My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR2501523
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
622
>
2900 - Site Mitigation Program
>
SR2501523
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2026 11:50:38 AM
Creation date
6/17/2026 9:25:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
SR2501523
PE
2900 - Site Mitigation Program
STREET_NUMBER
622
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16715050
CURRENT_STATUS
In Review
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
622 E CHARTER WAY STOCKTON 95206
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
936
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A4OM <br /> 2.2.1 QA/QC Sample Designation <br /> Sample duplicates will be labeled numerically and will not indicate the point from which the <br /> sample was collected. Times for all duplicate samples will be 12:00 on the day of sampling. <br /> 2.3 Sample Collection <br /> Prior to sampling, each canister will have its vacuum checked with a dedicated gauge, with <br /> the expected vacuum ranging from -28 to -29" Hg. If any canister differs from the others by <br /> 3" Hg or more, the canister will not be used as the integrity of the canister may have been <br /> compromised. <br /> Building conditions should reflect current occupancy conditions, including typical use of any <br /> HVAC system. The occupant will not make changes to the building envelope during <br /> sampling that could potentially alter results (i.e. leaving a window or door open). <br /> 1) The canister will be placed such that the inlet is at breathing height, between 3 ft and 5 ft <br /> above the floor. <br /> a) This height can be achieved using a stand or table, if available, or through attaching <br /> a short length of stainless-steel or Teflon tubing to the Summa®canister using <br /> stainless steel air-tight fitting and attached to the inlet of the tubing. <br /> b) The intake of the tubing will be located at approximately breathing height. <br /> 2) Both ambient air canisters and indoor air canisters will be set-up prior to opening the <br /> canister valves. <br /> 3) Once the canisters are in place, the valve of the indoor air canister will be opened, and <br /> the start time and vacuum gauge reading will be recorded. This process is repeated for <br /> each other canister as quickly as possible. <br /> 4) Each indoor air canister will be equipped with an 8-hour flow controller, for commercial <br /> non-residential buildings, or a 24-hour flow controller for residential buildings. After 8 or <br /> 24 hours and when the pressure is at approximately 5" Hg, the valve will be closed, and <br /> the final vacuum and time will be recorded. <br /> 2.4 Ambient Air Samples <br /> Ambient (i.e., outdoor) air samples are helpful to identify potential contributions to indoor air <br /> concentrations from building air exchange with outdoor air and will be collected any time <br /> indoor air samples are collected. <br /> • Locations for ambient air samples will include one upwind, one downwind, and one <br /> crosswind location. <br /> • Ambient air sampling will be conducted concurrently with indoor air sampling. Sample <br /> locations will be outside and adjacent to the targeted building. Per USEPA (2015), <br />
The URL can be used to link to this page
Your browser does not support the video tag.