B.8.ELECTRICAL HAZARDS ® Applicable ❑ Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> ® BASIC ELECTRICAL HAZARDS TO E Follow safe work practices: <br /> SKILLED NON ELECTRICAL WORKERS • Control water-related/wet-location hazards in a manner appropriate for the job tasks/equipment/tool. <br /> Equipment/tool use/operation,use . Never touch electrical equipment if you are wet,or standing in water or on wet surfaces. <br /> i of extension cords,working near . Use extension cords/power cords properly,prevent damage,take out of service if damaged. <br /> electrical equipment. • Inspect tool/equipment/extension cords/power cords/welding cables before each use;do not use if damaged. <br /> • Use GFCI-protected outlet or portable GFCI in wet locations,outdoors,basements,concrete floors. <br /> Hazards:Electrical shock,secondary a Ensure live parts are guarded,enclosures secure. <br /> hazards(falls,other injuries). . Enclosures,circuits properly labeled. <br /> Geosyntec Procedure(s):HS-121-Electrical Safety <br /> HANDS-ON ELECTRICAL WORK BY 1 ❑Implement electrical safe work practices pertaining to: <br /> ELECTRICAL WORKER/TECHNICIAN: i • Worker training/qualification(Level 1,Level 2,Level 3) <br /> ❑Voltage<50 v i • General electrical safe work practices,grounding,use of GFCls <br /> ❑Voltage 50-600v • Safe work practices during diagnostics/troubleshooting,maintenance,repair <br /> ❑Voltage>600v I <br /> • Safe design features for electrical equipment <br /> ❑AC ❑DC ❑3-phase ! • Arc flash protection <br /> I <br /> ❑Battery and/or solar power <br /> El Capacitor/transformer i Geosyntec Procedure(s):HS-121-Electrical Safety,HS-129-High Voltage Electricity Safety <br /> I <br /> rJ <br /> LOCKOUT/TAGOUT OF ELECTRICAL i ❑Implement control-of-hazardous-energy practices(lockout/tagout),provide lockout/tagout locks and <br /> ENERGY devices,training workers,designate"authorized"personnel,notify"affected"personnel. <br /> i Geosyntec Procedure(s):HS-119-Lockout Tagout,HS-121-Electrical Safety <br /> IMPORTANTI This work may/will I ❑Follow safe work practices per Section B.9.,"Utility Related Hazards" <br /> include close proximity to electric I <br /> utility lines. <br /> B.9. UTILITY RELATED HAZARDS ® Applicable ❑ Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> ® i OVERHEAD,ABOVE-GROUND i E Maintain proper clearance,employ other appropriate precautions for the conditions. <br /> i UTILITIES ! Geosyntec Procedure(s):HS-304-Overhead Electrical Lines <br /> ® UNDERGROUND UTILITIES ! E Confirm appropriate underground utility clearance procedures have been completed prior to ground <br /> penetrations,and employ other utility clearance/locator practices,as appropriate for conditions. <br /> i E Hand digging or vacuum post-holing within 3'of utility locations or other high risk condition. <br /> B.12. INFECTIOUS(ALLERGENIC BIOHAZARDS ® Applicable ❑ Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: <br /> Spiders,snakes,ticks <br /> ® ❑Wastewater,sewer E Low hazard-use basic hygiene practices,protective gloves,provide for hand washing. <br /> ❑Bird Guano I IDMore severe hazard-add protective clothing,respirator/dust mask,decon,as appropriate. <br /> ❑Mold,fungi,Valley Fever j ❑For human pathogens use"Universal Precautions"per B!oodborne Pathogen Program. <br /> ❑Bloodborne pathogens I <br /> ®Other(describe above) Geosyntec Procedure(s):HS-133-Bloodhorne Pathogens <br /> B.13.COMMERCIAL CHEMICAL PRODUCTS ® Applicable ❑ Not Applicable,Not Anticipated <br /> EXPLANATORY NOTES,CLARIFICATIONS: Alconox,Methanol,Hydrochloric Acid,Bentonite,Portland cement <br /> ® PRODUCTS REGULATED BY HAZARD E Safety Data Sheets available,either on site or readily available within same work shift,containers labelled <br /> COMMUNICATION STANDARD properly,workers trained/oriented on hazards <br /> E For subcontractor use of chemical products,coordinate/discuss during safety meetings. <br /> E Conduct air monitoring,as appropriate(see Part C,"Air Monitoring,Worker Exposure Monitoring"). <br /> ❑ ! COMPRESSED GAS(flammable or ❑Secure cylinders upright,caps on when not in use,handle with care,prevent damage. <br /> nonflammable) ❑Propane cylinders not in use must be stored outdoors in cage or similar secure enclosure. <br /> ❑Ensure acetylene cylinders NOT secured to steel arc welding bench. <br /> 1 ❑Store/use in a manner to prevent asphyxiation hazard. <br /> ❑Segregate oxygen and fuel gases by distance(20')or barrier. <br /> ❑Control ignition sources. <br /> I ❑"No smoking"signage at cylinder storage area for flammable gases. <br /> i ❑Use/store in a manner to control inhalation exposure hazards,PPE,air monitoring. <br /> FLAMMABLE/COMBUSTIBLE ❑Proper storage(flam.storage cabinets,other storage precautions). <br /> LIQUIDS i ❑Use proper fuel safety can(metal fuel can preferred). <br /> ❑Control ignition sources. <br /> Geosyntec THA(ver.2)—UST Data Gap Investigation December 29,2018 <br /> Port of Stockton,WR2501 Page 7 <br /> consultants <br />