My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2021_PS-2102001 thru PS-2102500_ - PS-2102021
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2021
>
PS-2102001 thru PS-2102500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2021_PS-2102001 thru PS-2102500_ - PS-2102021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2023 10:21:38 AM
Creation date
5/1/2023 10:10:33 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2102021
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2021
Notes2
Manthey Road S/O Yettner Road, Stockton
Address
1325 J Street, Sacramento,CA 95814
Application
US Army Corps of Engineers
Type
Road Widening,Driveways & Turn Lanes
Supplemental fields
Cross Ref
PWP760036
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
F <br />E <br />D <br />C <br />B <br />A <br />O <br />N <br />S o <br />17 <br />0 <br />a <br />a <br />t= <br />1 2 3 4 5 6 7 8 9 10 <br />0 SOLICITATION SET 15 OCT 21 <br />NO REVISIONS DATE <br />EXISTING CURB TO BE <br />DEMOLISHED, SEE <br />CIVIL PLANS <br />ADJUST PLANTING TO <br />NEW CURB LOCATIONS <br />NEW CURB MEDIAN <br />PER OFF—SITE <br />IMPROVEMENT PLANS, <br />SEE SHEET CS401 <br />EXISTING CURB TO BE— <br />DEMOLISHED, SEE <br />CIVIL PLANS TYP <br />ADJUST EXISTING SYSTEM <br />COMPONENTS TO NEW <br />CURB LOCATIONS <br />NEW CURB MEDIAN <br />PER OFF—SITE <br />IMPROVEMENT PLANS, <br />SEE SHEET CS401 <br />-------------- <br />f1UUVJl I LliIVIIIVV IV <br />NEW CURB LOCATIONS <br />Q <br />CL <br />0 <br />0 <br />J <br />PLANTING PLAN <br />1 <br />IRRIGATION PLAN <br />LANDSCAPE MATERIALS <br />KEY <br />ARCHITECTS/ENGINEERS: <br />TREES SPECIES <br />COMMON NAME <br />SIZE/NOTES <br />o PYRUS CALLERYANA'REDSPIRE' <br />REDSPIRE CALLERY PEAR <br />36" BOX <br />SHRUBS SPECIES <br />VM <br />VM <br />MAHONIAAQUIFOLIUM'COMPACTA' <br />VM <br />1 GAL <br />1 <br />IRRIGATION PLAN <br />LANDSCAPE MATERIALS <br />KEY <br />ARCHITECTS/ENGINEERS: <br />TREES SPECIES <br />COMMON NAME <br />SIZE/NOTES <br />o PYRUS CALLERYANA'REDSPIRE' <br />REDSPIRE CALLERY PEAR <br />36" BOX <br />SHRUBS SPECIES <br />COMMON NAME <br />SIZE/NOTES <br />MAHONIAAQUIFOLIUM'COMPACTA' <br />OREGON GRAPE <br />1 GAL <br />ROSA CALIFORNICA <br />CALIFORNIA WILD ROSE <br />1 GAL <br />GRASSES && GROUNDCOVERS <br />COMMON NAME <br />SIZE/NOTES <br />`+'+`+'+ ARCTOSTAPHYLOS EDMUNDSII'CARMEL SUR' <br />LITTLE SUR MANZANITA <br />1 GAL/TOC <br />COTONEASTER DAMMERI 'LOWFAST' <br />BEARBERRY COTONEASTER <br />1 GAL/TOC <br />SEED MIXES & SOD <br />40 <br />0.42 <br />NATIVE ORNAMENTAL FESCUE MIX <br />48LBS/AC <br />PROS-I2-PRS40-CV-MP2000-90 <br />vvvvvvvvvv HABITAT MIX W/FLOWERS <br />48LBS/AC <br />LANDSCAPE GENERAL NOTES <br />1. THE CONTRACTOR SHALL VERIFY THE LOCATION OF EXISTING AND PROPOSED SITE UTILITIES PRIOR TO THE <br />INSTALLATION OF PLANT MATERIAL, AND NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE (COR) OR <br />RESIDENT ENGINEER (RE) OF ANY CONFLICTS; SEE CIVIL <br />2. ALL PROPOSED TREES SHALL BE STAKED OUT IN THEIR APPROXIMATE LOCATION BY THE CONTRACTOR, AND <br />LOCATIONS OF THE STAKES ADJUSTED TO ACCOUNT FOR SUBSURFACE UTILITIES AND OTHER FIELD CONDITIONS; <br />FINAL LOCATIONS MUST BE APPROVED BY LANDSCAPE ARCHITECT (OR COR/RE) PRIOR TO THE DIGGING OF TREE <br />PITS AND THE DELIVERY OF MATERIALS FOR PLANTING <br />3. ALL GROUNDCOVER TO BE TRIANGULAR SPACED; SEE KEY FOR SPACING <br />4. CONTRACTOR SHALL REPLACE AND RESTORE AREAS NOT SCHEDULED FOR CONSTRUCTION TO THEIR ORIGINAL <br />CONDITION IF DISTURBED DURING CONSTRUCTION <br />5. CONTRACTOR SHALL PROVIDE WATERING DURING CONSTRUCTION AND MAINTENANCE/WARRANTY PERIOD <br />6. PERFORM WORK IN ACCORDANCE WITH THE AMERICAN ASSOCIATION OF NURSERYMEN STANDARDS <br />7. ALL PLANTERS WHERE TREES ARE PRESENT SHALL HAVE 24" DEEP ROOT BARRIER INSTALLED ADJACENT TO ALL <br />PAVED EDGES <br />8. PLANT MATERIALS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEYOND THE FINAL DATE OF ACCEPTANCE, <br />SEE SPECS <br />IRRIGATION <br />KEY <br />ARCHITECTS/ENGINEERS: <br />DiaWngThe <br />PrjedTitle <br />Mon Number <br />COMPONENT <br />BRAND (OR EQUAL) <br />MODEL <br />RADIUS <br />PSI <br />GPM NOTES <br />© <br />HUNTER <br />RZWS-18-50-CV <br />15-70 <br />0.50 2 PER TREE/1 PER SHRUB <br />NOSOApF <br />�,� �OTrq�c <br />HUNTER* <br />PROS-I2-PRS40-CV-MP1000-90 <br />8-15' <br />40 <br />0.21 <br />Building Number <br />HUNTER* <br />PROS- 12-PRS40-CV-MP1000-180 <br />8-15' <br />40 <br />0.42 <br />O <br />HUNTER <br />PROS-I2-PRS40-CV-MP2000-90 <br />13-21' <br />40 <br />C <br />HUNTER <br />PROS-12-PRS40-CV-MP2000-180 <br />13-21' <br />40 <br />Signa ure <br />Renewal Date <br />* N10/15/2021e * <br />P <br />F)l <br />NT9TFOF <br />E)— <br />HUNTER* <br />PROS-12-PRS40-CV-MP3000-180 <br />22-30' <br />40 <br />0.86 <br />*PROCURE TO REPLACE EXISTING COMPONENT WHERE SHOWN ON PLAN <br />IRRIGATION NOTES <br />1. CONTRACTOR SHALL VERIFY FIELD CONDITIONS BEFORE WORK BEGINS <br />2. IRRIGATION PLANS ARE DIAGRAMMATIC - ACTUAL LOCATION OF IRRIGATION IMPROVEMENTS SHALL BE INSTALLED IN <br />PLANTED AREAS AND TRENCHES ARE TO BE SHARED, WHERE FEASIBLE <br />3. LANDSCAPE CONTRACTOR TO CONFIRM UTILITY PLACEMENT PRIOR TO INSTALLING IRRIGATION SYSTEM TO AVOID <br />CONFLICTS. <br />KEY PLAN <br />PIAN <br />NORTH <br />0 10'-0" 20'-0" 40'-0" <br />CONSULTANTS: <br />CONSULTANT: <br />ARCHITECTS/ENGINEERS: <br />DiaWngThe <br />PrjedTitle <br />Mon Number <br />Project Numbs <br />Office of <br />MAIN ENTRY DRIVE <br />VA Livermore Realignment and <br />640 <br />640-423 <br />ARCHITECTURE/MECHANICALIELECTRICALI CIVIL SURVEYOR FIRE PROTECTION: <br />INTERIOR DESIGNI PLUMBING: <br />NOSOApF <br />�,� �OTrq�c <br />PLANTING AND IRRIGATION PLANS <br />Closure - Manthey Rd. Offsite and <br />Construction <br />Building Number <br />SECURITYISIGNAGE/ <br />COMMUNICATIONS/ MEDICAL <br />Onsite Revisions <br />GaynerEngineers Sandis Jensen Hughes Inc. <br />EQUIPMENT/ MASTER PUW 1133 Post Street 6369th Street 2950 Buskirk Avenue, She. 225 <br />and Facilities <br />LANDSCAPE/ San Francisco,CA 94109 Oakland, CA 94607 Walnut Creek,CA94597 <br />ENVIRONMENTAL <br />ASSESSMENT: STRUCTURAL: GEOTECHNICAL: COST ESTIMATING: <br />Signa ure <br />Renewal Date <br />* N10/15/2021e * <br />P <br />F)l <br />NT9TFOF <br />Location Stockton (French Camp) <br />San Joaquin County' CA <br />Diaivin number <br />9 <br />Management <br />Degankolb Engineers ance Group AECOM <br />HDR Architecture, Inc. 375 Beale Street Suite 500 4321iSWCoNett#200 3000alifomiaStreet, Suite 400 <br />Suite 1500 San Francisca, CA 94105 Portland, OR 97239 San Francisco, CA 94104 <br />201 Fr arf Francisco, <br />Francisco, <br />CA��FOR�\ <br />Date Checked by Diawn <br />LP100 <br />`//� U.S. Department <br />40of <br />CA 94111 <br />San , CA 9 <br />15 OCT 2021 AC AYS <br />v/-� Veterans Affairs <br />�4 <br />3 <br />4 <br />b', <br />6 <br />7 <br />8 <br />9 <br />iU] <br />E <br />�y <br />B <br />A <br />
The URL can be used to link to this page
Your browser does not support the video tag.