My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2007
>
EP-07-301 thru EP-07-400
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:47:06 AM
Creation date
12/30/2015 9:55:27 AM
Metadata
Fields
Template:
Permits_Development
DocName
EP-07-349
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2007\EP-07-301 thru EP-07-400
Year2
2007
Supplemental fields
Applicant
ZABIH ZACA
Contracts
CrossReference
Date Entered
11/16/2007
Description
ENCROACHMENT PERMIT
DocCategory
Permit Applications (PA)
Notes
Owners
Parcel Address
FROM CHRISMAN RD. ALONG THE S/S OF 11th ST.
Primary Parcel
Type (2)
Tags
Permits_Development
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Operator Interface (OI), the level logic controller (LLC), and LLC 1/0 modules in the <br /> control panels. <br /> 1. The UPS shall be on line system which provides continuous, no break power <br /> during complete blackouts or momentary interruptions. The UPS shall not <br /> utilize a ferroresonant transformer. The UPS shall provide +/- 3% load <br /> regulation while producing computer grade powerwith less than 5%THD.The -- <br /> UPS shall be rated to provide a minimum of VA output shown on Contract <br /> drawings at 120 VAC at an efficiency of 95%. <br /> 2. Mount UPS in control compartment and provide all necessary power wiring. <br /> Plug cords and receptacles shall be provided so that the UPS can be readily <br /> bypassed with power being obtained directly from the panelboard. <br /> 3. Submit load calculations of all connected 120 VAC loads showing UPS is <br /> adequately sized. <br /> 4. The UPS shall be an American Power Conversion (APC) Smart-Slot, or - <br /> approved equal. <br /> D. Miscellaneous Devices -- <br /> 1. RFI filters to be for power line radio frequency protection, CORCOM VK series <br /> or approved equal. _ <br /> 2. Analog 4-20 mA signals on wiring to all field instruments shall have surge <br /> protection terminals installed at panel originating loop power. Surge protection <br /> terminal blocks shall be fused and limit maximum working voltage to 32 VDC <br /> and rated for 50 mA. Loop surge protection terminal blocks to be MTL, or <br /> approved equal. <br /> 3. Data wiring (wiring in "D" Series conduits) between communication devices <br /> shall be protected on both ends by fused terminal surge protectors rated for <br /> use with data signal. Data terminal surge protectors shall be MTL or approved <br /> equal. — <br /> 4. DC Power Supplies <br /> a. DC power supplies to be linear type non-switching VDC, quantity and <br /> sizes per drawings, Power One International Series Linear, Sola, or <br /> approved equal. <br /> 5. Each isolator shall provide complete isolation of the 4-20 mA output signal _ <br /> from the input signal and isolator power supply. Each isolator shall have all <br /> solid state circuitry mounted in a plug-in module. The 4-20 mA output signal <br /> shall be capable of driving a 600 ohm load. Accuracy shall be +/- 0.25% of <br /> span. The isolator shall be powered as shown on Contract Drawings. Each <br /> isolator shall have a seven year warranty. The isolators shall be as <br /> manufactured by AGM Electronics, Action Instruments, or approved equal. <br /> at 10 <br /> 6. Alarm horn shall be Electro-be dust ti ht andal tion type poweredpromu 11ng 99 20VAC BAlarm <br /> feet (minimum). Horn shall 9 <br /> horn shall have an Operating Temperature from -35 to 150° F. Alarm horn <br /> shall be Federal Signal Corporation, Model # 350, 120 VAC or approved <br /> equal. <br /> E. Radio System <br /> Division III-201 NEI Phase II Water and Sewer <br /> July 2007 CIP Nos. 7468, 7589, 7590 <br />
The URL can be used to link to this page
Your browser does not support the video tag.