My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2007
>
EP-07-301 thru EP-07-400
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:47:06 AM
Creation date
12/30/2015 9:55:27 AM
Metadata
Fields
Template:
Permits_Development
DocName
EP-07-349
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2007\EP-07-301 thru EP-07-400
Year2
2007
Supplemental fields
Applicant
ZABIH ZACA
Contracts
CrossReference
Date Entered
11/16/2007
Description
ENCROACHMENT PERMIT
DocCategory
Permit Applications (PA)
Notes
Owners
Parcel Address
FROM CHRISMAN RD. ALONG THE S/S OF 11th ST.
Primary Parcel
Type (2)
Tags
Permits_Development
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
h barrier pressure screw <br /> relays shall be standard industrial bladetype lt <br /> terminals. Provide IDEC Type RH, or approved equal. Two fo m C contacts <br /> (minimum) shall be provided on each relay. <br /> 3. The power fail relay (PFR) shall continuously monitor the three phases for <br /> power loss, low voltage, phase loss, and phase reversal. The power fail <br /> monitor shall have a drop-out voltage adjustment, an adjustable delay on <br /> make time delay (0.2 to 8.0 minutes) and a status indicating LED. Power fail <br /> relays shall be Diversified SLJ, Time Mark, or approved equal. <br /> 4. Time delay relays shall be solid state plug-in relays with a timer adjustable <br /> over the range 1 second to 10 minutes unless other ranges are indicated or <br /> required. Provide LED timer energized indicator lamp. Sockets for plug-in _ <br /> timers shall be standard industrial type with barriered pressure screw <br /> terminals. Time delay relays shall be IDEC RTE, or approved equal. <br /> 5. Intrinsic safe relay (ISR) shall be Warrick Series 17AIEO operating from -.- <br /> 120VAC power, no equal. ISR shall have latch and un-latch inputs for use <br /> with a two float control system for differential level control. Sensitivity shall be <br /> 10,000 ohms. ISR shall be rated for Class 1, Division 2 sewage wetwell <br /> applications. <br /> D. Indicating Lights <br /> 1. Indicating Lights for general purpose applications shall be water and oil tight <br /> as defined by NEMA 4X, corrosion resistant as defined by NEMA ICS <br /> 6-110.58, U.L. listed, High intensity multi-chip LEDs,full voltage(unless shown <br /> otherwise), standard 30 mm diameter, with round plastic lens and miniature <br /> bayonet lamp base. Indication lights shall be Allen-Bradley 800H,or approved <br /> equal. <br /> 2. Manufacturer's standard size legend plates shall be provided and engraved to <br /> specify each light's function. The legend plate color shall be black. <br /> 3. Indicating light type and color of lens shall be as shown on the Drawings or — <br /> specified in the Contract documents. Lamp color will be as follows: <br /> a. Open/On Red — <br /> b. Closed/Off Green <br /> C. Alarm Amber _ <br /> d. Power On White <br /> E. Terminal Blocks — <br /> 1. General <br /> a. Each terminal block shall have a unique identifying alphanumeric code. <br /> Terminal numbers shall be assigned starting lowest number at one end, <br /> incrementing in sequence top to bottom or left to right (i.e., 1,2,3,4....). <br /> b. Numbers shall be assigned to all blocks except grounding blocks. Fuse <br /> blocks shall be assigned unique tag numbers such as FU1, FU2. No two <br /> fuses in a common enclosure shall be assigned the same tag number. <br /> Fuse blocks shall also be provided with markers identifying the current <br /> rating of the fuse. <br /> Division III-191 NEI Phase II Water and Sewer <br /> July 2007 C I P Nos.7468, 7589, 7590 <br />
The URL can be used to link to this page
Your browser does not support the video tag.