B. All drawings shall be generated with a computer utilizing the AutoCAD 2005 or later <br /> drafting package. Standard preprinted drawings simply marked to indicate <br /> applicability to the Contract will not be acceptable. Drawings shall be prepared in a — <br /> professional manner and shall have borders and a title block identifying the project, <br /> system, drawing number, drawing title, AutoCAD file name, project engineer, date, <br /> revisions, and type of drawing. Drawings shall be no smaller than 11" x 17" and <br /> printed with a laserjet printer or plotted in ink on vellum.The lettering shall be legible <br /> and no smaller than 0.075 inch in height. Diagrams shall carry a uniform and <br /> coordinated set of wire colors,wire numbers, and terminal block numbers. The shop <br /> drawings shall include: <br /> 1. Electrical one or three line diagrams detailing all devices associated with the <br /> power distribution system. The following applicable information or data shall <br /> be shown on the one- or three- line diagram: location, size and amperage <br /> rating of bus; size and amperage rating of wire or cable; breaker ratings, <br /> number of poles, and frame sizes; fault interrupt ratings; ground size and _ <br /> connections; neutral size and connections; power fail and other protective <br /> devices;fuse size and type, starters; contactor size and overload range; motor <br /> full load amperage of submitted motor and horsepower; rating for <br /> miscellaneous loads; etc. Submit equipment motor voltage, phase and full <br /> load amps provided for this project for verification of accuracy of submitted one <br /> line drawings. _ <br /> 2. Elementary diagrams shall be provided for all relay logic, power supplies, LLC <br /> 1/0 and other wiring. All elementary diagrams shall be drawn in JIC EMP/EGP <br /> format and standards similar to those shown on the E-series elementary <br /> diagrams showing ladder rung numbers and coil and contact cross referencing <br /> numbers. <br /> 3. Analog and digital LLC 1/0 wiring diagrams shall be provided showing the — <br /> wiring requirements for each instrument loop. Graphic symbols shall conform <br /> with ISA S5.4 drawing standards. A loop diagram shall be furnished for each <br /> analog and digital 1/0 process and all LLC 1/0 points. Format and detail for _ <br /> loop diagrams shall be similar to that shown on contract drawing "E" series <br /> Loop diagrams shall include the following as a minimum: <br /> a. The loop diagram shall be drawn with sufficient detail to express control — <br /> philosophy.The diagram shall show all components and accessories of <br /> the instrument loop, highlighting special safety and other requirements. <br /> These diagrams shall be arranged to emphasize device elements and <br /> their functions as an aid to understanding the operation of a system and <br /> for maintaining or troubleshooting that system. <br /> b. Analog and digital 1/0 shall be arranged on the diagram in the same <br /> order as the physical arrangement of the group terminations. All <br /> termination points on the diagram shall be shown with the actual <br /> equipment identification, device and relay terminal number or letter, and — <br /> 1/0 point P&ID English descriptor and tag name. <br /> C. Energy sources - electrical power, air supply, pneumatic and hydraulic _ <br /> fluid supply, designating voltage, current, pressure, etc. shall be shown <br /> in detail on the diagram. Input and output signals (e.g., 1-5 VDC, 4-20 <br /> mA DC, 3-15 psig, etc.), power and instrument supplies to devices (e.g. <br /> 120VAC, 24 VDC, 80 psig, etc.) shall be shown. <br /> Division III-175 NEI Phase II Water and Sewer <br /> July 2007 CIP Nos. 7468, 7589, 7590 <br />