My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2007
>
EP-07-301 thru EP-07-400
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:47:06 AM
Creation date
12/30/2015 9:55:27 AM
Metadata
Fields
Template:
Permits_Development
DocName
EP-07-349
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2007\EP-07-301 thru EP-07-400
Year2
2007
Supplemental fields
Applicant
ZABIH ZACA
Contracts
CrossReference
Date Entered
11/16/2007
Description
ENCROACHMENT PERMIT
DocCategory
Permit Applications (PA)
Notes
Owners
Parcel Address
FROM CHRISMAN RD. ALONG THE S/S OF 11th ST.
Primary Parcel
Type (2)
Tags
Permits_Development
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Division III — Section 15100, "Piping Systems", Section 2.03 B, "Fittings", second <br /> sentence shall be modified to say, "All fittings shall be ductile iron. Flanged <br /> fittings shall be manufactured in accordance with AWWA C110 (ANSI A21.10). <br /> Mechanical Joint fittings shall be manufactured in accordance with AWWA <br /> C110 or AWWA C153." <br /> ITEM NO. 15 <br /> Division III — Section 15100, "Piping Systems", Section 2.03 C2, "Pipe Type A-2, <br /> Buried Pipe" —Add the following paragraph to the end of this section. <br /> Restrained joints are only required where shown on the plans. Where <br /> restrained joints are not required, thrust blocks, tie downs, or restrained <br /> joints for vertical bends shall be provided. <br /> ITEM NO. 16 <br /> Division III — Section 15100, "Piping Systems", Section 2.05 C, "Bolts Nuts, <br /> Washers, and Gaskets", first paragraph shall be modified to require Type 316 <br /> stainless steel. <br /> ITEM NO. 17 <br /> Division III — Section 15100, "Piping Systems", Section 2.08 A, "Metalic Flexible <br /> Couplings and Flange Adapters" - The last paragraph, second sentence shall <br /> read, "Bolts and nuts for buried flanges, tie rods, and fittings shall be Type 304 <br /> stainless steel. Mechanical joint fittings shall use manufacturer's supplied <br /> standard bolts and nuts." <br /> ITEM NO. 18 <br /> Attachment C-- Geotechnical Engineering Report, Figure 4 was missing from the <br /> Specifications. The missing page is to be included is provided as an attachment <br /> to this addendum. <br /> ITEM NO. 19 <br /> Plan Sheet G05, Item No. 39 shall be modified to read: <br /> 39. Proper Traffic Control shall be maintained at all times during <br /> construction in accordance with the City and County's adopted <br /> Traffic Manual, and guidelines stipulated in the California Manual <br /> of Uniform Traffic Control Devices (CA MUTCD). Contractor shall <br /> submit traffic control plans to the City and County for review at the <br /> pre-construction meeting and obtain acceptance before starting <br /> work. <br /> ITEM NO. 20 <br /> Plan Sheet C18, C19, C24, C25, C107 and C113 shall be substituted with the <br /> attached sheets. Revisions are noted with bubbles and generally include the <br /> Addendum No. 3 -August 24, 2007 <br /> Northeast Industrial Phase II Water and Sewer Project <br /> CIP 7468, 7589, 7590 <br />