Laserfiche WebLink
Programmatic Sampling and Analysis Plan Project Number:60657245 <br /> Table 2.3 —Quality Assurance Objectives <br /> QC Sample and/or Activity <br /> Data Quality Indicators Use to Assess Measurement <br /> DQIs Measurement Performance Criteria Performance <br /> Precision—Laboratory See laboratory limits MS/MSDs and/or LCS/LCSD <br /> For Laboratory Duplicates the following criteria will be Laboratory Duplicates <br /> used: <br /> • If the parent sample and duplicate values are >5xRL, <br /> then <20% RPD for water samples(<35%soil and <br /> other matrices). <br /> • If the parent sample or duplicate sample value is <br /> <5xRL,then absolute difference is<1 xRL for water <br /> samples <2xRL for soil and other matrices). <br /> See analytical method and/or DoD QSM 5.3 Calibration—Initial and <br /> Continuing <br /> Precision—Field For Field Duplicates the following criteria will be used: Field Duplicates <br /> • If the parent sample and duplicate values are >5xRL, <br /> then <30% RPD for water samples(<50%soil and <br /> other matrices). <br /> • If the parent sample or duplicate sample value is <br /> <5xRL,then absolute difference is<2xRL for water <br /> samples <3xRL for soil and other matrices). <br /> Accuracy/Bias- See DoD QSM 5.3 LCS, MS/MSD, and Surrogate <br /> Laboratory recoveries <br /> See analytical method and/or DoD QSM 5.3 Calibration—Initial and <br /> Continuing <br /> Accuracy/Bias No Target Analyte Detected >1/2 MDL Method Blanks <br /> Contamination <br /> Sensitivity Results reported to the MDL; RLs must meet screening Quarterly verification: RLs meet <br /> criteria the criteria outlined in Order <br /> WQ 2021-0006-DWQ <br /> Completeness 90% Data Completeness Check <br /> >—Greater Than MDL—Method Detection Limit <br /> <—Less Than MS—Matrix Spike <br /> %—Percent MSD—Matrix Spike Duplicate <br /> DoD—Department of Defense QSM—Quality Systems Manual <br /> LCS—Laboratory Control Sample RL—Reporting Limit <br /> LCSD—Laboratory Control Sample Duplicate <br /> 2.4 Data Review and Validation <br /> 2.4.1 Data Review, Verification, and Validation <br /> Decision and recommendations will be based on verified or validated data. The process through <br /> which data will be accepted or rejected will be based on specific data verification and validation <br /> criteria. AECOM personnel experienced with sampling and analytical protocols and procedures <br /> will perform the data validation in accordance with the established criteria and the intended use <br /> of the data. <br /> Stage 213 data validation will be performed on laboratory data packages. This will include review <br /> of chain of custody forms, laboratory receipt checklist, sample related QC data and QC <br /> acceptance criteria linked to field samples, requested spike analytes as appropriate (LCS, matrix <br /> spikes), QC sample frequency, initial calibration summaries, initial and continuing calibration <br /> verification summaries, instrument performance check summaries, and preparation logs. Data <br /> validation qualifiers will be applied as necessary in accordance with Table B-15 of DoD QSM <br /> version 5.3, or the associated applicable criteria. <br /> AECOM <br /> 7 <br />