My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2001501 thru PS-2002000_ - PS-2001599
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2020
>
PS-2001501 thru PS-2002000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2001501 thru PS-2002000_ - PS-2001599
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2023 9:32:40 AM
Creation date
1/23/2023 9:31:21 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2001599
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2020
Notes2
N/S E. Peltier Rd. 70' W/O St. Rt. 99 Frntg Rd.
Address
12687 S. Manthey Rd., Lathrop,CA 95330
Application
Comcast/SEFNCO
Type
TCP
Supplemental fields
Cross Ref
PWP7110005
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET: CD-0 <br />THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />GENERAL NOTES <br />•CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE OF <br />WORK COMMENCING. <br />•CONTRACTOR SHALL NOTIFY BUSINESS ESTABLISHMENTS/OWNERS AFFECTED BY THE WORK <br />AT LEAST 72 HOURS IN ADVANCE OF CONSTRUCTION. <br />•ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS. <br />•CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 HOURS <br />(AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION BY CALLING (800) <br />227-2600. <br />•CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OF <br />CONSTRUCTION. ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE. <br />•CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES PRIOR <br />TO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON PLANS ARE APPROXIMATE, <br />CONTRACTOR MUST VERIFY. <br />•CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITH <br />REGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVING <br />JURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE STATE OF <br />CALIFORNIA PUBLIC UTILITY COMMISSION (CPUC), THE STATE OF CALIFORNIA <br />OCCUPATIONAL SAFETY AND HEALTH ACT (CAL OSHA), THE COUNTY AND THE CITY. <br />•CONTRACTOR SHALL KEEP A COPY OF APPROVED PLAN(S) AND PERMIT(S) AT THE JOB SITE <br />AT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY/COUNTY AND/OR <br />LAW ENFORCEMENT UPON REQUEST. <br />•CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE WITH <br />THE CITY/COUNTY AND STATE OF CALIFORNIA STANDARD PLANS AND SPECIFICATIONS, AND <br />CURRENT CALIFORNIA DEPARTMENT OF TRANSPORTATION “MANUAL OF TRAFFIC CONTROLS <br />AND MAINTENANCE OF HAZARD ZONE” AND “MANUAL OF WARNING SIGNS, LIGHTS AND <br />DEVICES” FOR USE IN PERFORMANCE OF WORK UPON HIGHWAYS. FLASHING ARROW SIGNS <br />SHALL BE REQUIRED FOR ALL LANE CLOSURES. <br />•ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TO INSPECTION BY THE CITY/COUNTY <br />ENGINEER AND/OR AN AUTHORIZED AGENT OF COMCAST. <br />•CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED SHALL <br />BE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO REPLACING EXISTING <br />STRIPING AND REMOVING UNNECESSARY “USA” MARKINGS. <br />•CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISE <br />APPROVED IN WRITING BY THE “CITY/COUNTY ENGINEER.” <br />BORE PIT <br />WATER MANHOLE <br />UNIDENTIFIED MANHOLE <br />GAS METER <br />WATER METER <br />ELECTRIC MANHOLE <br />SEWER CLEAN OUT <br />SANITARY SEWER MANHOLE <br />STORM DRAIN MANHOLE <br />CATCH BASIN <br />GAS/WATER VALVE <br />TREE/BUSHES <br />EXISTING POLE <br />EXISTING COMCAST PEDESTAL <br />POTHOLE <br />EXISTING IRRIGATION VAULT <br />EXISTING COMCAST VAULT <br />EXISTING UTILITY VAULT/PEDESTAL <br />MONUMENT <br />FIRE HYDRANT <br />TRAFFIC SIGNAL COMBINATION <br />STREET LIGHT <br />TRANSFORMER <br />NEW COMCAST LOW PROFILE <br />NEW COMCAST PEDESTAL <br />NEW COMCAST VAULT <br />POWER SUPPLY W/ METER <br />NEW COMCAST POWER SUPPLY <br />NEW RISER ATTACHED TO POLE <br />TV <br />T <br />E <br />G <br />SS <br />SD <br />W <br />ROADWAY CENTER LINE <br />EXISTING COMCAST ROUTE <br />EXISTING FENCELINE <br />PROPOSED TRENCH/BORE ROUTE <br />EXISTING WATER LINE <br />EXISTING STORM DRAIN <br />EXISTING SANITARY SEWER <br />IRR EXISTING IRRIGATION SYSTEM <br />EXISTING GAS SYSTEM <br />EXISTING ELECTRICAL SYSTEM <br />EXISTING TELEPHONE SYSTEM <br />PROPERTY LINE <br />TV EXISTING TV SYSTEM <br />JT EXISTING JOINT TRENCH <br />COMCAST <br />C/L <br />(E) <br />FOC <br />MIN <br />MAX <br />(N) <br />BOW <br />CNDT <br />(T) <br />DWY <br />MAXIMUM <br />CENTER LINE <br />COMCAST <br />EXISTING <br />FACE OF CURB <br />MINIMUM <br />NEW <br />DRIVEWAY <br />TEMPORARY <br />CONDUIT <br />BACK OF WALK <br />PUE <br />W <br />E <br />G <br />R/W <br />PL <br />SS <br />SD <br />T <br />EOP <br />LOG <br />EXISTING ELECTRIC <br />LIP OF GUTTER <br />RIGHT OF WAY <br />PUBLIC UTILITY EASEMENT <br />EXISTING STORM DRAIN <br />EXISTING WATER <br />EXISTING TELEPHONE <br />PROPERTY LINE <br />EXISTING SANITARY SEWER <br />EXISTING GAS <br />EDGE OF PAVEMENT <br />ABBREVIATIONS <br />LINETYPES <br />PROPOSED OVERLASH ROUTE <br />PROPOSED OVERPULL ROUTE <br />RIGHT OF WAY LINE <br />SYMBOLS <br />DESIGN: CITYRISE <br />DRAWN BY: <br />APPROVED: <br />APPROVED: <br />APPROVED: <br />LEGEND, GENERAL NOTES <br />NODE: <br />REV DESCRIPTION DATE <br />JOB#: JB347734 <br />CONSTRUCTION TYPE: Aerial <br />23265 CA-99 <br />SYSTEM: County of San Joaquin
The URL can be used to link to this page
Your browser does not support the video tag.