOCATIONS PRIOR TO ROUGH INSPECTION. <br /> EXISTING SHOP LIGHTING AND 1" <br /> RECEPTACLES TO REMAIN SD SMOKE DETECTOR LIGHTING & ENERGY COMPLIANCE <br /> BAY 1 SD/CM SMOKE & CARBON MONOXIDE DETECTOR 1 . ALL PERMANENTLY INSTALLED LIGHTING SHALL BE HIGH EFFICACY PER TITLE 24. 0 <br /> EF EXHAUST FAN -50 CFM MIN. <br /> H <br /> SMOKE & CO DETECTION W <br /> L/EF COMBINATION LIGHT/EXHAUST FAN 1 . SMOKE ALARMS SHALL BE HARDWIRED, INTERCONNECTED, AND INSTALLED IN: <br /> PROVIDE OVER-THE-RANGE <br /> GAS OUTLET •• EACH BEDROOM H W W <br /> •• OUTSIDE EACH SLEEPING AREA E-1 STORAGE <br /> 30 GAL. GAS WATER HEATER IN MICROWAVE WITH INTEGRAL EXHAUSTS VANITY LIGHT •• EACH FLOOR LEVEL ✓✓✓^ <br /> ATTIC. PROVIDE DRAIN PAN W/ FAN PER CEC TABLE 150.0-G. MINIMUM <br /> APPROVED DISCHARGE. VENT 100 CFM INTERMITTENT VENTILATION 2. COMBINATION SMOKE/CO DETECTORS REQUIRED IN HALLWAYS OUTSIDE SLEEPING AREAS. O H <br /> PER CPC. REQUIRED, DUCTED TO EXTERIOR(NO 3. SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN 36" OF SUPPLY REGISTERS OR WITHIN DIRECT AIRFLOW PATH. <br /> WH RECIRCULATING TYPE). 4. SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN 3' OF BATHROOM DOORS OR TUBS. W <br /> 0 30 GAL. 5. SMOKE ALARMS SHALL BE INTERCONNECTED SO THAT ACTIVATION OF ONE ACTIVATES ALL. J W O <br /> O � � <br /> MINI-SPLIT / HVAC NOTES U� <br /> / 0 1 . PROVIDE DEDICATED 240 V CIRCUIT FOR MINI-SPLIT HEAT PUMP. w <br /> ug� (D � V) 2. INSTALL WEATHERPROOF DISCONNECT WITHIN SIGHT OF OUTDOOR UNIT PER CEC §440.14. <br /> I <br /> PROVID 20V RECEPTACLE ON LDRY 00 0 00 -�rz� 0 3. EQUIPMENT SHALL MATCH TITLE 24 ENERGY REPORT PERFORMANCE RATING OR APPROVED EQUAL. <br /> DEDICATED 20A LAUNDRY <br /> �, <br /> KITCHEN <br /> CI <br /> RCUI ROVIDE GAS OUTLET � Z <br /> AND DRYE R VENT TO EXTERIOR -------------- <br /> ER MANUFACTURER. m 20 V \ <br /> 1 \ <br /> 8" TUBULAR SKYLIGHT <br /> C) m / / DW <br /> o04 <br /> i <br /> a- \ PROVIDE CONC. <br /> w \ LANDING MIN. <br /> 0 -- \ 1 3'-0" x 3'-0" PER <br /> z BATHROOM - - - - - _- - - - - - ---- CODE. <br /> _ PROVIDE BLOCKING <br /> ( d NAILS AT TRUSS BOTTOM z <br /> / , 4 (TYP.) <br /> CHORD WHERE REQUIRED. O 0 <br /> / / _------- I U) <br /> EF BATH FAN DUCTED - \ <br /> 80CF I TO EXTERIOR W/ SIMP'DTC' @ 48"OC ui <br /> I METAL DUCT. / \ a 7CEN NAILS IN VERT 0 <br /> PROVIDE PER T24 / \� 1 SLOT HT z <br /> NON-BRG STUD 2x PT SILL PLATE ANCHORED Q <br /> / I PARTITION WALL TO SLAB WITH <br /> POWDER-ACTUATED w <br /> 4�1 ---- CONC SOG FASTENERS @ 32"O.C. (TYP.) a <br /> o \ O PER PLAN LE.I Z Q <br /> 04 I __ PROVIDE GYPSUM BOARD AT z 0 <br /> CEILING BELOW(TYP.) ^O U CV <br /> Z �J) <br /> NEW MINI PROVIDE EXTERIOR WALL / <br /> SPLIT 12,000 LIGHT AT EXTERIOR DOOR. O L0 <br /> \\ BTU FIXTURE TO BE CONTROLLED EXISTING GARAGE = a <br /> \ LIVING ROOM BY INTERIOR MANUAL SWITCH HEADER TO REMAIN U N <br /> \ AND INTEGRAL NOTES:TYPICAL NON-LOAD BEARING PARTITION CONNECTIONS <br /> PHOTOCELL/MOTION SENSOR. PROVIDE SLIP CONNECTION AT NON-LOAD BEARING PARTITIONS; MAINTAIN 06 <br /> TUBULAR - ,-� COMPLY WITH CEC 210.70(A)(2) 1/2"GAP BETWEEN TOP PLATE AND TRUSS BOTTOM CHORD TO ALLOW INSULATION PER TITLE 240__�___8" - J ENERGY REPORT <br /> N ---__ _ AND CBEES 150(K)3. VERTICAL MOVEMENT. z <br /> SKYLIGHT <br /> vv-1-C I ANCHOR BOTTOM PLATE TO SLAB WITH POWDER-ACTUATED FASTENERS @ 32" J <br /> ,A' <br /> r7 O.C., 1/2" MINIMUM EDGE DISTANCE(TYP.). J <br /> - ° Z TYP . NON-LOAD-BRG PARTITION Q <br /> NTS DATE: NOTE: <br /> WINDOW HEIGHT AND <br /> / O < N 76040 SL TYPE PER PLAN <br /> a PROVIDE FLASHING AND <br /> / \ ° a WEATHER-RESISTIVE BARRIER AT <br /> / I CUT PLATE TIED WITH STAGGER JOINTS 24IN. OR <br /> WINDOW PER MANUFACTURER <br /> DOUBLE 16 GAGE STEEL STRAP. USE SPLICE PLATES (TYP.) <br /> a/ 4 TOP PLATE PROVIDE JACK AND CRIPPLE STUDS <br /> MINI-SPLIT HEAT I \ --- v a AS REQUIRED AT WINDOW <br /> PUMP CONDENSER BEDROOM <br /> MATCH SET ON CONCRETE // ° ° ABOVE HEADER SIDING SEE I SHEET <br /> PAD, OPENING(TYP.) <br /> CRIPPLE sruDs <br /> PAD, PROVIDE <br /> WEATHERPROOF // ° �' a HEADER -PER A1.1 <br /> WEATHER RESISTIVE 2X4 STUDS AT16"O.C. BLOCK STRUCTURAL HEADER PT SILL PLATE ANCHORED WITH <br /> DISCONNECT PER �� �j ° ° a 1/2" FELT 3 <br /> NOTE 1/2" DIA.x - <br /> BARRIER REQUIRED TO � AROUND POWDER-ACTUATED FASTENERS @ <br /> CEC §440.14 -- Q PIPE KING STUD (FULL EXPANSION JOINT <br /> -- ° LAP THE WEEP SCREED HEIGHT) 32"O.C. <br /> ° ATTACHMENT FLANGE NAIL HEADER TO WEEP SCREED TYP. <br /> d KING STUD WITH <br /> 4 d MATCH EXISTING MINIMUM (4) 16D <br /> 4 NAILS EACH SIDE <br /> SIDEING \ (TYP,), E CONC. DRIVEWAY <br /> ° Q WEEP SCREED SLOPE (E)GARAGE FOUNDATION DATE: 4/25/2026 <br /> 4 ° ° 1"2" <br /> a TO DRAIN <br /> 1/2" STUDS @ <br /> d 11 <br /> ° d Q 4 1 16' ❑,C, JACK STUDS ° a a -�a ° �- AS NOTED <br /> a -� �° UNLESS (TRIMMER) ° <br /> NEW MINI ° PROVIDE (1) <br /> SPLIT 6,000 4 8"ABOX EARTH MIN. d ° a NOTED JACK STUD 4 a_ <br /> EXISTING GFCI RECEPTACLES TO BTU a 2"ABOVE CONC.MIN. j OTHERWISE MIN. EACH a _ _ _ DRAWN BY: M G <br /> REMAIN (WHERE PRESENT). a d I ° SIDE (TYP.) <br /> 4 - <br /> _ I _IL PRESSURE - TITLE: ELECTRICAL PLAN <br /> TREATED <br /> 5040 SH BOATOM <br /> TYPICAL GARAGE DOOR OPENING INFILL CONDITION.VERIFY EXISTING SLAB AND SHEET: <br /> FOUNDATION IN FIELD. <br /> NEITE1 ALL FRAMING LUMBER TO BE DF #2 OR BETTER (TYP,) <br /> ELECTRICAL PLAN TYPICAL WEEP SCREED TYPICAL WALL OPENING FRAMING TYP . GARAGE INFILL STEM WALL El ol <br /> 3/8"=1'-0" NTS NTS NTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.