Laserfiche WebLink
A4OM <br /> • Clean out the dust using a shop vacuum. Note: Do not use a shop vacuum to clean out the dust from drilling if the <br /> hole extends all the way through the sub-slab. <br /> • Continue drilling down using a 5/16"diameter concrete bit to below the slab. <br /> • Use the drill bit to measure the thickness of the slab and record the value. <br /> Note: If the slab is very thick(e.g., 18"),the 5/16"drill bit may not be long enough to reach the bottom of the slab. In this <br /> case, use a larger, longer drill bit for the entire length of the slab. <br /> • Hand auger to 5 feet below slab to install vapor probe. <br /> Vapor Pin® Installation: <br /> Drill down into the slab approximately 1 to 2 inches using a rotary hammer drill with a 1'/2-inch diameter drill bit. <br /> • Clean out the dust using a shop vacuum. Note: Do not use a shop vacuum to clean out the dust from drilling if the <br /> hole extends all the way through the sub-slab. <br /> • Continue drilling down using a 5/8"diameter concrete bit to below the slab. <br /> • Use the drill bit to measure the thickness of the slab and record the value. <br /> • Assemble the Vapor Pin® sampling device and Vapor Pin® sleeve. <br /> • Place the lower end of the Vapor Pin sampling device assembly into the drilled hole. Place the small hole located in <br /> the handle of the Installation/Extraction tool, over the Vapor Pin®to protect the barb fitting and tap the Vapor Pin® <br /> into place using a dead blow hammer. Make sure the Installation/Extraction tool is aligned parallel to the Vapor <br /> Pin® to avoid damaging the barb. <br /> • During installation,the Vapor Pin® sleeve may form a slight bulge between the slab and the Vapor Pin® sampling <br /> device shoulder. <br /> • Place the Vapor Pin® cap on the Vapor Pin® to prevent vapor loss prior to sampling. <br /> • Allow 20 minutes or more for the sub-slab soil-gas conditions to re-equilibrate prior to sampling. <br /> 4.3 SEALING,MARKING,RECORDKEEPING <br /> Sub-slab monitoring probe installation use modeling clay to seal the hole until the sampling train configuration is set(Step 4 <br /> under Sampling Procedures below). <br /> Label the SSMP with indelible marker or paint pen on removable duct tape. <br /> Record all measurements in the project logbook, including: <br /> • Slab thickness; <br /> • Borehole diameter; and <br /> • Time when clay seal was installed <br />