My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-352
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2007
>
EP-07-301 thru EP-07-400
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-352
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:47:10 AM
Creation date
12/30/2015 9:44:57 AM
Metadata
Fields
Template:
Permits_Development
DocName
EP-07-352
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2007\EP-07-301 thru EP-07-400
Year2
2007
Supplemental fields
Applicant
RICHARD A. HEAP ELECT. CONT.
Contracts
CrossReference
Date Entered
11/15/2007
Description
ENCROACHMENT PERMIT
DocCategory
Permit Applications (PA)
Notes
Owners
Parcel Address
INTERSECTION OF FRENCH CAMP RD. & I-5
Primary Parcel
Type (2)
Tags
Permits_Development
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
215
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
The third subparagraph of the twenty-third paragraph in Section 86-2.05C, "Installation," of the Standard Specifications <br /> is amended to read: <br /> • Precast concrete conduit cradles shall conform to the dimensions shown on the plans and shall be constructed of <br /> minor concrete and commercial quality welded wire fabric. Minor concrete shall conform to the provisions in Section 90-10, <br /> "Minor Concrete," and shall contain not less than 350 kilograms of cementitious material per cubic meter. The cradles shall <br /> be moist cured for not less than 3 days. <br /> The seventh subparagraph of the twenty-third paragraph in Section 86-2.05C, "Installation," of the Standard <br /> Specifications is amended to read: <br /> • The space around conduits through bridge abutment walls shall be filled with mortar conforming to the provisions in <br /> Section 51-1.135,"Mortar,"except that the proportion of cementitious material to sand shall be 1:3. <br /> The fifth paragraph in Section 86-2.07,"Traffic Pull Boxes,"of the Standard Specifications is amended to read: <br /> • Concrete placed around and under traffic pull boxes as shown on the plans shall be minor concrete conforming to <br /> the provisions in Section 90-10,"Minor Concrete." <br /> The traffic signal controller cabinet requirement in the table in Section 86-2.08A, "Conductor Identification," of the <br /> Standard Specifications is amended to read: <br /> Traffic Signal Ungrounded Circuit Conductor Blk None CON-1 1 6 <br /> Controller Cabinet I Grounded Circuit Conductor Wht None CON-2 1 6 <br /> The second paragraph of Section 86-2.08B,"Multiple Circuit Conductors," of the Standard Specifications is amended to <br /> read by the following 2 paragraphs: <br /> • At any point, the minimum insulation thickness of any Type USE, RHH, or RHW insulation shall be 1.0 mm for <br /> conductor sizes No. 14 to No. 10,inclusive;and 1.3 mm for No. 8 to No.2,inclusive. <br /> • At any point,the minimum insulation thickness of any Type THW or TW wires shall be 0.7 mm for conductor sizes <br /> No. 14 to No. 10,inclusive; 1.0 nun for No. 8;and 1.4 mm for No.6 to No.2,inclusive. <br /> The sixth and seventh paragraphs of 86-2.12,"Wood Poles,"of the Standard Specifications are amended to read: <br /> • After fabrication, wood poles shall be pressure treated in conformance with the provisions in Section 58, <br /> "Preservative Treatment of Lumber, Timber and Piling," and AWPA Use Category System: UC413, Commodity <br /> Specification D. <br /> • Wood poles, when specified in the special provisions to be painted, shall be treated with waterborne wood <br /> preservatives. <br /> The first paragraph of Section 86-2.15,"Galvanizing,"of the Standard Specifications is amended to read: <br /> • Galvanizing shall be in conformance with the provisions in Section 75-1.05, "Galvanizing," except that cabinets <br /> may be constructed of material galvanized prior to fabrication in conformance with the requirements in ASTM Designation: <br /> A 653/653M,Coating Designation G 90,in which case all cut or damaged edges shall be painted with at least 2 applications <br /> of approved unthinned zinc-rich primer(organic vehicle type) conforming to the provisions in Section 91, "Paint." Aerosol <br /> cans shall not be used. Other types of protective coating must be approved by the Engineer prior to installation. <br /> Item B of the thirteenth paragraph of Section 86-2.16,"Painting,"of the Standard Specifications is amended to read: <br /> B. Salt Spray Resistance-The undercutting of the film of the coating system shall not exceed 3 mm average,from lines <br /> scored diagonally and deep enough to expose the base metal, after 336 hours exposure in a salt spray cabinet in <br /> conformance with the requirements in ASTM Designation: B 117. <br /> The first paragraph of Section 86-4.01,"Vehicle Signal Faces," of the Standard Specifications is amended to read: <br /> • Each vehicle signal face shall be of the adjustable type conforming to the requirements in Institute of Transportation <br /> Engineers(ITE)Publication: ST-017B,"Vehicle Traffic Control Signal Heads." <br /> Contract No. 10-OM7104 <br /> 66 <br />
The URL can be used to link to this page
Your browser does not support the video tag.