Laserfiche WebLink
• Ribbed sheet metal for box beam-closed truss sign structures shall be fabricated from galvanized sheet steel <br /> conforming to the requirements in ASTM Designation: A 653/A 653M,Designation SS,Grade 33[230]. Sheet metal panels <br /> shall be G 165 coating designation in conformance with the requirements in ASTM Designation: A 653/A 653M. <br /> Section 56-1.02F,"Steel Walkway Gratings,"of the Standard Specifications is amended to read: <br /> 56-1.02F Steel Walkway Gratings <br /> • Steel walkway gratings shall be furnished and installed in conformance with the details shown on the plans and the <br /> following provisions: <br /> A. Gratings shall be the standard product of an established grating manufacturer. <br /> B. Material for gratings shall be structural steel conforming to the requirements in ASTM Designation: A 1011/A <br /> 1011 M,Designation CS,Type B. <br /> C. For welded type gratings, each joint shall be full resistance welded under pressure,to provide a sound, completely <br /> beaded joint. <br /> D. For mechanically locked gratings, the method of fabrication and interlocking of the members shall be approved by <br /> the Engineer,and the fabricated grating shall be equal in strength to the welded type. <br /> E. Gratings shall be accurately fabricated and free from warps, twists, or other defects affecting their appearance or <br /> serviceability. Ends of all rectangular panels shall be square. The tops of the bearing bars and cross members shall <br /> be in the same plane. Gratings distorted by the galvanizing process shall be straightened. <br /> The fifth paragraph in Section 56-1.03,"Fabrication,"of the Standard Specifications is amended to read: <br /> • Clips, eyes, or removable brackets shall be affixed to all signs and all posts and shall be used to secure the sign <br /> during shipping and for lifting and moving during erection as necessary to prevent damage to the finished galvanized or <br /> painted surfaces. Brackets on tubular sign structures shall be removed after erection. Details of the devices shall be shown <br /> on the working drawings. <br /> The sixth through the thirteenth paragraphs in Section 56-1.03, "Fabrication," of the Standard Specifications are <br /> amended to read: <br /> • High-strength bolted connections, where shown on the plans, shall conform to the provisions in Section 55-3.14, <br /> "Bolted Connections," except that only fastener assemblies consisting of a high-strength bolt, nut, hardened washer, and <br /> direct tension indicator shall be used. <br /> • High-strength fastener assemblies, and any other bolts, nuts, and washers attached to sign structures shall be zinc- <br /> coated by the mechanical deposition process. <br /> • Nuts for high-strength bolts designated as snug-tight shall not be lubricated. <br /> • An alternating snugging and tensioning pattern for anchor bolts and high-strength bolted splices shall be used. Once <br /> tensioned,high-strength fastener components and direct tension indicators shall not be reused. <br /> • For bolt diameters less than 10 mm, the diameter of the bolt hole shall be not more than 0.80-mm larger than the <br /> nominal bolt diameter. For bolt diameters greater than or equal to 10 mm, the diameter of the bolt hole shall be not more <br /> than 1.6 mm larger than the nominal bolt diameter. <br /> • Sign structures shall be fabricated into the largest practical sections prior to galvanizing. <br /> • Ribbed sheet metal panels for box beam closed truss sign structures shall be fastened to the truss members by cap <br /> screws or bolts as shown on the plans,or by 4.76 mm stainless steel blind rivets conforming to Industrial Fasteners Institute, <br /> Standard IFI-114, Grade 51. The outside diameter of the large flange rivet head shall be not less than 15.88 mm in diameter. <br /> Web splices in ribbed sheet metal panels may be made with similar type blind rivets of a size suitable for the thickness of <br /> material being connected. <br /> • Spalling or chipping of concrete structures shall be repaired by the Contractor at the Contractor's expense. <br /> • Overhead sign supports shall have an aluminum identification plate permanently attached near the base, adjacent to <br /> the traffic side on one of the vertical posts, using either stainless steel rivets or stainless steel screws. As a minimum, the <br /> information on the plate shall include the name of the manufacturer,the date of manufacture and the contract number. <br /> The fifth paragraph of Section 56-2.02B, "Wood Posts,"of the Standard Specifications is amended to read: <br /> • Douglas fir and Hem-Fir posts shall be treated in conformance with the provisions in Section 58, "Preservative <br /> Treatment of Lumber, Timber and Piling," and in conformance with AWPA Use Category System: UC4A, Commodity <br /> Specification A. Posts shall be incised and the minimum retention of preservative shall be as specified in AWPA Standards. <br /> Contract No. 10-OM7104 <br /> 47 <br />