Laserfiche WebLink
LINETYPES <br />GENERAL NOTES: <br />FIBER PLACEMENT NOTES: <br />PROPOSED BORE ROUTE <br />PROPOSED TRENCH ROUTE <br />1. <br />ALL VAULTS/ HANDHOLES TO BE EQUIPPED WITH SECURITY LIDS WITH LOCKING BOLTS. <br />1. <br />CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 <br />CATV <br />NEW AERIAL ROUTE <br />HOURS PRIOR TO CONSTRUCTION ACTIVITY <br />TV <br />OVERPULL/EXISTING COMCAST CONDUIT <br />2. <br />GROUND RESTORATION/RIGHT-OF-WAY SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION. <br />SEE LOCAL DIRECTORY FOR CONTACT TELEPHONE NUMBER OF <br />T <br />EXISTING TELEPHONE SYSTEM <br />LOCAL CALL BEFORE YOU DIG AGENCY. <br />3. <br />ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM OF 36'' RADIUS UNLESS <br />E <br />EXISTING ELECTRICAL SYSTEM <br />SPECIFIED OTHERWISE. <br />2. <br />CONTRACTOR SHALL RECORD SEQUENCE# OF FIBER CABLE AT <br />G <br />EXISTING GAS SYSTEM <br />EVERY WORK POLE, MANHOLE, FIBRE STORAGE LOOP <br />4. <br />BURIED FIBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OF ALL ROAD CROSSINGS, <br />AND TAIL LOCATION. CONTRACTOR TO PROVIDE PROJECT <br />Tv <br />EXISTING TV SYSTEM <br />AT CULVERTS, DITCHESAND IN A STRAIGHT LINE OF SIGHT SPACING OFAPPROXIMATELY 500 FEET. <br />MANAGER WITH SEQUENCE NUMBERS AT PROJECT <br />IRR <br />EXISTING IRRIGATION SYSTEM <br />COMPLETION. <br />5. <br />DEVIATIONS FROM THE ENGINEERED ROUTE REQUIRESA PROJECT MANAGER AND RIGHT-OF-WAY <br />JT <br />EXISTING JOINT TRENCH <br />OWNER OF CARETAKER APPROVAL PRIOR TO CONSTRUCTION. <br />3. <br />SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHALL BE <br />DETERMINED ON CONSTRUCTION DRAWINGS, HOWEVER, <br />ss <br />EXISTING SANITARY SEWER <br />6. <br />WHERE PERMITS FROM STATE, COUNTY, CITY, RAILROAD OR GOVERNMENT AGENCIES ARE <br />REEL LENGTHS OF FIVE HUNDRED FEET (500') OR LESSON LARGE <br />SD <br />EXISTING STORM DRAIN <br />REQUIRED, ALL WORK PERFORMED WILL COMPLY WITH THESE AGENCIES STANDARD <br />COUNT FIBER OR THREE HUNDRED (300') OR LESS <br />SPECIFICATIONS. <br />ON SMALL COUNT FIBER ARE DIFFICULT TO USE AND SHOULD BE <br />W <br />EXISTING WATER LINE <br />PLACED AS FSUS, NOT CUTAND RETURNED. <br />x x x <br />EXISTING FENCELINE <br />7. <br />THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN WORK WILLBEGIN ON <br />BUILDING. CONTRACTOR TO COORDINATE ROOM ACCESSAND WORKSTARTAND STOP TIMES <br />4. <br />FIBEROPTIC IDENTIFICATION TAGS SHALL BE PLACEDAT EVERY <br />ROADWAY CENTER LINE <br />WITH BUILDING MANAGEMENT. <br />WORK POLE, MANHOLE, FIBER, STORAGE LOOPS, SPLICE <br />PE <br />PROPERTY LINE <br />CASESAND WHERE INDICATED BY PROJECT MANAGER. TAGS <br />S. <br />THE PROJECT MANAGER IS TO BE NOTIFIED BY THE CONTRACTOR 24 HOURS PRIOR TO <br />NEED TO BE PLACED SO AS TO BE READ FROM THE GROUND. <br />PG&E <br />PG&E LINE <br />CONSTRUCTION. SEE COMPANY CONTACT LIST FOR CONTACT NAME(s) AND TELEPHONE <br />NUMBER(s). <br />5. <br />CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING <br />cornu <br />COMMUNICATION LINE <br />TENSION. LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM <br />ABBREVIATIONS <br />9. <br />THE PROJECT MANAGER WILL RESERVE THE RIGHTTO INSPECT AT ANYTIME THE WORK BEING <br />PRODUCTS. <br />PERFORMED BYTHE CONTRACTOR. IF PROJECT MANAGER DETERMINES THAT THE WORK IS NOT <br />COMCAST COMCAST <br />PL <br />PROPERTY LINE <br />BEING PERFORMED TO MINIMUM QUALITY STANDARDS, THEN THE CONTRACTOR SHALL PROVIDE <br />6. <br />A 100 FOOT FIBER COIL MUST REMAIN IN ALLVAULTS UNLESS <br />CL CENTER LINE <br />PUE <br />PUBLIC UTILITY EASEMENT <br />REWORKAT HIS OWN COST. <br />OTHERWISE NOTED. <br />(E) EXISTING <br />R/W <br />RIGHT OF WAY <br />(N) NEW <br />BOW <br />BACK OF WALK <br />10. <br />ANY CHANGE IN PROJECT SCOPE, INCLUDING BUT NOT LIMITED TO, CONDUIT LENGTH, CONDUIT <br />7. <br />ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH <br />FOC FACE OF CURB <br />SD <br />EXISTING STORM DRAIN <br />PATH, AERIAL PATH ETC. MUST BE APPROVED BY THE PROJECT MANAGER. <br />WARNING TAPE AND A TRACER WIRE, AT RISER POLES THE <br />MIN MINIMUM <br />SS <br />EXISTING SANITARY SEWER <br />LOCATE WIRE SHALL BE ACCESSIBLE AT THE BASE OF THE RISER. <br />MAX MAXIMUM <br />T <br />EXISTING TELEPHONE <br />11. <br />ALL CORI NG/CONSTRUCTION THAT WILL CAUSE NOISE AND/OR VIBRATION SHALL BE DONE WITHIN <br />D/W DRIVEWAY <br />W <br />EXISTING WATER <br />ALLOWED(9AM-3PM) BUSINESS HOURS. <br />8. <br />ALL RISERS WILL BE CAPPED ATALL TIMES. <br />O/S OFFSET <br />R/R <br />REMOVAL/REPAIR <br />12. <br />ANY AND ALL UNDERGROUND UTILITIES ENCOUNTERED ARE THE RESPONSIBILITY OF THE <br />9. <br />ALL FIBER SHALL BE MARKED AS TO DIRECTION IN EACH VAULT. <br />SYMBOLS <br />CONTRACTOR TO LOCATE, PROTECT. AND REPAIR, IF DAMAGED. <br />RED-NORTH, GREEN-SOUTH, YELLOW-EAST, AND <br />BLUE-WEST, DO NOT TAPE FIBER CABLES TOGETHER IN RISER. <br />NEW COMCAST POWER SUPPLY <br />Q TRANSFORMER <br />13. <br />ALL FOOTAGESARE BASED ON FIELD GATHERED MEASUREMENTS, AS SUCH SOME VARIANCE <br />® <br />NEW COMCAST LOW PROFILE <br />SHOULD BE ANTICIPATED. ADJUST AS NEEDED. <br />m 8 <br />STREET LIGHT <br />14. <br />ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36" MINIMUM COVER. SITE HAS POTENTIAL FOR <br />POWER SUPPLY W/ METER <br />ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDE THE MINIMUM COVER, IN CASES WHERE <br />DISCLAIMER: <br />TRAFFIC SIGNAL COMBINATION <br />THE MINIMUM COVER CANNOT BE ACHIEVED, THE CONDUIT SHALL BE PLACED IN ASCH 40 EMT SLEEVE <br />D <br />NEW COMCAST VAULT <br />OR APPROVED EQUIVALENT. <br />FIRE HYDRANT <br />1. <br />IT IS THE RESPONSIBILITY OF THE CONSTRUCTION CONSTRUCTOR <br />m0 <br />NEW COMCAST PEDESTAL <br />15. <br />WATER,SEWER, STORM SEWER AND EASEMENT LOCATIONS ARE BASED OFF OF CITY MAPS, <br />TO VERIFY ALL RIGHT OF WAY BEFORE CONSTRUCTION IS TO <br />& MONUMENT <br />NOT FIELD VERIFIED. <br />BEGIN. NO UNDERGROUND INSTALLATION REPRESENTED WITHIN <br />® <br />THESE PLAN SHEETS IS PROPOSED OUTSIDE OF THE RIGHT OF <br />BORE PIT <br />16. <br />BORING OFAC PAVING IS REQUIREDATALL LOCATIONSAS INDICATED ON PLANS. <br />WAY. <br />® CATCH BASIN <br />®' <br />NEW RISERATTACHED TO POLE <br />17. <br />AT NO TIMES SHALL CURBS, GUTTERSOR HANDICAP BE DISTURBED. <br />2. <br />THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARYAND <br />STORM DRAIN MANHOLE <br />WILL/MAY VARY ONCE UTILITIES HAVE <br />® <br />EXISTING POLE <br />18. <br />DOOR HANGERS ARE TO BE PLACED A MINIMUM OF 72 HOURS PRIOR TO START OF CONSTRUCTION. <br />BEEN FIELD LOCATED. <br />Ow WATER MANHOLE <br />(� <br />EXISTING COMCAST VAULT <br />19, <br />PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PLACE MESSAGE BOARDS STATING <br />3. <br />ANCHORING FOR THE AERIAL CONSTRUCTION IS TYPICALLY <br />LANE CLOSURES, AND DELAYSA WEEK IN ADVANCE, LOCATION OF THE MESSAGE BOARD SHALL BE <br />DETERMINED DURING CONSTRUCTION AND IS COLLECTED IN THE <br />© SANITARY SEWER MANHOLE <br />COORDINATE WITH THE CITY INSPECTORAT THE PRE-CONSTRUCTION MEETING. <br />AS-BUILT PHASE. <br />® <br />EXISTING COMCAST PEDESTAL <br />co SEWER CLEAN OUT <br />20. <br />LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT. ATA TIME. FOR SAFETY PURPOSES THERE <br />0 <br />EXISTING IRRIGATION VAULT <br />SHALL BE ONLY ONE CLOSURE ATA TIME ALONG S EL DORADO ST & E MATHEWS RD. MORE FLAGGERS <br />OE ELECTRIC MANHOLE <br />WILL BE NECESSARY TO HELP VEHICLES AND PEDESTRIANS IN THE WORK ZONES DURING <br />ED <br />EXISTING UTILITY VAULT/PEDESTAL <br />THE LANE CLOSURES. <br />D UNIDENTIFIED MANHOLE <br />D� <br />GAS/WATER VALVE <br />WATER METER <br />® <br />TREE/BUSHES <br />© GAS METER <br />THIS IS AN <br />COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIALmm <br />IMPORTANT NOTICE <br />SEFNCO <br />a.0on Pa, <br />con.om,CA,1021 <br />ENG 8(121)40:410 <br />DESIGN: N.PE <br />REV DESCRIPTION <br />DATE <br />Section # 4216/4217 of the Government Code requires a <br />COmmuwCwnoxS <br />�Plann <br />o-'d pimwn.pi n®ng.:0M m Lc m <br />DRAWN BY: SL/RZ <br />0 ISSUE FOR PERMIT <br />04/08/2023 <br />Dig Alert Identification Number to be issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />PROJ # : JB1313351 <br />APPROVED: <br />CALL TOLL FREE <br />CONSTRUCTION TYPE: SPLICING <br />APPROVED: <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />SYSTEM: SJ COUNTY <br />APPROVED: <br />1-800-227-2600 <br />NODE: <br />SHEET: <br />2 0F 32 <br />