My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2007
>
EP-07-301 thru EP-07-400
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:47:06 AM
Creation date
12/30/2015 9:55:27 AM
Metadata
Fields
Template:
Permits_Development
DocName
EP-07-349
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2007\EP-07-301 thru EP-07-400
Year2
2007
Supplemental fields
Applicant
ZABIH ZACA
Contracts
CrossReference
Date Entered
11/16/2007
Description
ENCROACHMENT PERMIT
DocCategory
Permit Applications (PA)
Notes
Owners
Parcel Address
FROM CHRISMAN RD. ALONG THE S/S OF 11th ST.
Primary Parcel
Type (2)
Tags
Permits_Development
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. Portland Cement: ASTM C150, Type I or 11, low-alkali. <br /> 2. Aggregate, General: _ <br /> a. ASTM C33, uniformly graded and clean. <br /> b. Do not use aggregate known to cause excessive shrinkage. <br /> 3. Aggregate, Coarse: crushed rock or washed gravel with minimum size — <br /> between 3/4-inch and 1-1/2 inches, and with a maximum size number 4. <br /> 4. Aggregate, Fine: natural washed sand of hard and durable particles _ <br /> varying from fine to particles passing a 3/8-inch screen, of which at least <br /> 12 percent shall pass a 50-mesh screen. <br /> 5. Water: clean and potable. <br /> 2.02 OTHER MATERIALS <br /> A. Provide other materials, not specifically described but required for a complete <br /> and proper installation, as selected by the Contractor. <br /> PART 3 - EXECUTION <br /> 3.01 EXISTING CONDITIONS _ <br /> A. Examine the areas and conditions under which the work of this Section will be <br /> performed. Correct conditions detrimental to timely and proper completion of the _ <br /> Work. Do not proceed until unsatisfactory conditions are corrected. <br /> 3.02 REINFORCING <br /> A. Per Section 03200. <br /> 3.03 EMBEDDED ITEMS <br /> A. Do not embed piping in structural concrete. <br /> B. Electrical Conduit: <br /> 1. Locate to maintain maximum strength of the structure. <br /> 2. Increase the thickness of the concrete if the outside diameter exceeds 30 <br /> percent of the thickness of the concrete. <br /> C. Set and secure bolts, inserts, and other required items in the precise locations <br /> needed so they are not displaced. <br /> D. Prior to concrete placement, assure the actual locations are noted on the as-built <br /> set of drawings. <br /> 3.04 FORMS <br /> July 2007 Division III-87 NEI Phase II Water and Sewer <br /> CIP Nos. 7468,7589, 7590 <br />
The URL can be used to link to this page
Your browser does not support the video tag.