Laserfiche WebLink
Information on cross-referencing California sign codes with the Federal MUTCD sign codes is available at: <br /> http://www.dot.ca.gov/hq/traffops/signtech/signdeVspecs.htm <br /> Temporary or permanent signs shall be free from blemishes that may affect the serviceability and detract from the <br /> general sign color and appearance when viewing during daytime and nighttime from a distance of 8 m. The face of each <br /> finished sign shall be uniform,flat, smooth,and free of defects,scratches,wrinkles,gel,hard spots,streaks,extrusion marks, <br /> and air bubbles. The front,back,and edges of the sign panels shall be free of router chatter marks,burns, sharp edges,loose <br /> rivets,delaminated skins,excessive adhesive over spray and aluminum marks. <br /> QUALITY CONTROL FOR SIGNS <br /> The requirements of"Quality Control for Signs"in this section shall not apply to construction area signs. <br /> No later than 14 days before sign fabrication,the Contractor shall submit a written copy of the quality control plan for <br /> signs to the Engineer for review. The Engineer will have 10 days to review the quality control plan. Sign fabrication shall <br /> not begin until the Engineer approves the Contractor's quality control plan in writing. The Contractor shall submit to the <br /> Engineer at least 3 copies of the approved quality control plan. The quality control plan shall include,but not be limited to <br /> the following requirements: <br /> A. Identification of the party responsible for quality control of signs, <br /> B. Basis of acceptance for incoming raw materials at the fabrication facility, <br /> C. Type,method and frequency of quality control testing at the fabrication facility, <br /> D. List (by manufacturer and product name) of process colors, protective overlay film, retroreflective sheering and <br /> black non-reflective film, <br /> E. Recommended cleaning procedure for each product,and <br /> F. Method of packaging,transport and storage for signs. <br /> No legend shall be installed at the project site. Legend shall include letters,numerals,tildes,bars,arrows,route shields, <br /> symbols,logos,borders,artwork,and miscellaneous characters. The style,font,size,and spacing of the legend shall conform <br /> to the Standard Alphabets published in the FHWA Standard Highway Signs Book. The legend shall be oriented in the same <br /> direction in accordance with the manufacturer's orientation marks found on the retroreflective sheeting. <br /> On multiple panel signs,legend shall be placed across joints without affecting the size,shape,spacing,and appearance of <br /> the legend. Background and legend shall be wrapped around interior edges of formed panel signs as shown on plans to <br /> prevent delamination. <br /> the lower right side of the back of each sign where the notation will not be <br /> The following notation shall be placed on <br /> blocked by the sign post or frame: <br /> A. PROPERTY OF STATE OF CALIFORNIA, <br /> B. Name of the sign manufacturer, <br /> C. Month and year of fabrication, <br /> D. Type of retroreflective sheeting,and <br /> E. Manufacturer's identification and lot number of retroreflective sheeting. <br /> The above notation shall be applied directly to the aluminum sign panels in 6-mm upper case letters and numerals by <br /> die-stamp and applied by similar method to the fiberglass reinforced plastic signs. Painting, screening, or engraving the <br /> notation will not be allowed. The notation shall be applied without damaging the finish of the sign. <br /> Signs with a protective overlay film shall be marked with a dot of 10 mm diameter. The dot placed on white border shall <br /> be black,while the dot placed on black border shall be white. The dot shall be placed on the lower border of the sign before <br /> application of the protective overlay film and shall not be placed over the legend and bolt holes. The application method and <br /> exact location of the dot shall be determined by the manufacturer of the signs. <br /> For sign panels that have a minor dimension of 1220 mm or less, no splice will be allowed in the retroreflective sheet <br /> except for the splice produced during the manufacturing of the retroreflective sheeting. For sign panels that have a minor <br /> dimension greater than 1220 mm,only one horizontal splice will be allowed in the retroreflective sheeting. <br /> Unless specified by the manufacturer of the retroreflective sheering, splices in retroreflective sheering shall overlap by a <br /> minimum of 25 mm. Splices shall not be placed within 50 mm from edges of the panels. Except at the horizontal borders, <br /> the splices shall overlap in the direction from top to bottom of the sign to prevent moisture penetration. The retroreflective <br /> sheering at the overlap shall not exhibit a color difference under the incident and reflected light. <br /> Signs exhibiting a significant color difference between daytime and nighttime shall be replaced immediately. <br /> Contract No. 10-OM7104 <br /> 174 <br />