My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601296_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VAN ALLEN
>
20795
>
2600 - Land Use Program
>
SU-2601296_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/27/2026 11:34:52 AM
Creation date
5/27/2026 11:23:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU-2601296
PE
2601 - SOIL SUITABILITY OR NITRATE LOADING STUDY
STREET_NUMBER
20795
Direction
S
STREET_NAME
VAN ALLEN
STREET_TYPE
RD
City
ESCALON
Zip
95320
APN
24512014
CURRENT_STATUS
In Review
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
20795 S VAN ALLEN RD ESCALON 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLUMBING GENERAL NOTES: -&� ^) <br /> z 1 . ALL PLUMBING WORK SHALL CONFORM TO THE 2025 CALIFORNIA PLUMBING CODE (CPC) AND LOCAL REQUIREMENTS. <br /> 2. CLEANOUTS SHALL BE SAME SIZE AS PIPE AND ACCESSIBLE FROM THE PLAN. INSTALL COVER FLUSH WITH FLOOR OR WALL. <br /> 3. SLEEVES SHALL BE PROVIDED TO PROTECT ALL PIPING THROUGH CONCRETE, MASONRY, AND FLOORS. <br /> 4. ALL PIPING SHALL BE INSTALLED TO MAINTAIN CLEARANCES FROM STRUCTURAL MEMBERS AND BE SECURED USING APPROVED <br /> CLAMPS OR INSULATORS. <br /> 5. BUILDING SEWER SHALL MAINTAIN MINIMUM 1/4" PER FOOT SLOPE FOR 2-1/2" AND SMALLER, AND 1/8" PER FOOT FOR 3" AND LARGER <br /> ADU WATER SERVICE TO BE UNLESS NOTED OTHERWISE. <br /> SUPPLIED FROM EXISTING CASAVISION LLC <br /> ON-SITE SHARED WELL SYSTEM. 6. PIPE SIZES SHOWN ARE DIAGRAMMATIC AND BASED ON TYPICAL CONDITIONS. CONTRACTOR TO VERIFY FINAL PIPE SIZING AND <br /> IF STATIC PRESSURE OR FLOW IS INSUFFICIENT, EXISTING WELL PUMP: 1 1/2 HP, ROUTING IN FIELD PER CPC AND INSPECTOR APPROVAL. <br /> PROVIDE ADDITIONAL STORAGE TANK AND 20 GPM CAPACITY. PRESSURE 6507 PACIFIC AVE, #281 <br /> BOOSTER PUMP SYSTEM AS REQUIRED TO �03/4" C SWITCH CURRENTLY SET AT STOCKTON, CA 95207 <br /> MAINTAIN MINIMUM 40 PSI AT FIXTURES. W APPROXIMATELY 60 PSI. LEGEND: <br /> CONTRACTOR/OWNER SHALL VERIFY WELL 3 H — HOT WATER F. 209-696-8551 <br /> CAPACITY, RECOVERY RATE, AND SYSTEM CASAVISIONDESIGN@GMAIL.COM <br /> PERFORMANCE PRIOR TO FINAL INSTALLATION. C = COLD WATER <br /> 3040 SL S = SEWER LINE <br /> 100 AMP 3 G = GAS LINE <br /> WH = WATER HEATER <br /> -� 30-GALLON GAS WATER HEATER LOCATED IN ATTIC. PROVIDE <br /> PLUMBING VENTING: <br /> DRAIN PAN WITH APPROVED DISCHARGE TO EXTERIOR. <br /> a PROVIDE SERVICE PLATFORM AND MINIMUM 30"WORKING 1 . PLUMBING VENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE (CPC). HORIZONTAL VENTING <br /> CLEARANCE PER CPC. WATER HEATER TO BE ADEQUATELY SHALL BE PERMITTED ONLY ABOVE THE FLOOD-LEVEL RIM OF THE HIGHEST FIXTURE SERVED. EXISTING VENT LOCATIONS, SIZES, <br /> SUPPORTED AND FRAMED BETWEEN TRUSSES; DO NOT CUT AND ROUTING SHALL BE VERIFIED IN FIELD. CONTRACTOR SHALL PROVIDE ADDITIONAL VENTING OR RE-VENTING AS REQUIRED TO 0 <br /> W OR MODIFY TRUSS MEMBERS. PROVIDE VENTING AND H <br /> 3 COMBUSTION AIR PER CPC. MAINTAIN CODE-COMPLIANT TRAP PROTECTION. <br /> 03/4" G 2. BATHROOM EXHAUST FAN SHALL BE DUCTED DIRECTLY TO EXTERIOR IN ACCORDANCE WITH CBC/CMC AND MANUFACTURER <br /> r�►s S GAS CAS —CAS r►s—CaS r►s—CaS Ci CAS GAS REQUIREMENTS. EXHAUST AIR SHALL NOT TERMINATE IN ATTIC OR CONNECT TO PLUMBING VENT SYSTEMS. <br /> Q 1/2" G 7 01/2" G w <br /> W <br /> A ER WATER WATERWATER WATER WATER WATER ATER WATE" �3/ ATER WATER 3 w <br /> I o1/2" C WATER HEATER & FIXTURE NOTES: <br /> F- 1- _s S_ ss ss Hw O3/4"H,Q mw Hw w <br /> 1 . WATER HEATERS SHALL BE STRAPPED WITH METAL STRAPS AT THE TOP AND BOTTOM PER CPC. <br /> 1 01/2" H 2. WATER HEATERS INSTALLED IN ATTICS OR ABOVE FLOOR LEVEL SHALL HAVE A 1-1/2" DEEP PAN WITH A 3/4" DRAIN LINE TO THE <br /> m <br /> � A 7 I EXTERIOR. <br /> O 3. T&P RELIEF VALVE SHALL DISCHARGE BY GRAVITY TO APPROVED EXTERIOR TERMINATION PER CPC. <br /> D F A 4. WATER HEATERS SHALL HAVE PRESSURE AND TEMPERATURE RELIEF VALVES PER CPC AND BE ACCESSIBLE FOR SERVICE. <br /> 03/ " ®® ® ®® i 02" S <br /> A w � Hw Hw Hw Hw Hw s 5. A CONDENSATE DRAIN SHALL BE PROVIDED IF UNIT IS CONDENSING TYPE. <br /> O1/2" G £ I 6. HOT WATER PIPING AND FIRST 5 FEET OF COLD WATER PIPING SHALL BE INSULATED PER TITLE 24 (MIN. R-4 = 1"). <br /> GAS BAS c/2—c Gas 3 3 PROVIDE CLEAN OUT <br /> WA E WATER WAT �� TYP. TUBULAR SKYLIGHT 7. TUBS AND SHOWERS SHALL BE FITTED WITH INDIVIDUAL CONTROL VALVES FOR TEMPERATURE BALANCE (THERMOSTATIC OR Q� <br /> A 01/2" c ATER PRESSURE BALANCE). <br /> O 1/2'm=H 01/2" H <br /> >/2 'WATETER - <br /> 02 s — — — — — — — — N�2„ s GAS GENERAL NOTES: v <br /> O 1/2" <br /> `'� 1 . ALL GAS WORK SHALL COMPLY WITH THE 2025 CALIFORNIA PLUMBING CODE (CPC) AND APPLICABLE LOCAL REQUIREMENTS. <br /> � S2„ <br /> H ss _w ss ss ss ss ss ss s ss ss 2. GAS PIPING SHALL BE SIZED BASED ON TOTAL CONNECTED BTU LOAD AND LONGEST DEVELOPED LENGTH PER CPC TABLES; <br /> PROVIDE CLEAN OUT 0,/ 04„s <br /> H CONTRACTOR TO VERIFY FINAL APPLIANCE RATINGS IN FIELD PRIOR TO INSTALLATION. <br /> 3. CONTRACTOR/OWNER SHALL VERIFY EXISTING GAS SERVICE CAPACITY IS ADEQUATE FOR PROPOSED LOAD; COORDINATE WITH E� <br /> A <br /> UTILITY PROVIDER IF UPGRADE IS REQUIRED. <br /> �O3" s 4. PROVIDE ACCESSIBLE SHUTOFF VALVE AT EACH GAS APPLIANCE AND INSTALL FLEXIBLE CONNECTORS PER MANUFACTURER'S <br /> INSTALLATION INSTRUCTIONS. <br /> A 5. ALL GAS PIPING SHALL BE PRESSURE TESTED AND INSPECTED PRIOR TO CONCEALMENT. <br /> LRW T 6. PROVIDE SEDIMENT TRAP (DRIP LEG) AT EACH GAS-FIRED APPLIANCE PER CPC. <br /> 01/2" C JF <br /> a <br /> 003/4" G �� z <br /> WATER SUPPLY SYSTEM: <br /> 1 . PROVIDE STORAGE AND BOOSTER SYSTEM AS REQUIRED BASED ON WELL CAPACITY AND PRESSURE TESTING. <br /> 2. TANK SHALL BE SUPPLIED BY EXISTING SHARED WELL. LL.I <br /> 3. PROVIDE A 1 HP BOOSTER PUMP SYSTEM WITH 40-GALLON DIAPHRAGM PRESSURE TANK, SIZED TO MAINTAIN 50-70 PSI AT THE Q <br /> I RESIDENCE UNDER NORMAL OPERATING CONDITIONS. Z <br /> 4. INCLUDE THE FOLLOWING: Q <br /> 4.1. FLOAT VALVE CONTROL WITHIN BUFFER TANK FOR AUTOMATIC FILL CONTROL W z <br /> ® 4.2. PROPER BACKFLOW PREVENTION DEVICE PER LOCAL JURISDICTION REQUIREMENTS w Z Q <br /> 4.3. ISOLATION VALVES AND UNIONS FOR SERVICEABILITY z ~ N <br /> 4.4. PRESSURE GAUGE ON DISCHARGE SIDE OF BOOSTER SYSTEM 3 U <br /> uj <br /> 4.5. GENERAL CONTRACTOR SHALL VERIFY: 0 O <br /> 4.6. EXISTING WELL PUMP CAPACITY (GPM) = a <br /> to 4.7. ADEQUACY OF WELL RECOVERY RATE N <br /> C)4.8. SHARED WELL CAPACITY TO SUPPORT ALL CONNECTED RESIDENCES <br /> 4.9. SYSTEM SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS AND ALL APPLICABLE LOCAL PLUMBING AND HEALTH 06 <br /> ® DEPARTMENT REGULATIONS. Z <br /> a LLI <br /> J <br /> J <br /> Q <br /> ACRYLIC DOMF <br /> SELF-TAPPING <br /> ALUMINUM DATE: NOTE: <br /> SCREW — FLASHING <br /> N <br /> a - <br /> SHEET METAL <br /> H 12' SCREW - <br /> ROOFING <br /> N <br /> l 3l4"PLYWOOD <br /> l <br /> IF SHEATHING <br /> to STAINLESS <br /> STEEL SCREW '"' -6 LIGHT PIPE <br /> a <br /> FOIL TAPE <br /> a <br /> u DATE: G <br /> FLAT HEAD SCREW STAINLESS 4/25/ZO26 <br /> O PROPOSED 250-GALLON ABOVE-GROUND ,WITH SPEED NUT STEEL SCREW <br /> GAS <br /> PROPANE TANK. INSTALL PER FIRE CODE AND SCALE: AS NOTED <br /> PROPANE SUPPLIER REQUIREMENTS; VERIFY <br /> CLEARANCES AND ACCESS. <br /> DRAWN BY: <br /> TRIM RING SHEETROCK MG <br /> ! CEILING <br /> DIFFUSER TITLE: PLUMBING PLAN <br /> ROOF MOUNf' <br /> SHEET: <br /> PLUMBING PLAN TUBULAR SKYLIGHT DETAIL Pi 00 <br /> 1/4"=1'-0" 1 <br /> N TS <br />
The URL can be used to link to this page
Your browser does not support the video tag.