My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601296_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VAN ALLEN
>
20795
>
2600 - Land Use Program
>
SU-2601296_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/27/2026 11:34:52 AM
Creation date
5/27/2026 11:23:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU-2601296
PE
2601 - SOIL SUITABILITY OR NITRATE LOADING STUDY
STREET_NUMBER
20795
Direction
S
STREET_NAME
VAN ALLEN
STREET_TYPE
RD
City
ESCALON
Zip
95320
APN
24512014
CURRENT_STATUS
In Review
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
20795 S VAN ALLEN RD ESCALON 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> WELL SHED SEPTIC SYSTEM - GENERAL <br /> (EXISTING) • SEPTIC SYSTEM LAYOUT SHOWN IS CONCEPTUAL FOR PLANNING AND PERMIT COORDINATION ONLY. <br /> • FINAL SYSTEM DESIGN, SIZING, AND INSTALLATION SHALL BE APPROVED BY SAN JOAQUIN COUNTY ENVIRONMENTAL <br /> z HEALTH PRIOR TO CONSTRUCTION. <br /> • PERCOLATION TESTING AND SOIL SUITABILITY STUDY SHALL BE PERFORMED IF REQUIRED BY ENVIRONMENTAL HEALTH. <br /> OWNER/CONTRACTOR RESPONSIBLE FOR TESTING AND ASSOCIATED REPORTS. <br /> • NO INSTALLATION SHALL OCCUR WITHOUT APPROVED OWTS PERMIT. <br /> • SYSTEM SHALL COMPLY WITH SAN JOAQUIN COUNTY OWTS STANDARDS (LAMP) AND APPLICABLE REGULATIONS. CASAVISION LLC <br /> 6507 PACIFIC AVE, #284 <br /> DESIGN BASIS STOCKTON, CA 95207 <br /> • SEPTIC TANK AND DISPERSAL FIELD SIZING SHALL BE BASED ON APPROVED BEDROOM COUNT AND COUNTY STANDARDS. F. 209-696-8551 <br /> 86 0 MINIMUM SEPTIC TANK CAPACITY SHALL BE PER APPROVED SSNLS REPORT. CASAVISIONDESIGN@GMAIL.COM <br /> • FINAL LEACH FIELD SIZING SHALL BE BASED ON APPROVED PERCOLATION TEST RESULTS AND SOIL EVALUATION. <br /> • A 100% RESERVE DISPERSAL AREA SHALL BE PROVIDED FOR FUTURE REPLACEMENT FIELD. <br /> • SYSTEM DESIGNED FOR DOMESTIC WASTEWATER ONLY. <br /> H <br /> TANK & MATERIAL REQUIREMENTS <br /> • SEPTIC TANK SHALL BE WATERTIGHT REINFORCED CONCRETE OR APPROVED POLYETHYLENE TANK. <br /> 100, 0 TANK SHALL BE INSTALLED LEVEL ON PREPARED BASE PER MANUFACTURER AND COUNTY REQUIREMENTS. Q <br /> • ACCESS RISERS SHALL BE PROVIDED WHERE REQUIRED BY ENVIRONMENTAL HEALTH. <br /> w • • <br /> z . . . . . . . . . . . W W <br /> - - - - - - - - - - - - - - - <br /> Zj LOCATION & SITE LIMITATIONS <br /> - - - - - - - - - - - - - - - <br /> oIN <br /> ALL OWTS COMPONENTS SHALL MAINTAIN MINIMUM SETBACKS PER COUNTY STANDARDS (INCLUDING STRUCTURES, <br /> off . . <br /> MR# <br /> 00 0� EXISTING DETACHED GARAGE WELLS, AND PROPERTY LINES). E H <br /> CV W 1,260 SQFT PROVIDE 4" PVC (SCH 40) O <br /> a • • - - - - - - - - - - - - - - - - - - <br /> BUILDING SEWER TO SEPTIC MINIMUM 100 FT SEPARATION FROM PRIVATE WELL UNLESS OTHERWISE APPROVED BY ENVIRONMENTAL HEALTH. <br /> 0 TANK. INSTALL WITH MIN. 12" W <br /> • COVER AND 1/4" PER FOOT LEACH FIELD AND RESERVE AREA SHALL REMAIN FREE OF STRUCTURES, PAVING, DRIVEWAYS, AND HEAVY ~J W <br /> SLOPE. PROVIDE APPROVED <br /> - - - - - - - - - - - - - - <br /> . • • . . . . . . • . PIPE PROTECTION WHERE CONSTRUCTION TRAFFIC. 0 0 <br /> NECESSARY TO PREVENT <br /> DAMAGE. DISPOSAL FIELD SHALL NOT BE INSTALLED ON SLOPES EXCEEDING COUNTY ALLOWABLE LIMITS. U� <br /> p-, g <br /> W <br /> • INSTALLATION IN FLOOD-PRONE AREAS OR AREAS WITH HIGH GROUNDWATER MAY REQUIRE SPECIAL DESIGN AND- - - -- - - -- - - - -- - - -- - - -- - - - -- - - -- <br /> r� <br /> - � � APPROVAL. v <br /> ��1`. . . . . . . . . . . . . . �� <br /> . . . . . . . . . . . . . - - - - - - - - - - - - - - - - - <br /> 17 2 \ OPERATION & MAINTENANCE O <br /> 9 e a ° �� <br /> - 5� <br /> . . . . . . . . . . - . \ / SEPTIC TANK SHALL BE PUMPED AS REQUIRED BY COUNTY (TYPICALLY EVERY 3 YEARS). <br /> . . . . . . . . . . . . a a <br /> (N) 1,600 GALLON <br /> • EFFLUENT FILTERS, IF PROVIDED, SHALL BE MAINTAINED PER MANUFACTURER RECOMMENDATIONS. <br /> " " " SEPTIC TANK � <br /> 1 PER APPROVED 3 01STING 90 SQFTINGLE FAMILY HOME . STORMWATER, ROOF DRAINAGE, GARAGE WASH WATER, POOL DISCHARGE, WATER SOFTENER BACKWASH, OR <br /> SSNLS REPORT APN: 07049029 <br /> 22'-2" DISTRIBUTION - NON-DOMESTIC WASTE SHALL NOT DISCHARGE INTO SYSTEM. <br /> "-"•••_•_-_-_--_-_••••••_••_-_-_- 40� BOX(TYP.) 13 <br /> • ALL SYSTEM COMPONENTS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND SERVICE. <br /> PROPOSED 250 GAL. PROPANE <br /> folF/ <br /> ' TANK W/9' X T CONC. PAD. <br /> _ T T <br /> . . . . . . . . . . . . . . <br /> . . . . . . . . . . . . . . . <br /> DISCLAIMER z <br /> 15' . SEPTIC SYSTEM LAYOUT SHOWN IS CONCEPTUAL ONLY AND DOES NOT REPRESENT A FINAL ENGINEERED DESIGN. O <br /> . . . . . . . . . . . <br /> . . . . . . . . . . . _ / / / / /I �, �, v, • OWNER/CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED ENVIRONMENTAL HEALTH APPROVALS, PERMITS, <br /> 0 0 o INSPECTIONS, AND PERCOLATION TESTING. W <br /> . . . . . . . . . . . . / /I 1r-I 1r-I Trl I �i \���\ 0 <br /> / FUTURE LEACH /I m m m �� • FINAL SEPTIC SYSTEM DESIGN AND INSTALLATION SHALL BE PERFORMED IN ACCORDANCE WITH APPROVED COUNTY z <br /> GRAVEL.DR-IVE.: FIELD / 100% D D D =T� \���� PERMITS AND ENVIRONMENTAL HEALTH REQUIREMENTS. Q <br /> .WAY:. . . . . . . . . . I / RESERVE AREA w <br /> (CONCEPTUAL). 2 2 2 <br /> • ANY ENGINEERED OR ALTERNATIVE SYSTEM, IF REQUIRED, SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL. w Z Q/ KEEP CLEAR OF /I r r r O <br /> DRIVEWAYS, I m m z I r , z ~ CN <br /> . . . . . . . . . . - / STRUCTURES & / / I I I I SEPTIC SYSTEM NOTES p � <br /> TRAFFIC. TRENCH I _----- APPROXIMATE EXISTING SEPTIC SYSTEM LOCATION AND LINES --------- - <br /> � <br /> :.:.:...:.:.....:.:.:...:. / SPACING AND / / I BASED ON SSNLS REPORT AND OWNER INFORMATION. NOT FIELD I I I • A NEW SEPTIC SYSTEM SHALL BE INSTALLED TO SERVE THE PROPOSED ADU IN ACCORDANCE WITH SAN JOAQUIN = a <br /> / F R L LOCATION / I I LEACH FIELD (NEW) VERIFIED. CONTRACTOR TO VERIFY IN FIELD. I I I U N <br /> ' I I �' PER SJC EHD I -� COUNTY ENVIRONMENTAL HEALTH DEPARTMENT (SJC EHD) REQUIREMENTS. <br /> 9 ENVIRONMENTAL STANDARDS --------------------------------------------------- 06 <br /> / HEALTH. /I 6, • SEPTIC SYSTEM DESIGN SHALL BE BASED ON THE APPROVED SOIL SUITABILITY / NITRATE LOADING STUDY (SSNLS) z <br /> PREPARED BY LIVE OAK GEOENVIRONMENTAL, INC., DATED APRIL 23, 2026. J <br /> --------------------------------------------------J <br /> . . . . . . . . . . . . . I/ / / / / /I • A 1 ,600 GALLON SEPTIC TANK IS REQUIRED PER APPROVED SSNLS REPORT. J <br /> 30.0' PROPERTY SETBACK • LEACH FIELD DESIGN, LENGTH, AND CONFIGURATION SHALL BE PER APPROVED SSNLS AND SJC EHD REQUIREMENTS. Q <br /> • A 100% FUTURE REPLACEMENT AREA SHALL BE PROVIDED AND MAINTAINED FREE OF STRUCTURES, PAVING, OR OTHER DATE: NOTE: <br /> OBSTRUCTIONS. <br /> • MINIMUM REQUIRED SEPARATION SHALL BE MAINTAINED BETWEEN THE BOTTOM OF THE DISPERSAL SYSTEM AND <br /> / / / / /I GROUNDWATER PER COUNTY REQUIREMENTS. <br /> 34'-H" 30' • EXISTING SEPTIC SYSTEM SERVING THE MAIN RESIDENCE SHALL REMAIN. <br /> .......................... . ALL WORK SHALL COMPLY WITH SAN JOAQUIN COUNTY ON-SITE WASTEWATER TREATMENT SYSTEM STANDARDS (2017) <br /> . . / / / / / / /I AND ALL APPLICABLE LOCAL AND STATE REGULATIONS. <br /> - I/ / / / / / /I • FINAL SEPTIC SYSTEM DESIGN AND INSTALLATION SHALL BE PERMITTED AND APPROVED BY SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH. <br /> . . . . . . . . . . . . . . -� 227.0 _ <br /> PROPERTY LINE <br /> DATE: 3/18/2026 <br /> SCALE: AS NOTED <br /> S VAN ALLEN RD DRAWN BY: MG <br /> Jill <br /> TITLE: PLOT PLAN <br /> SHEET: <br /> SEPTIC SYSTEM spi 00 <br /> 3/32"=1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.