Laserfiche WebLink
S 11 <br />1 N J OAQ U <br />I I N Environmental Health Department <br />COUNTY— AMENDED <br />1/9/2020 <br />Large Quantity Hazardous Waste Generator Inspection Report <br />Facility Name: Facility Address: Date: <br />PROFLEET TRUCK LUBE 1 15453 N THORNTON RD, LODI January 08, 2020 <br />SUMMARY OF VIOLATIONS <br />CLASS I,CLASS II,or MINOR-Notice to Comply) <br />Item# Remarks <br />403 CCR 66265.173 Failed to keep hazardous waste containers closed except when adding or removing hazardous <br />waste. <br />OBSERVATION:The following open hazardous waste storage containers were observed outside: <br />Two black 55 gallon steel drums containing paper oil filters(full)were missing rings to secure the lid. <br />REGULATION GUIDANCE:A container holding hazardous waste shall always be closed during transfer and <br />storage, except when it is necessary to add or remove waste. <br />CORRECTIVE ACTION: Immediately close these containers and ensure all hazardous waste containers are closed <br />when not adding or removing waste. Provide a corrective action statement and supporting documentation to the <br />San Joaquin County Environmental Health Department within 30 days. <br />This is a minor violation. <br />501 CCR 66262.34(f) Failed to completely label stationary hazardous waste tanks. <br />OBSERVATION: The facility has a 4000 gallon used oil tank. The used oil tank was missing the current <br />accumulation start date. <br />REGULATION GUIDANCE: All hazardous waste tanks shall be marked with the words"Hazardous Waste"and the <br />accumulation start date. <br />CORRECTIVE ACTION: Label the hazardous waste tank with the words"Hazardous Waste"and the accumulation <br />start date. Provide a corrective action statement and supporting documentation to the San Joaquin County <br />Environmental Health Department(EHD)within 30 days. <br />This is a minor violation. <br />512 CCR 66265.192(h) Failure to obtain a reassessment of a tank system within 5 years or as required. <br />OBSERVATION: This facility has a 4000 gallon used oil tank. The tank assessment was not available for review <br />during the inspection. <br />REGULATION GUIDANCE: <br />The assessment specified in subsection (k)of this section shall be obtained prior to placing a new tank system in <br />service and shall be kept on file at the facility.This assessment shall be reviewed and certified by an independent, <br />qualified, professional engineer, registered in California, in accordance with section 66270.11(d), attesting that the <br />tank system has sufficient structural integrity and is acceptable for the transferring, storing and treating of hazardous <br />waste.The assessment shall be valid for a maximum period of five (5)years or the remaining service life of the tank <br />system, as stated in the engineer's assessment,whichever is less. <br />CORRECTIVE ACTION: Provide a copy of the current hazardous waste tank assessment to the San Joaquin <br />County Environmental Health Department(EHD). If the tank needs to be reassessed, immediately get a tank <br />reassessment and provide it to the EHD. Provide a corrective action statement and supporting documentation to <br />the San Joaquin County Environmental Health Department(EHD)within 30 days. <br />This is a Class II violation. <br />FA0015491 PR0522841 SCO01 01/08/2020 <br />EHD 22-02 Rev.9/20/2019 Page 8 of 10 Large Quantity Hazardous Waste Generator OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com