My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2002001 thru PS-2002500_ - PS-2002480
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2020
>
PS-2002001 thru PS-2002500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2020_PS-2002001 thru PS-2002500_ - PS-2002480
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2023 9:54:08 AM
Creation date
1/26/2023 9:50:18 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2002480
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2020
Notes2
Lower Sacramento Rd. @ Bear Creek Slough and Ranier Ave@ Stockton City Limits
Address
10096 Ahart Rd., Oroville,CA 95966
Application
Frank Medina
Type
Guardrail Replacements
Supplemental fields
Cross Ref
PWP110005
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
3 <br /> <br />General Information (continued) <br /> <br />The MSKT is a tangent redirective and gating single-sided W-Beam terminal with a length-of-need <br />(LON) point at post #3. The MSKT uses 8" or 12" offset blocks and is designed to be attached to <br />strong post W-Beam guardrail systems (using 8" or 12" offset blocks) that have been tested and <br />accepted under the MASH crash testing criteria. If the MSKT is intended to attach to a rigid barrier, <br />a transition to gradually increase the stiffness in the W-Beam shall be required. The terminal would <br />have a length of 50'-0" for TL-3. Check the State standard sheets or contract plans to see which <br />option is approved in your State. <br /> <br />The MSKT is a tangent terminal and no offset is required. However to avoid nuisance impacts, a <br />straight flare offset of 1-ft but no more than 2-ft (25:1 maximum) is recommended over a 50 ft length. <br />For TL-2 applications, the flare rate is the same and the allowable offset is variable anywhere <br />between zero and 1-ft over a 25 ft length. Design, selection & placement of the MSKT system shall <br />conform to the AASHTO Roadside Design Guide and the details shown on the contract plans. The <br />assembly of the MSKT shall be in accordance with the recommendations of Road Systems, Inc. <br /> <br /> <br />NOTE: Anywhere a W6x9# x 6'-0" standard guardrail post is mentioned throughout this <br />manual, a W6x8.5# x 6'-0" standard guardrail post is equivalent and is permitted. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />Impact Head delineated <br />with Object Marker
The URL can be used to link to this page
Your browser does not support the video tag.