Laserfiche WebLink
SPECIFICATIONS <br />MACHINE RATINGS <br />Standard N/A <br />As continued product improvement is a policy of Hobart, specifications are subject to change without notice. <br />LXeR and LXePR <br />advansgs HOT AND COLD <br />Page 4 of 4 <br />F40336 (REV. 03/13) <br />• LXePR: Sanitation is accomplished by injection of proper <br />amount of sodium hypochlorite solution (liquid bleach) into <br />final rinse water to achieve a minimum of 50PPM sanitizing <br />solution. Injection of sodium hypochlorite is accomplished <br />by a built-in sanitizing chemical pump. Minimum required hot <br />water temperature is 120°F. <br />- Potable water rinse to remove chemical residue. <br />- To be used with sanitizer approved for use with post <br />sanitizing rinse <br />• CHECK SANITIZER CONCENTRATION: PuriRinse must be <br />off (hold Wash button for 5 seconds). Verify that there is suffi­ <br />cient chemical supply. Run cycle and use test trips on wetted <br />surface of glasses after cycle is complete. If concentration is <br />below minimum required, contact your local Hobart Service <br />office. <br />ENERGY RECOVERY: Heat energy is recovered from the con­ <br />densation of vapors in the chamber at the end of each cycle. This <br />pre-heats the water for the next rinse cycle from 55°F up to 140°F. <br />PUMPED DRAIN: Machine automatically drains water through a <br />built-in pump. Maximum 38" drain height permitted. <br />ELECTRIC BOOSTER HEATER: 4.9 KW electric booster with <br />Sense-A-Temp " technology adequately sized to raise 55°F inlet <br />water to 180°F, with the aid of the energy recovery system. <br />RACKING: Machines accommodate racks from 10" x 20“ to 20" x <br />20". Also accepts 16" x 18" cafeteria trays. <br />NOTE: Certain materials, including silver, aluminum and pewter <br />are attacked by Sodium Hypochlorite solution in the chemical <br />sanitizing mode of operation. <br />SPECIFICATIONS: Listed by Underwriters Laboratories Inc. and <br />NSF International. <br />DESIGN: Front opening, equipped for installation in either free­ <br />standing or undercounter-type operations. <br />CONSTRUCTION: 300 series stainless steel tank, door and top <br />panel. <br />PUMP: Centrifugal-type, integral with motor, horizontally <br />mounted. Pump capacity 38 gpm. <br />MOTOR: Single phase, furnished for all electrical specifications. <br />Factory sealed lubrication. Inherent overload protection with auto <br />reset. <br />WASH AND RINSE CYCLE: Complete automatic type, controlled <br />by solid-state electronics. Cycle may be interrupted any time by <br />opening door. Cycle continues when door is closed. <br />• Initial cycle fills wash tank, to be recirculated each wash cycle. <br />Some wash water is drained off before rinse cycle. Rinse cycle <br />refreshes wash water and tank heat. <br />RINSE PUMP: Powered by a single phase motor, the rinse pump <br />is made of high strength engineered composite material. <br />BLOWER: The blower is a 60mm x 300mm tangential wheel <br />powered by a 2-pole single phase motor for quiet and reliable <br />operation, LXeR only. <br />CONDENSER COIL: The condensing system uses a tube and fin <br />coil constructed of copper and corrosion resistant aluminum. <br />The condenser coil allows for energy recovery from waste heat <br />in the moisture laden air that would normally escape into the <br />environment after a dishwashing cycle, LXeR only. <br />RINSE AND SANITATION: <br />• LXeR: Sanitation is accomplished by means of a built-in <br />booster heater designed to raise temperature of water to a <br />minimum of 180°F from an incoming water temperature of <br />55°F. <br />N/A <br />120° <br />N/A <br />1.14 <br />Light <br />30 <br />750 <br />1080 <br />4.9 KW <br />.62 <br />Racks per Hour Rate <br />Dishes per Hour (25 per Rack Avg.)_____________ <br />Glasses per Hour (36 per Rack Avg.)____________ <br />Controls______________________________________ <br />Tank Capacity - Gallons________________________ <br />Overall Dimensions - H x W x D_________________ <br />Cycle Time - Seconds <br />Tank Heat <br />Electric Booster Heater <br />Water Usage Per Rack - Gallons <br />Drain Design <br />Door Opening Height <br />Detergent Pump <br />Rinse-Aid Pump <br />Delime Pump <br />Sanitizer Pump________________________________ <br />Chemical Prime (auto prime)____________________ <br />Peak Drain Flow - GPM________________________ <br />Advanced Service Diagnostics <br />Advanced Cleaning Cycle <br />TO^Rise Sense-A-Temp'“ Booster Heater <br />Incoming Water Temperature Required (minimum) <br />F40336 - LXeR and LXePR advansgs Hot and Cold <br />LITHO IN U.S.A. (H-01) P>>n<rJ On Recycled <br />Heavy <br />13 <br />325 <br />468 <br />LXePR <br />Normal <br />29 <br />725 <br />1044 <br />Heavy <br />14 <br />350 <br />504 <br />Microcomputer <br />Z9 <br />Pumped <br />17“ <br />Standard <br />Standard <br />Standard <br />| <br />Standard <br />4.0 <br />Standard <br />Standard <br />Standard <br />55 <br />LXeR <br />Normal <br />24 <br />600 <br />864 <br />Light <br />38 <br />950 <br />1368 <br />^HOBART/ <br />701 S Ridge Avenue, Troy, OH 45374 <br />1-888-4HOBART • www.hobartcorp.com <br />3272’ x 23'y.a" x 259/ia*__________ <br />94 | 124 | 254___ <br />1.8 KW <br />3272' x 23'5/i8* X 26,yi»' <br />120 1 146 275